VIP member
TH110 portable Leeb hardness tester
TH110 portable Leeb hardness tester
Product details
TH110 portable Leeb hardness tester
|
☆ Measurement range: (170-960)HLD
|
☆ Operating frequency: 1
|
☆ Detection accuracy: ± 0.5% (HLD=800)
|
☆ Indication error: 0.8% (HLD=800)
|
Product Introduction
----------------------------------------------------------------------
TH110: Fully functional and outstanding performanceTH110The portable Leeb hardness tester, based on the Leeb hardness measurement principle, can conveniently and quickly measure various metal materials. While displaying the hardness measurement value immediately, it can freely switch between different hardness standards, pre-set tolerance limits, and automatically sound an alarm if it exceeds the range. Relying on stable low-power IC integrated circuits, fully Chinese display, simple and convenient menu based operation, and seven types of irregular impact devices. External USB drive, large capacity storage. 50 hours of standby time. Especially suitable for work sites and field operations. | ||
nAccording to the principle of Leeb hardness measurement, various metal materials can be tested. nLarge screen EL backlit display, fully Chinese menu style operating interface, convenient for reading and use. nIt can store up to 270 sets of hardness measurement data, each set of data including average value, impact direction, frequency, material, hardness system, and other information. nThe seven types of impact devices do not require calibration and have good compatibility with automatic recognition, and come with measurement indication calibration function. nSupports measuring multiple hardness systems, displaying and converting immediately: Brinell HB, Rockwell HRC, Vickers HV, Shore HS, and three strength values. nSupporting "Steel" materials, when testing "Steel" specimens with D/DC type impact devices, the HB value can be directly read without the need for manual table lookup. The upper and lower limits of the hardness value can be pre-set, and an automatic alarm will be triggered if it exceeds the range, which is convenient for users to test in batches. nAdopting a large screen 128 × 64 dot matrix LCD display, the information is rich and intuitive. nFull Chinese display, menu style operation, simple and convenient operation. nEquipped with EL backlight display, convenient for use in low light environments. nThere is a USB interface that allows for convenient and quick storage of data onto a USB drive. nThe instrument is compact, portable, and highly reliable, suitable for harsh operating environments. nResistance to vibration, impact, and electromagnetic interference. |
||
Display interface | ||
Seven types of irregular impact devices |
||
Type of impact device | ||
The Leeb hardness is represented by the ratio of the impact velocity VA and rebound velocity VB at a distance of 1mm from the surface of the specimen when impacted by a certain quality of impact body under the action of spring force. Using electromagnetic principles, the permanent magnet inside the impact body generates an induced voltage in the coil of the impact device, which is proportional to the velocity of the impact body. The formula is as follows: HL=1000 × V B/VA |
||
Working principle |
performance index | |
Measurement direction Supports 360o (vertical downward, oblique downward, horizontal, oblique upward, vertical upward) |
|
Detection range (170-960)HLD,(17.9-69.5)HRC,(19-683)HB,(80-1042)HV,(30.6-102.6)HS, (59.1-88)HRA, (13.5-101.7)HRB |
|
Hardness standard Leeb (HL), Brinell (HB), Rockwell B (HRB), Rockwell C (HRC), Rockwell A (HRA), Vickers (HV), Shaw (HS) |
|
Indication error ±0.5%(HLD=800) |
|
Repeatability of indication values 0.8%(HLD=800) |
|
display | |
High contrast 128x64 dot matrix LCD display, exquisite printed text, numbers, and symbols, high brightness EL backlight | |
storage | |
600 sets of data | |
USB storage Breaking through traditional storage modes, reporting storage anytime, anywhere, without the need for communication software, freeing oneself from cable constraints |
|
Data browsinghave | |
LanguageChinese/English | |
Power Supply | |
Battery1.5V AA battery x2 | |
Low voltage promptYes, there is | |
Automatic shutdownYes, there is | |
working hours Can work continuously for 200 hours (under standard testing conditions) |
|
work environment | |
Operating temperature:- 10-50℃ Storage temperature:- 30℃-60℃ Relative humidity ≤ 90% There is no strong vibration, strong magnetic field, corrosive medium, or severe dust in the surrounding environment. |
