VIP member
XJJ-50 series simply supported beam impact testing machine
The main technical parameters of the XJJ-50 series simply supported beam impact testing machine fully comply with ISO 179, GB/T 1043, GB/T 2612, JB/T
Product details
Product Description:
XJJ-50 series simply supported beamimpact testing machineThe main technical parameters fully comply with ISO 179, GB/T 1043, GB/T 2612, JB/T 8762, and GB4742 standards. By replacing the impact pendulum with different energies and adjusting the jaw seat, various impact tests can be conducted. This machine is a detection instrument with a reasonable structure, beautiful appearance, easy operation, and accurate data, widely used in the fields of hard plastics, fiberglass, reinforced nylon, and so on.
Technical Specifications:
Pendulum energy: 7.5J, 15J, 25J, 50J (standard with one hammer)
Pendulum torque: 7.5J Pendulum PL=3.866Nm 15J Pendulum PL=7.733Nm
25J pendulum PL=12.889Nm 50J pendulum PL=25.777Nm
Scale dial small division value: 1/100
Impact speed: 3.8m/s
Swing angle: 160 °
Distance from the center of the pendulum to the center of the specimen: 380mm
Jaw corner radius: R=1 ± 0.1mm
Blade fillet radius: R=2 ± 0.5mm
Impact blade angle: 30 ± l °
Distance between jaw support lines: 40mm, 60mm, 70mm, 95mm
Pendulum impact energy loss: 0.5%
|
Sample Type
|
Length C
|
Width B
|
Thickness D
|
offset
|
|
I
|
80
|
10
|
4
|
60
|
|
II
|
50
|
6
|
4
|
40
|
|
III
|
120
|
15
|
10
|
70
|
|
IV
|
125
|
13
|
13
|
95
|
(The above parameters are for reference only, and detailed parameters are based on real devices)