| SI biological oxygen consumption respiration meter Model: 53002-03 |
||||||||||||
![]() |
||||||||||||
| characteristic: SIBiological oxygen consumption respiration meter Can communicate with computers to accurately record biological oxygen consumption and respiratory movement measurements. Accurately measure the respiratory rate of mitochondria, suspended cells, and oxidases The complete system includes: dissolved oxygen meter, micro cathode electrode, and breathing chamber
1.Dissolved oxygen analyzer The dissolved oxygen meter can measure and monitor dissolved oxygen and respiration rate. The large-sized LCD can display dissolved oxygen values, oxygen partial pressure PO2 (torr, mmHg, kPa), or concentration (mg/L, ppm, µ g/L, µ mol/L,% saturation, etc.). The dissolved oxygen meter can interact with respiratory measurement software for dissolved oxygen monitoring, closed cell or flow-through cell respiratory measurement. The measurement results can be transmitted to the computer through a USB interface. The dissolved oxygen meter can be fully controlled on the computer screen through software. Control includes inputting all experimental parameters and calibration in the set mode, and recording the actual oxygen consumption trace in the recording mode; In analysis mode, the stored data can be called to automatically calculate the respiratory rate Dual channel dissolved oxygen analyzer: can be used as an independent dissolved oxygen analyzer or as an interface for computer interaction, and can be connected to two at the same time Electrode with respiratory measurement software Six channel dissolved oxygen meter: only used as an interface for computer interaction, can simultaneously connect six electrodes, with respiratory measurement software
Ordering Guide: 53002-03Dual channel dissolved oxygen analyzer 53002-21Six channel dissolved oxygen analyzer
2Micro cathode dissolved oxygen electrode
Clark type micro cathode dissolved oxygen electrode with PP film, jacket filled with buffered potassium chloride electrolyte, can be used for non stirred solutions. The response time of the electrode membrane is 18 seconds to reach 90% change. If a faster response time is required (9 seconds to reach 90% change), FEP membrane 53002-55 and electrode jacket 53002-58 can be used.
Ordering Guide: 53002-50Micro cathode oxygen electrode
3.Breathing pool
The respiratory metering tank is equipped with a glass water jacket connected to an external pump system for temperature control circulation
Mitochondrial pool:Miniature mitochondrial pools are used for mitochondria or small volume cell suspensions, with sample sizes of 0.3, 0.5, or 1.0 ml Comes with a fixed speed magnetic stirrer and stirring rod Breathing pool:Having different capacities. The glass breathing chamber is equipped with an acetaldehyde electrode sleeve with capillary sample injection holes, which can be used for subcutaneous injection Inject the sample with a syringe needle (including). The breathing chamber can be placed on a magnetic stirrer (purchased separately) and comes with its own breathing chamber PTFE coated stirring rod. Flowing pool:Used for monitoring or connecting flow-through breathing chambers. The flow-through pool is equipped with an acetaldehyde electrode sleeve and acrylic grease with inlet and outlet The cavity. The acrylic ester chamber must be immersed in a constant temperature water bath (purchased separately) Ordering Guide:
|