product overview
The medium transported by the WQ engineering sewage pump is normal temperature slurry (less than 40 degrees), with a pH value between 6-8. The magazine content ratio of sewage and sewage submersible pumps is 20%, and the particle size is not greater than 3.5mm. The magazine content ratio of unobstructed submersible pumps is 45%, and the particle size is not greater than 18mm
Product Features
The product is non clogging, anti winding, small in size, compact in structure, and highly efficient. It can pump clean water as well as liquids containing particles and magazines. It has oil leakage, overload, undervoltage, and phase loss alarm systems, effectively protecting safe operation.
application
Widely applicable for the drainage and irrigation of sewage in construction sites, coal mines, metallurgy, printing and dyeing, textiles and other occasions, and can also be used for the drainage and irrigation of clean water.
Model Meaning
For example: WQ9-22-2.2
WQ Engineering Sewage Pump
9-Flow rate (m3/n)
22 Head (m)
2.2- Motor power
Product model
|
Supporting pipe diameter (mm)
|
Maximum external dimensions
|
Speed (r/min)
|
|
Height (mm)
|
Width (mm)
|
|||
WQ12.5-15-1.5 |
50
|
489
|
220
|
2860
|
WQ45-9-2.2 |
80
|
520
|
308
|
2860
|
WQ20-16-2.2 |
65
|
527
|
265
|
2860
|
WQ9-25-2.2 |
50
|
516
|
292
|
2860
|
WQ65-8-3 |
100
|
580
|
356
|
2860
|
WQ25-16-3 |
65
|
537
|
265
|
2860
|
WQ15-28-3 |
50
|
450
|
320
|
2860
|
WQ65-12-4 |
100
|
580
|
356
|
2860
|
WQ40-15-4 |
100
|
547
|
369
|
2860
|
WQ15-35-4 |
50
|
550
|
321
|
2860
|
WQ12-40-4 |
50
|
550
|
322
|
2860
|
WQ15-42-4L |
50
|
|
|
2860
|
WQ65-16-5.5 |
100
|
655
|
340
|
2860
|
WQ40-20-5.5 |
80
|
620
|
361
|
2860
|
WQ18-50-5.5 |
50
|
720
|
456
|
2860
|
WQ45-22-7.5 |
80
|
635
|
293
|
2860
|
WQ40-30-7.5 |
80
|
635
|
293
|
2860
|
WQ20-40-7.5 |
65
|
796
|
314
|
2860
|
Fault phenomenon |
Cause analysis |
Exclusion method |
Insufficient traffic
Or no water will come out |
1. Impeller rotation error 2. Is the valve open and intact 3. The pipeline is blocked 4. Low speed 5. Head too high 6. The density of the pumping medium is relatively high 7. High viscosity of the medium 8. Damaged sealing ring (at the mouth ring) |
1. Adjust the rotation direction of the impeller 2. Check, repair, and eliminate 3. Clean up debris 4. Check electrical equipment and circuits 5. Change the pump or reduce the head 6. Dilute with water to reduce concentration 7. Reduce viscosity 8. Replace |
Unstable operation |
1. Unbalanced impeller 2. Bearing damage |
1. Send to the manufacturer for replacement or calibration 2. Replace the impeller |
The pump cannot start |
1. Lack of phase 2. Impeller stuck 3. Winding, connector or cable open circuit 4. Stator winding burnt out 5. Electrical control malfunction |
1. Check the circuit for repair 2. Remove debris 3. Use an ohmmeter to check and repair 4. Repair and replace the winding 5. Repair or replace |
Excessive current |
1. Low working voltage 2. Pipeline and impeller blockage 3. Transporting liquids that have passed or have high viscosity 4. Using a lift that is too high |
1. Adjust the working voltage 2. Clean the pipeline and replace the winding 3. Change density or viscosity 4. Reduce traffic and increase traffic |
Low insulation resistance |
1. Leakage at the power supply terminal of the cable 2. Cable damage 3. Mechanical seal wear leads to leakage 4. Failure of each O-ring seal 5. The casing is corroded by the medium and leaks water |
1. Tighten the compression nut 2. Replace 3. Replace 4. Replace 5. Repair |