technical parameter: |
◆ Model/Specification
Model number |
Action limit (millimeters) |
Setting method |
Installation method |
UQK-01B |
10 |
Not adjustable |
level |
UQK-02B |
25-550 |
Adjustable levels |
level |
UQK-03B |
8-1000 |
Stepless adjustable |
vertical |
UQK-01B-N |
10 |
Not adjustable |
level |
UQK-01B-T |
10 |
Not adjustable |
vertical |
UQK-04B |
10 |
Not adjustable |
level |
◆ Nominal pressure: 4.0MPa
◆ Environmental temperature:- 40℃~85℃
◆ Working temperature: ≤ 150℃
Contact capacity: AC 220V 220VA
DC 100V 150W
◆ Medium density: ≥ 0.4g/cm3
◆ Connection method: HG/T20592-2009(A) PN40 DN80 WN/RF
◆ Liquid receiving material: stainless steel (not required to be supplied as 304)
◆ Outgoing interface: M20 × 1.5 (internal)
Explosion proof type: Explosion proof type, with the explosion-proof mark Exd Ⅱ BT4
◆ Protection level: IP65
◆ Explosion proof shell: ZL102 electrostatic spraying