The X series process calibrator/calibrator is a high-precision handheld signal measurement/output instrument that can simultaneously measure and output various industrial process signals such as voltage, current, resistance, frequency, thermocouple, thermistor, pulse, etc. Its highest accuracy is ± 0.01% FS.
XThe series process calibrator/calibrator can replace measurement and calibration instruments such as current signal source, voltage signal source, resistance box, electronic potential difference meter, frequency meter, etc. It has an independent dual channel design and can measure and output simultaneously. Built in 90 international temperature scale, capable of bidirectional lookup of thermal resistance and thermocouple.
XThe series process calibrator/calibrator is mainly used for industrial field signal calibration and fault diagnosis; Signal measurement and calibration in aerospace, military, and various research institutes and laboratories; It can also serve as a standard for metrological verification departments.
performance index main models main accessories ·Maximum accuracy: ± 0.01% ·Typical accuracy of external sensor: ± 0.2 ℃ ·Signal measurement/output reset ·24V DC power supply with overcurrent protection ·Voltage measurement/output
|
·Current measurement/output ·24VDC distribution/circuit current measurement ·Pulse counting ·Adjustable amplitude pulse signal output ·Frequency measurement/output ·Resistance measurement/output ·Lead resistance compensation function ·14 types of RTD and TC measurements/outputs |
|
maintenanceDCScardgiveDCSmatchedI/OThe cards include current signal input card, voltage signal input card, thermistor signal input card, level signal input card, pulse quantity input card, and current signal output card, all of which can be usedXSeries process calibrator/Calibrator for fault diagnosis and localization, throughX |
||
Series process calibrator |
/The automatic stepping and ramp output functions of the calibrator can also perform rapid linear testing on the card components.Maintain the isolation barrierX series process calibrator/The calibrator can simulate the output of a two-wire transmitter(4~20)mA |
||
|
/The calibrator can conveniently, quickly, and simply calibrate and maintain the isolation barrier on site.Drive actuatorX series process calibrator/Calibrator supportⅡ |
||
、 |
ⅢThe type of analog current signal output has strong driving capability. By using the analog current output function, it can be used to drive on-site execution structures such as electrical converters, valve positioners, etc.Maintain secondary instrumentsX series process calibrator/Calibrators can conveniently maintain secondary instruments such as recorders and controllers. Supports standard voltage, current, millivoltsRTD |
||
、 |
J/K/T/E/R/S/B/NMeasurement and output of common thermocouple, frequency and other signals.Portable flow integrator calibration combinationA multifunctional process calibrator+A temperature calibrator+A portable flow integrator calibration combination is composed of a loop calibrator, which has three signal outputs and one signal measurement, and meets the requirementsJJG 1003-2005 |