Siemens SITRANS FUE380 certified ultrasonic thermal meter flowmeter
The SITRANS FUE380 instrument complies with the thermal measurement standards EN 1434, Level 2 and OIML R752, and the measurement parameters are not affected by operation. The certified flowmeter is named SITRANSFUE380.
SITRANS FUS380 and SITRANS FUE380 have exactly the same technical specifications, with the difference being that FUE380 has an authentication mark.
advantage
In the event of communication power failure, optional battery backup is available
Quick measurement frequency of 20 Hz/0.5 Hz (230 V AC/battery)
Single key operation, direct display
The principle of dual channel measurement can achieve the best accuracy
• Integrated or detachable installation
• Can measure any water quality and have no conductivity requirements
• No pressure drop
• Long term stability
Digital output with photoelectric isolation, convenient for connecting to computers (without potential impact)
• Dynamic measurement range: up to 1:200
• MODBUS RTU/RS 232, RS 485
application
Combining an energy calculator and a pair of temperature sensors, SITRANS FUE380 can be used as part of an energy meter. For this purpose, Siemens provides the energy calculator SITRANS FUE950.
design
Optional integrated or split installation, with a distance of up to 30 meters between the flowmeter and signal converter. When ordering an integrated instrument, the transducer cable is installed properly and ready to use.
The maximum applicable temperature for integrated installation is 120 ° C. The sensor must be isolated to prevent the signal converter from being heated. The signal converter complies with IP67/NEMA 4X/6 protection level.
review
The SITRANS FUE380 has two independently selectable digital output functions.
When placing an order, the pulse output setting can be specified.
If the flowmeter is used as part of a sealed energy delivery instrument system, no further certification is required except for local certification on the flowmeter.
Technical Data SITRANS FUE380
Design a dual channel sensor with flange and integrated transducer for pipeline design, and perform real flow calibration in the factory
Nominal size (welded type) DN 50, 65, 80, 100, 125, 150,200, 250, 300, 350, 400, 500,600, 700, 800,900,1000,1200
Pressure rating PN 16, PN 25, PN 40 EN 1092-1
DN 50~DN 80 copper
DN 100~DN 1200 carbon steel
Pipeline material Carbon Steel EN 1.0345/p235 GH
The transducer design is integrated and welded onto the pipeline
The transducer material is stainless steel AISI 316
Storage -40...+85 ° C
Liquid temperature • Split: 2... 200 ° C
• Integrated: 2... 120 ° C
Protection level sensor connection IP67/NEMA 4X/6
Maximum flow rate DN 100... 800:
• FUS380: 8 m/s
• FUE380: 6 m/s
Enclosure IP67 (NEMA 4X/6) EN 60529 DIN 40050
The ambient temperature is 0 .. 60 °C
Storage temperature -40 degrees Celsius +85 ° C (including battery)
Integrated installation on sensor: up to 120 ° C
Separate installation: up to 30 meters away from the signal converter
Mechanical vibration IEC 68-2-6 varies sinusoidally in all directions by 2 g, 1... 800 Hz
Design glass fiber reinforced polyamide
Power battery: replaceable 3.6V lithium battery pack, 32 Ah
AC power: 87... 265 V AC (50... 60Hz)
Measurement rate battery mode: 0.5 Hz
AC power supply: 20 Hz
Backup mode: 0.5 Hz (in case of AC power failure)
Digital output with two passive outputs, electrically isolated MOS relay type A and B, maximum ± 35 V AC/DC, 50 mA
Maximum pulse frequency 100 Hz
Alarm display channel 1 (F1), channel 2 (F2), low battery display (F5), qs overload (F6), pulse overflow (F7)
The cable length is up to 30 meters between the signal converter and the sensor
EMC • Anti emission interference EN 61000-6-4
Anti noise EN 61000-6-2
Certification EN 1434 and OIML R75 Class 2