1、 Performance characteristics:
1. High precision measurement of electrical parameters such as three-phase voltage, three-phase current, active power, reactive power, apparent power, power factor, frequency, neutral line current, etc
2. Positive and negative active/reactive energy metering
3. Time of use electricity metering, with 4 different rates for 12 time periods
4. Timed meter reading for time-sharing electricity
5. 12-month historical energy data storage
6. Positive/negative/zero sequence current, positive/negative/zero sequence voltage, current imbalance, voltage imbalance
7. Demand function, over limit alarm, event recording
8. Large screen, high-definition LCD display
9. Supports 2-channel RS-485 communication and Modbus RTU protocol
10. Support switch input, switch output, analog transmission output, analog output
11. DC input, power pulse output
12. Wide range AC/DC universal power supply: AC/DC 80V~270V
2、 Technical indicators:
1. Measurement accuracy:
Voltage: Level 0.5 Current: Level 0.5
Active power: Level 0.5 Reactive power: Level 0.5
Frequency: ± 0.02Hz Clock: < 0.5S/d
Active energy: 0.5S level Reactive energy: 1 level
2. Signal input:
Wiring method: three-phase four wire, three-phase three wire
Rated voltage: AC 57.7V, AC 100V, AC 220V, AC 380V Rated current: AC 1A、AC 5A
Overload: Voltage: 1.2 times (continuous), 2 times/1 second (instantaneous)
Current: 1.2 times (continuous), 10 times/5 seconds (instantaneous)
Power consumption: Voltage:< 1VA/phase, current:< 0.4VA/phase
Impedance: Voltage:> 300k Ω, current:< 20mΩ
Frequency: 45-65Hz
3. Auxiliary power supply:
Scope of work: AC/DC 80V~270V Power consumption: < 4VA
4. Functional modules:
Communication interface: Supports 2-channel RS-485 communication, Modbus RTU protocol baud rate: 2400-19200bps, default 9600bps
Switch input: supports 12 channels of dry node input
Switching output: supports 4 relay outputs, capacity: AC 250V/5A,DC 30V/5A
Transmission output: Supports 4-channel analog output: 0/4-20mA or 0-5/10V
DC input: supports 2 analog inputs: 0-20mA
Power pulse output: supports 2-channel power pulse output, constant: 5000 or 20000 imp/kWh (kvarh)
5. Environmental conditions:
Working temperature: -10 ℃~+55 ℃ Environmental temperature:- 25℃~+70℃
Relative humidity: ≤ 93%, non corrosive gas location altitude: ≤ 2500m
6. Safety:
Insulation resistance:> 100M Ω AC withstand voltage: AC 2kV
7. Electromagnetic compatibility performance:
Electrostatic discharge: Level 4 rapid transient pulse train: Level 4 surge (impact): Level 4
8. External dimensions:
Frame size (mm) 120 × 120
Hole size (mm) 111 × 111