VIP member
TC-6180C Atmospheric/24-hour/TSP Comprehensive Sampler
TC-6180C Atmospheric/24-hour/TSP Comprehensive Sampler Product Introduction: The instrument integrates two channels of atmospheric sampling, two chann
Product details
TC-6180C Atmospheric/24-hour/TSP Comprehensive Sampler
1、 TC-6180C Atmospheric/24-hour/TSP Comprehensive Sampler Product Introduction
The instrument integrates two atmospheric sampling channels, two 24-hour constant temperature and current sampling channels, and one TSP sampling channel, making it versatile and capable of sampling various particulate matter and gas components in the air. Suitable for routine monitoring and environmental evaluation of the atmosphere by relevant departments such as factories, mines, environmental protection, labor, health, scientific research, meteorology, etc.IITC-6180CThe atmospheric/24-hour/TSP comprehensive sampler adopts biao zhun
JJG 956-2013 Atmospheric Sampler
HJ/T 376-2007 "Technical Requirements and Testing Methods for 24-hour Constant Temperature Automatic Continuous Environmental Air Samplers"
HJ2.2-2008 Technical Guidelines for Environmental Impact Assessment - Atmospheric Environment
HJ/T 374-2007 Technical Requirements and Testing Methods for Total Suspended Particle Samplers
JJG 943-2011 "Total Suspended Particle Sampler"
HJ 618-2011 "Determination of PM10 and PM2.5 in ambient air by gravimetric method"
HJ/T 93-2013 "Technical Requirements and Detection Methods for Particulate Matter (PM10 and PM2.5) Samplers in Environmental Air"
Q/0213TWB 001-2014 Enterprise biao zhun
3、 Main features
1. Two atmospheric channels, two 24-hour channels, and one TSP particulate matter sampling channel;
2. The high-speed processor automatically calculates and controls the sampling flow rate, and compensates for flow changes caused by voltage fluctuations and resistance changes;
3. The atmosphere and 24-hour sampling gas path are equipped with anti backflow suction drying bottles to prevent the absorption liquid from being sucked back;
4. Pipeline blockage protection function: During the atmospheric and 24-hour sampling process, if the pipeline is blocked or the load is too high, the system will automatically stop the pump to protect the instrument from damage due to long-term overload. If the load is greater than negative 20kPa for a long time, the protection function will be automatically activated;
5. 24-hour constant temperature sampling: electronic semiconductor dual cooling and rapid heating device, adjustable temperature (15-30) ℃;
6. High performance ultra-low frequency brushless diaphragm pump is used for atmospheric and 24-hour sampling, with a long service life;
7. The atmosphere and 24-hour sampling are connected using red and blue dual color gas path connecting pipes, making it easy and accurate to connect the gas path;
8. Automatically measure ambient atmospheric pressure and temperature, display real-time sampling flow rate, cumulative sampling volume, and standard condition volume;
9. Built in real-time clock, which can pre-set the sampling start time;
10. Timed sampling can be set, with equal intervals for multiple samplings. The number of samplings can be arbitrarily set between 1 and 99 times;
11. The particulate matter sampling adopts an imported DC fan with a continuous operation life of over 20000 hours.
12. The TSP/PM10/PM2.5 sampling head is made of aluminum alloy material and has anti-static adsorption;
13. Power off protection function, automatic sampling of incoming calls;
14. The Chinese LCD screen with automatic contrast adjustment can work normally at minus 30 degrees Celsius;
15. Equipped with a height adjustable triangular bracket;
16. Equipped with RS232 digital communication interface, it can be connected to an external printer for convenient data output.
4、 Technical indicators
| technical indicators | parameter range | resolution | accuracy |
| Atmospheric sampling flow rate | (0.1~1.0)L/min | 0.01L/min | Better than ± 2.5% |
| 24-hour sampling flow | (0.18~0.22)L/min, Constant current at 0.20L/min | 0.1L/min | Better than ± 2.5% |
| Sampling of particulate matter | (60~130)L/min | 0.1L/min | Better than ± 2.0% |
| Traffic repeatability | Better than ± 2.0% | ||
| Traffic stability | Better than ± 2.5% | ||
| Pre measurement pressure | (-20 to 0)kPa | 0.01kPa | Better than ± 2.5% |
| Environmental atmospheric pressure | (70~130)kPa | 0.01kPa | Better than ± 0.2% |
| Single channel air with the largest sampling volume | 9999.99L | 0.01L | Better than ± 2.0% |
| sampling time | 1min~99h59min | 1min | Better than ± 0.2.% |
| The largest volume of particulate matter sampling | 999999.99L | 0.1L | Better than ± 2.0% |
| constant temperature | 23 ℃ (default, other adjustable) | 0.1℃ | Not exceeding ± 1.5 ℃ |
| Timed startup | 24-hour clock | ||
| Equidistant sampling time | Set freely within 99 hours and 59 minutes | ||
| Equal interval sampling frequency | 1 to 99 times | ||
| noise | <55dB(A) | ||
| Overall dimensions (W × D × H) mm | 260×380×300 | ||
| weight | About 8.0kg | ||
| power supply | AC220V±10% 50HZ | ||
| power consumption | <300W | ||
| Sampling head indicators | |||
| PM2.5 cutting characteristics | Da50 = (2.5±0.2)μm 〥g = (1.2±0.1)μm | ||
| PM10 cutting characteristics | Da50 = (10±0.5)μm 〥g = (1.5±0.1)μm | ||
| Entrance speed | 0.3m/s | ||
| b/a | 0.625 | ||
| sampling flow | 100L/min | ||
| Effective filter membrane diameter | Ф80mm | ||
| connector | M20×1.5 | ||
5Packing List
| serial number | name | unit | quantity | Remarks |
| 1 | host | Taiwan | 1 | |
| 2 | Main aluminum box | a | 1 | |
| 3 | TSP sampling head | a | 1 | PM10 and PM2.5 are optional sampling heads |
| 4 | Ø 4.5 × 8 gas path connecting pipe | root | 1 | Red 40cm |
| 5 | Ø 4.5 × 8 gas path connecting pipe | root | 1 | Red 28cm |
| 6 | Ø 4.5 × 8 gas path connecting pipe | root | 1 | Blue 44cm |
| 7 | Ø 4.5 × 8 gas path connecting pipe | root | 1 | Blue 28cm |
| 8 | Ø 4.5 × 8 gas path connecting pipe | root | 1 | Red 22cm |
| 9 | Ø 4.5 × 8 gas path connecting pipe | root | 1 | Red 30cm |
| 10 | Ø 4.5 × 8 gas path connecting pipe | root | 1 | Blue 25cm |
| 11 | Ø 4.5 × 8 gas path connecting pipe | root | 1 | Blue 26cm |
| 12 | Anti reverse suction dryer | a | 4 | |
| 13 | Absorption bottle | a | 4 | |
| 14 | bracket | a | 1 | |
| 15 | power cord | root | 1 | |
| 16 | triangular bracket | a | 1 | |
| 17 | Sampling filter membrane | box | 1 | |
| 18 | Filter membrane clamp box | a | 1 | |
| 19 | Product Manual | copy | 1 | |
| 20 | Product Qualification Certificate | copy | 1 | |
| 21 | Product Warranty Card | copy | 1 |
Online inquiry