ZSWJ, PSWJ type water jet vacuum unit
Type Gas Transfer Pump Brand King Model ZSWJ
Product details
type Gas transfer pump brand The Golden Emperor model ZSWJ, PSWJ type water jet vacuum unit
material cast iron Drive Type electric


1、 ZSWJ, PSWJ type water jet vacuum unit application characteristics:
ZSWJ and PSWJ water jet vacuum units are widely used and effective vacuum acquisition equipment in various industries. Its characteristics include: simple structure, reliable operation, no mechanical moving parts, low noise, long service life, easy management and maintenance, especially suitable for vacuum processes as mass transfer and chemical mixing reaction equipment to extract harmful gases and dust. ZSWJ and PSWJ water jet vacuum units use different materials and are suitable for different occasions. They are widely used in vacuum absorption, vacuum crystallization, vacuum concentration, vacuum drying, vacuum distillation, vacuum conveying, and other fields such as chemical, pharmaceutical, food, printing and dyeing, environmental protection, and light industry.
2、 The working principle of ZSWJ and PSWJ water jet vacuum units:
The ZSWJ and PSWJ water jet vacuum units utilize fluid to transfer energy and mass, without any mechanical moving parts. They consist of three parts: nozzle, suction chamber, and expansion tube. The working fluid with a certain pressure is ejected at high speed through the nozzle, and through energy conversion, a vacuum is formed in the outlet area of the nozzle, thereby attracting the pumped medium out. The two streams of medium are mixed in the expansion tube and finally discharged at slightly higher than atmospheric pressure. Due to the working medium being water and limited by saturated steam pressure, the ultimate vacuum of the first stage water jet vacuum pump can only reach 23mmHg (3066pa).
3、 ZSWJ, PSWJ type water jet vacuum unit model description:
P
SWJ-160
Z
P: Long throat Z: Short throat
S:水喷射泵
WJ: Horizontal Unit
160: Maximum pumping volume m3/h
4、 ZSWJ, PSWJ type water jet vacuum unit material:
1. The water jet vacuum pump and centrifugal pump are made of cast iron.
2. The circulating water tank, air chamber, and fittings are made of carbon steel.
5、 Technical parameters of ZSWJ and PSWJ water jet vacuum units:
Measurement conditions: working water temperature of 25 ° C, standard atmospheric pressure of 760mmHg

Model number

Absolute pressure

MmHg

Maximum extraction volume

m3/h

Equipped with centrifugal water pump

Weight

Kg

External dimensions

Length X Width X Height (m)

LXWXH

Model number

Power

PSWJ-5 23 5 ISW25-125 0.75 152 1.0X0.6X0.8
PSWJ-10 23 10 ISW40-125(I) 1.1 208 1.0X0.8X0.8
PSWJ-30 23 30 ISW40-160 2.2 422 1.6X0.95X1.3
PSWJ-40 23 40 ISW50-160 3 457 1.8X0.85X1.4
ZSWJ-50 23 50 ISW50-160(I) 4 680 1.9X0.95X1.6
PSWJ-80 23 80 ISW80-160A 5.5 720 2.26X1.2X1.75
ZSWJ-110 23 110 ISW80-160 7.5 859 2.26X1.0X1.87
PSWJ-120 23 120 ISW80-160A 5.5 832 2.26X1.0X1.75
ZSWJ-130 23 130 ISW80-160 7.5 838 2.26X1.0X1.75
PSWJ-160 23 160 ISW80-160 7.5 832 2.26X1.1X1.75
PSWJ-230 23 230 ISW100-160A 11 997 2.65X1.4X1.9
PSWJ-280 23 280 ISW100-160 15 1002 2.65X1.4X1.9
PSWJ-320 23 320 ISW100-160 15 1020 2.65X1.4X1.9
PSWJ-400 23 400 ISW150-250 18.5 1350 3.2X1.4X2.0
PSWJ-500 150 500 ISW150-250 18.5 1350 3.2X1.4X2.3
PSWJ-700 23 700 ISW150-315A 22 1600 3.9X1.4X2.3
PSWJ-800 150 800 ISW150-315A 22 1600 3.9X1.4X2.3

6、 Instructions for using ZSWJ and PSWJ water jet vacuum units:
1. The equipment should be placed indoors as much as possible. If it is placed outdoors, a sunshade and rainproof canopy should be built to avoid direct sunlight and rain, and shorten the service life of the equipment.
2. Water jet pumps can be installed at low or high positions, and can be installed vertically or horizontally. The flange connection should be sealed and not leak. A 3mm rubber plate should be placed between the flanges, and its inner diameter should not be smaller than the flange diameter.
3. When installed vertically, the outlet of the water jet pump must be connected to a straight pipe with the same specifications as the outlet flange diameter, about 1 meter long. The tail pipe of the horizontal unit has already been connected when it leaves the factory.
4. The unit should be placed on a concrete floor, and the connecting pipeline between the suction port and the container to be pumped should be as short as possible. The diameter of the pipeline should not be smaller than the specification of the suction port, otherwise it will affect the pumping volume.
5. During the operation of the unit, the centrifugal pump and the suction of high-temperature medium can cause the working water temperature to rise and reduce the working vacuum degree. Cooling water should be continuously injected for replacement, and cooling plates or tube condensers can also be installed in the water tank for cooling.