Ultra pure water machine laboratory
The main performance characteristics of UPA series ultrapure water machine laboratory are:
Product details

UPA series ultrapure water machineUltra pure water machine laboratory

UPA seriesUltra pure water machine laboratoryMain performance characteristics

  • 5.1-inch large screen LCD Chinese display, real-time display of operating status
  • Water quality and temperature display for inlet, RO membrane, and UP water channels, achieving online monitoring
  • Using three pumps for operation, with regular automatic circulation to maintain stable water quality at all times
  • Secondary reverse osmosis design effectively extends the service life of ultrapure water packs
  • Chinese and English language selection function, convenient for language usage habits
  • Pre treatment, RO membrane, UV lamp, and ultrapure water package lifespan can be set arbitrarily, displaying consumable usage and remaining time
  • Can automatically start and shut down the circulation system, extending the lifespan of the ultrapure water package
  • Automatic reminder of consumables expiration to avoid water quality deterioration
  • Set password protection function in the system to prevent unauthorized changes to data
  • Timed and quantitative water intake function
  • Standard one click disinfection function component, realizing rapid disinfection of RO membrane, circulation pipeline, and water tank, ensuring extremely low system pollution level
  • RS-232 communication module, can be connected to a printer to print water quality reports (optional)
  • All plastic shell, rusted

UPA seriesadvantage

  • Online monitoring system water production animation display
  • The automatic circulation function maintains water quality at all times
  • Online display of inlet and RO water quality
  • Ultra pure water quality setting: If the water quality of ultra pure water is lower than the set value, it will automatically trigger an alarm if there is no water output, so there is no need to worry about exceeding the standard for laboratory water
  • The TDS of the incoming water quality is set to trigger an alarm for exceeding the standard and automatically shut down, effectively protecting the host and extending the lifespan of consumables
  • Password protection function
  • Replace the reverse osmosis membrane reminder function
  • Reminder for replacing resin columns
  • Water free protection

Main technical specifications and applicable objects of UPA series ultrapure water machine

model

A-series - I-10/20
Basic application type

A-series II-10/20
Heat source analysis type

A-series II-10/20
Ultra low organic matter analysis type

B-series - I-10/20
Basic application type

40/60/80/100Large capacity floor standing

Source water

Urban tap water TDS < 200ppm, water pressure > 0.1MPa

Water production capacity

10/20 L/H

40/60/80/100L/H

Instant water intake

Pure water 1.5L/min Ultra pure water 1.2L/min (with UF model configured for slightly slower flow rate)

RO effluent conductivity

2~10μs/cm

UP water and electricity outputResistancerate

18.2MΩ· cm@25 ℃

18.2MΩ· cm@25 ℃

18.2MΩ· cm@25 ℃

18.2MΩ· cm@25 ℃

18.2MΩ· cm@25 ℃

Total Organic Carbon (TOC)

TOC<10ppb

TOC<10ppb

TOC<5ppb

TOC<30ppb

TOC<5~30ppb

microorganism

<1CFU/ml

Micro particulate matter

<1/ml(>0.22um)

heavy metal ion

<0.1ppb

<0.1ppb

<0.1ppb

<0.2ppb

<0.1~0.2ppb

heat source

<0.01Eu/ml

---

--

<0.01Eum/ml

External dimensions/weight

400*490*550mm/35kg

350*540*880mm/45kg

Applicable objects

Environmental monitoring, drug testing institute
Quality Inspection Institute, Agricultural Inspection Institute
Health and epidemic prevention, petrochemical industry
Food spices, epidemic control center
Standard laboratories for scientific research in universities

Atomic absorption (AA)
Atomic Fluorescence Spectroscopy (AFS)
Atomic Emission Spectroscopy (AES)
Ion Chromatography (IC)
Mass spectrometry analysis (MC)
Plasma Emission Spectroscopy (ICP)

Liquid chromatography, gas chromatography, amino acid analysis, biotechnology, life sciences, Hitachi/Olympus biochemical analyzer matching

Gene research, tissue culture, animal and plant cell culture, capillary electrophoresis, in vitro fertilization, development of biochips, renal dialysis

Workshops or university experimental buildings that extensively use ultrapure water for semiconductor components, integrated circuit development, circuit board printing, etc

Note: 1. The inlet water quality will affect the outlet water quality and the service life of the filter column.

When the quality of the source water is poor (* TDS>200PPM), the RO pure water quality will drop to over 10us/cm.