Desktop high-speed freeze centrifuges are widely used in clinical medicine, biochemistry, genetic engineering, immunology and other fields. It is an essential instrument used for centrifugal separation in hospitals, research institutions, and universities at all levels.
Main technical performance
1. Microcomputer control, high torque AC variable frequency motor drive, stable operation, low noise, high speed accuracy.
2. Touch panel, programmable operation, host operating parameters can be set according to requirements and automatically stored.
3. Humanized interface, simple and convenient operation.
4. Real time conversion and setting of readings between rpm/RCF, convenient and fast.
5. Equipped with electronic door locks and multiple protection functions such as door cover self-locking, overspeed, and overheating; Automatic fault alarm function, safe and reliable.
6. A ramp up/down rate curve with 9 programs, and ramp up/down time can be set as needed.
Main technical parameters
|
model |
RGL-180T |
|
maximum speed |
18000r/min |
|
Maximum relative centrifugal force |
23755xg |
|
maximum capacity |
100mlx4 |
|
Speed accuracy |
± 30r/min |
|
Time setting range |
1min~9h59min/1min~99min |
|
Temperature setting range |
-20~+40℃ |
|
Temperature control accuracy |
±1℃ |
|
compressor unit |
Imported high-performance compressor unit, environmentally friendly refrigerant R134a |
|
Whole machine noise |
<65dB(A) |
|
power supply |
AC220V 50Hz 15A |
|
Dimensions (LxWxH) |
600mmx470mmx330mm |
|
Outer packaging size (LxWxH) |
720mmx610mmx430mm |
|
Net weight |
50kg |
|
model |
Product Name |
maximum speed |
Maximum relative centrifugal force |
capacity |
Remarks |
|
|
RGL-180T |
High speed refrigerated centrifuge |
18000 |
23755 |
Microcomputer, frequency converter LED |
Host with NO.1 |
|
|
N0.1 |
Angular rotor |
18000 |
22530 |
1.5ml/2.2ml×12 |
choose one of the two |
|
|
NO.2 |
Angular rotor |
16000 |
23755 |
1.5ml/2.2ml×24 |
choose one of the two |
|
|
NO.3 |
Angular rotor |
13000 |
11400 |
5ml×10/12 |
choose one of the two |
|
|
NO.4 |
Horizontal enzyme-linked immunosorbent assay rotor |
3000 |
1400 |
2 × 48 holes |
|
|
|
NO.5 |
Angular rotor |
13000 |
16760 |
0.5ml×36/48 |
choose one of the two |
|
|
Angular rotor |
13000 |
16760 |
10ml×12 |
|
||
|
Angular rotor |
13000 |
16760 |
15ml×8 |
|
||
|
NO.6 |
Angular rotor |
12000 |
13000 |
50ml×6 |
Suitable for round bottom pipes |
|
|
Angular rotor |
12000 |
13000 |
50ml×6 |
Suitable for pointed bottom pipes |
||
|
Angular rotor |
12000 |
13000 |
100ml×4 |
|
||
|
NO.7 |
Horizontal rotor |
6000 |
3200 |
10ml×4 |
|