ST-109 Level 1 Integral Noise Meter
This product complies with JJG-188 Level 1
Supports MICRO SD card
Measurement of digital integration and pulse sound
Dynamic range: 110dB
Large LCD screen with backlight device
There are five testing modes to choose from
Fixed screw holes for tripod
Fully compliant with the International Electrotechnical AssociationIEC 61672-2002 CLASS 1
JJG 188 1level
- environmental condition :temperature 23°C± 5°C,humidity< 80%
- display :Double row display,Maximum display1999
- Display updates :per second1order
- Compliant with standards
IEC 61672-1:2002 Class1 JJG-188-2002 Class 1 CNS NO.7129 IEC60651 : 1979 TYPE 1 IEC60804 : 2000 TYPE 1 ANSI S1.4 : 1983 Type1
- microphone : 1/2Inch polarized condenser microphone
- measuring items : Lxyp ,Lxmax ,Lxmin ,Lxeq ,LAE ,Lcpeak ,RT60
- measuring range :
30dBto130dB (A)
35dBto130dB (C)
40dBto130dB (Z)
- dynamic range : 1 00 dB
- Integral time setting :hand movement, tensecond , onedivide , fivedivide , tendivide , thirtydivide , onehour , eighthour , sixteenhour , twenty-fourhour
- Internal memory capacity : 24C512 × 4 : Maximum number of records>37000
- Micro SDblock : Micro SDMaximum support for cards4GB;37000Pen data memory space approximately300KB
- Maximum peak valueCWeighted measurement range : 70~133 dB
- time weight :Quickly(Fast),Slow speed(Slow),Pulse sound(IMPULSE) ,Peak value(PEAK)Time weighted measurement
- frequency weighting : A/C/Z
- Frequency range :
31.5Hz~8KHz(ST-107)
20Hz~8KHz(ST-107S)
20Hz~16KHz(ST-109)
- DCoutput : 2Vdc/130dB
- ACoutput : 2Vrms/130dB
- Start Time :<10 Second
- power supply : 30hour(AA,3Alkaline battery4The grain)
- ACchangeDCtransformer :INPUT VOLTAGEAC 100V~240V ;Output voltageDC 6V~9V/500mA