Provide monitoring of parameters such as flue gas flow rate, pressure, and temperature, and adopt special design to improve product stability and accuracy for high temperature, high dust, and high corrosion flue gas environments. Pitot tube measurement principle, automatic dust cleaning and blockage prevention, flow coefficient compensation, automatic blowback design, multiple measurement parameters, installation accessories, calibration and adjustment methods to choose from.
project |
Specifications |
Flow rate range |
Measurement principle of 0-40 m/s pitot tube method |
Pressure range |
-2500Pa ~ +2500Pa |
Temperature range |
0~300 ℃ (customizable) |
output signal |
4~20mA |
Working temperature range |
-20℃ ~ +50℃ |
equipment |
Display operation unit, sampling unit, measurement and control unit
Anti blowing interface: OD6/4mm card sleeve
|
Probe rod |
Special wear-resistant and anti-corrosion material |
Backblowing and control unit |
Reverse blowing air is instrument air, pressure range: 4-8Bar, reverse blowing interface: OD6/4mm card sleeve |
LCD display operating unit |
Directly adjust parameters such as flow velocity field coefficient and blowback interval time |
power supply |
220V AC |
Zero calibration function |
manual |
Shell protection level |
IP65 |
Installation method |
DN65 flange connection (optional ANSI 150) |
Install the attachment |
Four sets of filters, mounting flanges, flange gaskets, and installation bolts |
Zhejiang Sanxing Thermal Power Co., Ltd. Smoke Online Monitoring System
Zhejiang Tianlan Company Yongtai Project Smoke Online Monitoring System
Hangzhou Fuyang Gaoqiao Thermal Power Co., Ltd. Boiler desulfurization flue gas online monitoring system
Fuyang Shenneng Solid Waste Environmental Protection Recycling Co., Ltd. Smoke Online Monitoring System
Fuyang Yongtai Thermal Power Co., Ltd. Smoke Online Monitoring System
Fuyang Fuchunjiang Thermal Power Smoke Online Monitoring System
…….