WBL-830Fully automatic surface area and porosity analyzer
WBLSeries of fully automatic surface area and porosity analyzers referenceISO9277、ISO15901International standards andGB-119587According to national standards, based on the principle of static capacity measurement, the adsorption desorption process is tested through mass balance equation, static gas equilibrium, and pressure measurement. The testing process is carried out at liquid nitrogen temperature. After a known amount of gas is filled into the sample tube, it will cause a pressure drop. Therefore, the molar mass of the adsorbed gas at adsorption equilibrium can be calculated. By measuring the equilibrium adsorption capacity, the theoretical model is used to determine the single point and multi-point of the tested sampleBETSpecific surface area,LangmuirSpecific surface area;BJHVolume and area distribution of mesopores and macropores, total pore volume;t―plotMicropore volume and surface area,Dubinin―AstakhovMicroporous distribution,Horvath―KawazoeMicroporous distribution; Density function theory(DFT)And Monte Carlo(MC)Parameters such as aperture distribution model.
Modular pneumatic design
WBLThe series of fully automatic surface area and porosity analyzers introduces the most advanced design concepts in the world today, using a unique modular all stainless steel vacuum gas path design and advanced leak proof and pollution-free measures to ensure the achievement of high vacuum and avoid the disadvantages of easy leakage due to too many connecting pipe joints.
Constant temperature
The independently developed metal Dewar flask, due to its unique internal structure design, can store liquid nitrogen for more than ten days, with almost no loss of liquid nitrogen during the experiment, ensuring a constant temperature of the tested sample while avoiding the defect of fragile and immovable glass Dewar flasks.
High precision sensors
Multiple high-precision sensors and22The position ofADThe conversion device ensures the accuracy of specific surface area and pore size calculations.
Advanced theoretical models
Its advanced density function theory(DFT)And Monte Carlo(MC)The pore size distribution model has established its dominant position in China's specific surface area and porosity analyzer industry, and is also at a leading level internationally.
Automated operation
The adsorption and desorption processes are all computer-controlled and do not require manual operation
Technical features:
1Single point, multi-pointBETSpecific surface area,LangmuirSpecific surface area
2、BJHVolume and area distribution of mesopores and macropores, total pore volume
3、t―plotMicropore volume and surface area,
Dubinin―AstakhovMicroporous distribution,
Horvath―KawazoeMicro pore distribution
4Density Function Theory(DFT)And Monte Carlo(MC)Aperture distribution model
Output report:
Direct printing andEXCELOutput adsorption desorption isothermsBETSpecific surface areaLangmuirSpecific surface areat-plotMicro pore volumeBJHPore volume, pore area, total pore volume, total pore areaDbinin-Astakhov、Horvath-KawazoeMicroporous distribution,NLDFT/GCMCPore distribution,Overview report.
Application scope:
Research and product testing of various materials, including measuring zeolites, molecular sieves, silica, alumina, soil, clay, catalysts, organic metal compound frameworks, and other materials
model parameter |
WBL-810 |
WBL-820 |
WBL-830 |
Specific surface area |
0.01㎡/gUp to no limit |
0.01㎡/gUp to no limit |
0.01㎡/gUp to no limit |
Aperture analysis range |
3.5to5000angstrom |
3.5to5000angstrom |
3.5to5000angstrom |
Testing principle |
Low temperature nitrogen physical adsorption (Static capacity method) |
Low temperature nitrogen physical adsorption (Static capacity method) |
Low temperature nitrogen physical adsorption (Static capacity method) |
adsorption |
nitrogen |
nitrogen |
nitrogen |
P/P0range |
1×10-6―0.995 |
1×10-6―0.995 |
1×10-6―0.995 |
Pressure measurement |
Imported absolute pressure sensor0-133KPa, accuracy0.12%,3only |
Imported absolute pressure sensor0-133KPa, accuracy0.12%,4only |
Imported absolute pressure sensor0133KPa, accuracy0.12%,6only |
temperature measurement |
PT-100 ,accuracy 0.1℃ |
PT-100 ,accuracy 0.1℃ |
PT-100 ,accuracy 0.1℃ |
Dewar flask |
2L,duration80hour |
2L,duration80hour |
2L,duration80hour |
vacuum pump |
mechanical pump |
mechanical pump |
mechanical pump |
Ultimate vacuum |
1.0x10-4 Torr |
1.0x10-4 Torr |
1.0x10-4 Torr |
measuring software |
adsorption/Determination of desorption isotherm |
adsorption/Determination of desorption isotherm |
adsorption/Determination of desorption isotherm |
Instrument dimensions |
700 X 700 X 800mm |
700 X 700 X 800mm |
700 X 700 X 800mm |
Simultaneously measure the number of samples |
1Number of samples processed3individual |
2Number of samples processed3individual |
3Number of samples processed3individual |