|
Standard configuration | |
Instrument host D-type impact device Standard Leeb hardness block Instrument box |
1 unit 1 piece 1 piece 1 set |
Applicable materials | |
Steel and cast steel, alloy tool steel, stainless steel, gray cast iron, ductile iron, cast aluminum alloy, copper zinc alloy (brass), copper tin alloy (bronze), pure copper, forged steel | |
Main application areas | |
Bearings and other components; Failure analysis of pressure vessels, turbine generator sets, and equipment; Heavy duty workpieces; Installed mechanical or permanently assembled components; Workpieces with limited experimental space; Require formal original records of test results; Material differentiation in metal material warehouses; Rapid inspection of multiple measurement locations on large workpieces |
.. Our optional configurations
Serial number | name | quantity | remarks |
1 | Irregular impact device | 7 types | |
2 | Irregular support ring | 12 of them | |
3 | Impact ball head | 2 types | |
4 | Nylon brush B | 1 piece | Used with G-type impact device |
5 | Replace the impact ball head tool | 1 piece |
.. Common material hardness values
Material Science | Hardness system | Impact device | |||||
D/DC | D+15 | C | G | E | DL | ||
Steel and cast steel Steel and cast steel |
HRC | 17.9~68.5 | 19.3~67.9 | 20.0~69.5 | 22.4~70.7 | 20.6~68.2 | |
HRB | 59.6~99.6 | 47.7~99.9 | 37.0~99.9 | ||||
HRA | 59.1~85.8 | 61.7~88.0 | |||||
HB | 127~651 | 80~638 | 80~683 | 90~646 | 83~663 | 81~646 | |
HV | 83~976 | 80~937 | 80~996 | 84~1042 | 80~950 | ||
HS | 32.2~99.5 | 33.3~99.3 | 31.8~102.1 | 35.8~102.6 | 30.6~96.8 | ||
Steel forged steel | HB | 143~650 | |||||
CWT、ST Alloy tool steel |
HRC | 20.4~67.1 | 19.8~68.2 | 20.7~68.2 | 22.6~70.2 | ||
HV | 80~898 | 80~935 | 100~941 | 82~1009 | |||
Stainless steel stainless steel |
HRB | 46.5~101.7 | |||||
HB | 85~655 | ||||||
HV | 85~802 | ||||||
GC. IRON Grey cast iron |
HRC | ||||||
HB | 93~334 | 92~326 | |||||
HV | |||||||
NC、IRON Ductile iron |
HRC | ||||||
HB | 131~387 | 127~364 | |||||
HV | |||||||
C.ALUM Cast aluminum alloy |
HB | 19~164 | 23~210 | 32~168 | |||
HRB | 23.8~84.6 | 22.7~85.0 | 23.8~85.5 | ||||
BRASS Copper zinc alloy (brass) |
HB | 40~173 | |||||
HRB | 13.5~95.3 | ||||||
BRONZE Copper Tin Alloy (Bronze) | HB | 60~290 | |||||
COPPER Pure Copper | HB | 45~315 |
..Technical parameters of irregular impact device
Irregular impact device | DC(D)/DL | D+15 | C | G | E | ||
Impact energy Impact mass |
11mJ 5.5g/7.2g |
11mJ 7.8g |
2.7mJ 3.0g |
90mJ 20.0g |
11mJ 5.5g |
||
Ball head hardness: Ball head diameter: Ball head material: |
1600HV 3mm Tungsten carbide |
1600HV 3mm Tungsten carbide |
1600HV 3mm Tungsten carbide |
1600HV 5mm Tungsten carbide |
5000HV 3mm diamond |
||
Diameter of impact device: Length of impact device: Weight of impact device: |
20mm 86(147)/ 75mm 50g |
20mm 162mm 80g |
20mm 141mm 75g |
30mm 254mm 250g |
20mm 155mm 80g |
||
Maximum hardness of the specimen | 940HV | 940HV | 1000HV | 650HB | 1200HV | ||
The average surface roughness Ra of the specimen: | 1.6μm | 1.6μm | 0.4μm | 6.3μm | 1.6μm | ||
Minimum weight of test piece: Directly measurable Stable support is required Need for dense coupling |
>5kg 2~5kg 0.05~2kg |
>5kg 2~5kg 0.05~2kg |
>1.5kg 0.5~1.5kg 0.02~0.5kg |
>15kg 5~15kg 0.5~5kg |
>5kg 2~5kg 0.05~2kg |
||
Minimum thickness of test piece Dense coupling Minimum depth of hardened layer |
5mm ≥0.8mm |
5mm ≥0.8mm |
1mm ≥0.2mm |
10mm ≥1.2mm |
5mm ≥0.8mm |
||
Ball indentation size | |||||||
When the hardness is 300HV | Indentation diameter Indentation depth |
0.54mm 24μm |
0.54mm 24μm |
0.38mm 12μm |
1.03mm 53μm |
0.54mm 24μm |
|
When the hardness is 600HV | Indentation diameter Indentation depth |
0.54mm 17μm |
0.54mm 17μm |
0.32mm 8μm |
0.90mm 41μm |
0.54mm 17μm |
|
When the hardness is 800HV | Indentation diameter Indentation depth |
0.35mm 10μm |
0.35mm 10μm |
0.35mm 7μm |
-- -- |
0.35mm 10μm |
|
Scope of application of impact device | DC type measuring hole or cylinder; DL type measurement of slender narrow slots or holes; D-type is used for routine measurement |
The D+15 type contact surface is small and elongated, suitable for measuring grooves or concave surfaces | C-type has low impact force, minimal damage to the tested surface, and does not damage the hardened layer, making it suitable for measuring small lightweight components and surface hardened layers. | G-type measurement of heavy and rough surface castings and forgings | E-type material with extremely high hardness measurement |
Online inquiry