Zhaoqing Automation Instrument Co., Ltd
Home>Products>XM series microcomputer temperature controller
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    64 District, Dinghu Avenue, Zhaoqing City, Guangdong Province
Contact Now
XM series microcomputer temperature controller
XM-900温控器 ,XM-900.101, XM-900.201, XM-900.301
Product details

characteristic:

1. Universal input, users can select 56 different input signals such as thermocouples, thermal resistors, and linear signals through panel buttons.

2. Self tuning PID and PID control functions.

3. Manual/automatic disturbance free switching function.

4. The input and output are completely optically isolated.

5. PV and SV value display function.

6. Surface Mount Technology (SMT) process.

7. RS485 communication function.

Main technical indicators:

1. Input thermocouples: K, J, E, T, S, R, B, W, U, various scale marks; Thermal resistance; DPT100。

Linear signals: 4-20mA, 0-20mA, 1-5V, 0-5V

2. Output relay contact: 3A/220V, electrical life: over 100000 times (under rated load), working cycle of 15s.

Solid state relay SSR voltage pulse output: 0-24VDC, ON: 24V, OFF: 0V, with a working cycle of 1 second.

Linear signal: 4-20mA, 0-20mA, 0-5V

3. Control mode: PID, P, PI, PD, ON/OF (P=0)

Setting range: proportional band P: 0~200.0%, integration time: 0~3600s, differentiation time: 0~900s.

4. Precision control accuracy: ± 1 ℃, measurement accuracy: ± 0.54% FC; resolution: 14 bits; Sampling period: 0.5s.

5. Other operating environments: 0 ℃~50 ℃, 50~85RH; insulation resistance>20M Ω (500VDC), insulation strength: 1500VAC/lmin.

Model specifications:

Model marking method: XM □□□ - □□□□ - □□
XM Mouth mouth mouth mouth - opening opening opening opening -
series
code
Width x Height
Main control output 1 Main control output 2 ALARM IN input
Transfer output communication

900—96×96
800—48×96
700—72×72
600—96×48
400—48×48

0- No control
1- Contact points of electromechanical circuit breakers
2- Trigger solid-state relay voltage pulse from 0 to 24V
3—DC4~20mA
0- No control
1- Contact points of electromechanical circuit breakers
2- Trigger solid-state relay voltage pulse from 0 to 24V
3—DC4~20mA
0- None
1-1 group
2-2 groups
3-3 groups
0-Thermocouple (TC)
1-Thermistor (RT)
2- DC mV
3- DC mA
4-DC0~1V
5-DC0~5V
6-DC0~10V
7-DC1~5V

0- None
1-PV value transmission
2-SV value transmission
0- None
1-RS485

Wiring diagram:

XM-900.101  XM-900.201 XM-900.301


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!