Shenzhen Yijie Instrument Co., Ltd
Home>Products>WeatherLink Live 6100
WeatherLink Live 6100
WeatherLink Live can stream up to eight real-time data from Vantage Pro2 or Vantage Vue sensor kits, sensor transmitters, or other Davis Vantage trans
Product details

WeatherLink Live 6100

6100L

New WeatherLink Live: an intelligent way to stream real-time data

WeatherLink Live can stream up to eight real-time data from Vantage Pro2 or Vantage Vue sensor kits, sensor transmitters, or other Davis Vantage transmitters to any device on the LAN (local area network), and upload the data to WeatherLink.com via Wi Fi. Access data on any connected device on WeatherLink.com, or use the WeatherLink app to access data on your smartphone. Including internal temperature and humidity sensors, as well as a barometer. Compatible with all Vantage Pro2 and Vantage Vue transmitters wirelessly. Including AC adapter and Ethernet cable.

operation temperature 32 ° F to+140 ° F; 0 ° C to+60 ° C
Average Current Consumption 100 mA
peak current 700 mA
Housing material Durable and sturdy ABS plastic
Size (height X width x depth) 7 x 4 x 1.25 inches; 18 X 10 X 3 centimeters
Weight (excluding battery or AC adapter) 0.48 lbs. (0.22 kg)
Spare battery 4 AA (not included)
BATTERY LIFE 5 days
ac adapter 5 VDC,1000 mA
WiFi frequency band 2.4 GHz 802.11b/g/n
Sensor data (internal sensors)
air pressure
Resolution and Units 0.001 "Hg, 0.1 mm, 0.1 hPa, 0.1 mb. (User selectable)
range 16.00 "to 32.50" Hg, 410 to 820 mm Hg, 540 to 1100 hPa or mb
Range of altitude -1500 'to+15300' (-460 m to 4670 m)
Uncorrected reading accuracy ± 0.03 "Hg (± 0.8 mm Hg, ± 1.0 hPa/mb) (at room temperature)
Based on the equation of sea level change altimeter
Equation accuracy ±0.01″ Hg (±0.3 mm Hg, ±0.3 hPa/mb)
Need to improve accuracy ± 10 ′ (3m) to meet the accuracy specifications of the equation
Trend (changes within 3 hours) Change ± 0.06 "(2.0 hPa/mb, 1.5 mm Hg)=rapid
Change ± 0.02 "(0.7hPa/mb, 0.5 mm Hg)=slow
Range of rising and falling trend alarms -0.255 to 0.255 "Hg (-6.5 to 6.5 mm Hg, -8.6 to 8.6 hPa/mb)
update interval 1 minute
internal relative humidity
Resolution and Units 0.1%
range 1 to 100% RH
accuracy ±2%
update interval 1 minute
internal temperature
Resolution and Units Current data: 0.1 °
range +32 ° to+140 ° F (0 ° to+60 ° C)
sensor accuracy ± 0.5 ° F (± 0.3 ° C) (typical)
update interval 1 minute
Wireless communication at meteorological stations
Receiving frequency
mode 868.0 - 868.6 MHz FHSS
ID code available 8
range
sight Up to 1000 feet (300 meters)
pass through a wall 200 to 400 feet (60 to 120 meters)
Share to:
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!