Overview:
|
The UHZX series low-density magnetic float level gauge is designed to accurately display liquid levels by increasing the buoyancy of low-density media by thickening the float tube and measuring tube. Mainly used for measuring the liquid level of media with a density less than 0.45g/cm3. If a liquid level alarm switch and a remote transmitter are installed on the instrument, remote control, automatic detection, and recording can be achieved.
| Main technical parameters: |
◆ Operating pressure:- 0.1~32.0MPa
Operating temperature: 0~450 ℃
Measurement range: 300~6000mm (extra long liquid level gauges can also be made according to user needs, and extra long ones can be made in sections due to inconvenient transportation.)
◆ Medium density: 0.45~2.0g/cm3
◆ Medium density difference: ≥ 0.15g/cm3
Accuracy: ± 10mm
◆ Connection flange standard: HG/T20592-2009 DN20, DN150 (for top mounted)
Designated by the user (various standard flanges such as GB, HGJ, ANSI, SH, DIN, JIS, etc. can be made according to user requirements)
| Usage conditions: |
|
model |
Structural characteristics |
Applicable conditions |
Liquid receiving material |
Installation form | ||
|
Operating temperature ℃ |
Operating pressure MPa |
Medium density g/cm3 | ||||
|
UHZS |
Dual display type |
0~450 |
≤32.0 | 0.45~2.0 |
stainless steel |
Side by side |
|
0~450 |
≤32.0 | 0.45~2.0 | ||||
| UHZS-7 |
Side top mounted dual display type |
stainless steel | Side top installation | |||
| Structural schematic diagram: |


Overview: