Thermo TSQ ™ 9000 triple quadrupole gas chromatography-mass spectrometry
Thermo Scientific ™ TSQ ™ The 9000 triple quadrupole GC-MS/MS system meets your routine laboratory analysis needs,. Provide high sensitivity for mor
Product details
Product Introduction
Thermo Scientific ™ TSQ ™ 9000 triple quadrupole gas chromatography-mass spectrometry GC-MS/MS
Each
Over time, the daily analysis of stable experiences meets regulatory requirements.
continuous operationAdopting NeverVent ™ technologyimprove
Instrument productivity. By using a vacuum lock (VPI) and ExtractaBrite ion source, as well as a new V-Lock source plugin, the mass spectrometer can perform routine maintenance operations such as cleaning the ion source and replacing the chromatography column without the need for exhaust.
The designed electronic ion (AEI) source is durable even in the face of complex matrices. The new AEI source helps to easily face challenging applications and can alleviate the pressure of the matrix on the analysis system by reducing the concentration steps in sample preparation.
Easy to use
Reduce user interaction with the instrument and maintain expected and consistent response over time using the new and intuitive SmartTune tuning tool.
Accelerate and facilitate method development using AutoSIM and Time SIM (t-SIM) tools.
high sensitivity
The sensitivity and durability of the new AEI ion source enable efficient ionization of analytes and effective focusing of ion beams.
|
|
The system meets your routine laboratory analysis needs,. Provide high sensitivity for more routine analysis. Having stable system durability and reducing maintenance cycles. Develop and operate powerful reporting tools through technology and flexible methods to achieve stable productivity of instruments. Obtain expected results based on easy-to-use daily workflow. | Item number | Unit specifications | describeunit price | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
(CNY) | TSQ9K-VPI | Each |
Scalable GC-MS/MS platform with multiple configuration options
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Over time, the daily analysis of stable experiences meets regulatory requirements.
continuous operationAdopting NeverVent ™ technologyimprove
Instrument productivity. By using a vacuum lock (VPI) and ExtractaBrite ion source, as well as a new V-Lock source plugin, the mass spectrometer can perform routine maintenance operations such as cleaning the ion source and replacing the chromatography column without the need for exhaust.
The designed electronic ion (AEI) source is durable even in the face of complex matrices. The new AEI source helps to easily face challenging applications and can alleviate the pressure of the matrix on the analysis system by reducing the concentration steps in sample preparation.
Easy to use
Reduce user interaction with the instrument and maintain expected and consistent response over time using the new and intuitive SmartTune tuning tool.
Accelerate and facilitate method development using AutoSIM and Time SIM (t-SIM) tools.
high sensitivity
The sensitivity and durability of the new AEI ion source enable efficient ionization of analytes and effective focusing of ion beams.
Upgrade at any time