Technical parameters of high and low temperature impact boxDetailed Introduction
Technical parameters of high and low temperature impact boxDetailed IntroductionFreezing system | ||
condenser |
Fin type attached platform dispersing hot air fan |
|
evaporator |
Fin type multi-stage automatic load capacity adjustment |
|
expansion valve |
Danfoss components from Denmark |
|
compressor |
*French "Taikang" brand fully enclosed compressor |
|
refrigerant |
Imported environmentally friendly refrigerant R404A from the United States |
|
Refrigeration auxiliary components |
Desiccant (Denmark), oil separator (USA), refrigerant window (Denmark), solenoid valve (Japan), filter (Japan), pressure controller (Korea), shut-off valve (Italy) and other refrigeration accessories are all imported parts.thermal shock chamber |
|
Detailed product introduction | ||
The high and low temperature impact box is a testing equipment used in the metal, plastic, rubber, electronics and other material industries to test material structures or composite materials. It can withstand continuous temperature and extremely low temperature environments in an instant, and can detect chemical changes or physical damage caused by thermal expansion and contraction of the sample in the shortest possible time. | ||
test method | ||
GB/T2423.1.2, GB/T10592-2008, GJB150.3 High and Low Temperature Impact Test Chamber. |
Detailed introduction of product structure | ||
inside dimensions |
W × H × D: 400 × 400 × 400 (mm) 64 liters |
|
Carton size |
W×H×D :1700×1900×2000(mm) |
|
Inner box material |
Mirror stainless steel plate (SUS # 304) |
|
External material |
Sandgrain stainless steel plate (SUS # 304) |
|
Insulation material |
a. High temperature tank: Aluminum silicate insulation cotton b. Low temperature tank: High density PU foam |
|
Box door |
Single panel doors for upper and lower boxes, left opening a. Embedded flat handle b. Rear button: SUS # 304 c. Silicone foam strip |
|
Sample placement rack |
Stainless steel SUS # 304 inner box |
|
Heating system |
Fin type heat dissipation tube shaped stainless steel electric heater 1. High temperature slot 6 KW 2. Low temperature slot 3.5 KW |
|
Air circulation system |
1. Two 1HP motors 2. Stainless steel extended shaft 3. Multi blade fan (SIROCCO FAN) 4. Specially designed fan forced air circulation system |
|
Detailed introduction of technical parameters | ||
Temperature range of the test tank |
-65℃— +200℃ |
|
High temperature tank temperature setting range |
+60℃— +220℃ |
|
Heating time of high temperature tank |
RT (room temperature) --+150 ℃ ≤ 40min (at room temperature of+10-+30 ℃) |
|
Low temperature tank temperature setting range |
-80℃-- -10℃ |
|
Cooling time of low-temperature tank |
RT (room temperature) -80 ℃ ≤ 85min (at room temperature of+10-+30 ℃) |
|
temperature fluctuation |
±1.0℃ |
|
temperature uniformity |
±2.0℃ |
|
Impact recovery time |