SJD series simple measuring instruments
Electric power metering instruments are suitable for low-voltage measurement of AC parameters and active and reactive power. They have the characteris
Product details

performancecharacteristic

¡High precision measurement of active and reactive energy

¡Connection method of current transformer with current measurement

¡Wide temperature typeLCDDisplay, instrument parameters can be remotely set through the display panel or computer

¡Programmable current and voltage conversion ratio

¡supportRS-485Communication,Modbus-RTUagreement

¡Support meritorious service/Reactive power pulse output

¡Easy installation, simple wiring, and small engineering quantity

¡Wide range AC/DC universal power supply:AC/DC80V270V

Product standards

¡GB/T 17215.321-2008 AC measuring equipment special requirements auxiliary word for ordinal numbers21Part: Static active energy meter(1Level and2level)

¡GB/T17215.322-2008Special Requirements for AC Measurement Equipment22Part: Static active energy meter(0.2SLevel and0.5Slevel)

¡GB/T 17215.323-2008 AC measuring equipment special requirements auxiliary word for ordinal numbers23Part: Static typenot haveElectric energy meter(2Level and3level)

Type Designation

图片1.png

TECHNICAL INDEX

measurement accuracy

active electrical energy

0.5SGrade or1level

reactive energy

2level

electric current

0.5level

INPUT

rated voltage

AC 220VAC 3×57.7/100VAC 3×100VAC 3×220/380V

Rated current

1.5(6)A

Overload

Voltage:1.2timessustain2times/1secondinstantaneous

electric current:1.2timessustain10times/5secondinstantaneous

power consumption

Voltage:0.5VAeach other

electric current:0.4VAeach other

frequency

4565Hz

Auxiliary power supply

scope of work

AC/DC80V270V

power consumption

4VA

functional module

communication interface

support1roadRS-485Communication,Modbus-RTUagreement

Baud rate:240019200bps, default9600bps

Electric pulse output

support2Pulse output of road electrical energy

environment

operation temperature

-20+60

storage temperature

-40+70

relative humidity

95%In non corrosive gas environments

altitude

2500m

External dimensions

Frame size(mm

96×48;96×96

Hole size(mm

944; 91×91

Function selection

Model Function

Number of phases

electric current

meritorious

metering

Reactive power

metering

pulse

output

communication

interface

holesize

mm

JD-101

single phase

1

1

91×44

JD-301

three-phase

1

1

91×91

JD-302

three-phase

1

1

JD-303

three-phase

2

1

Specification List

specifications

Pulse constant

Connection

voltage

electric current

220V

1.5(6)A

12000imp/kWh

Single phase (connected through current transformer)

3×57.7/100V

1.5(6)A

20000imp/kWh

Three phase four wire (connected through current and voltage transformers)

3×100V

1.5(6)A

20000imp/kWh

Three phase three wire (connected through current and voltage transformers)

3×220/380V

1.5(6)A

6400imp/kWh

Three phase four wire (connected through current transformer)