Rosemount metric or DIN RTD sensors (65, 65Q)
The Rosemount metric RTD exhibits very high linearity and a stable relationship between resistance and temperature. These sensors are mainly used in i
Product details
The Rosemount metric RTD exhibits very high linearity and a stable relationship between resistance and temperature. These sensors are mainly used in industrial environments that require high precision, durability, and long-term stability.
The 65 series is equipped with a range of intelligent temperature transmitters, which can improve performance and achieve optimal temperature measurement accuracy through calibration tables and Callendar van Dusen constants.
The 65Q model also includes hygiene products, which can provide hygiene process connections, polished stainless steel connectors, and shorter response times. Each metric RTD is part of our global network, ensuring consistent provision of high-quality products worldwide.
Fully encapsulated and sealed wiring connections
- High performance sensor element technology for accurate anti vibration operation
- Provide Callendar Van Dusen calibration to achieve the highest accuracy when paired with transmitters
- Certified global calibration facilities that comply with international standards
- Provide manufacturing capabilities for your largest and most complex projects
- The full range of products includes RTDs, thermowells, extensions, and transmitters
- Calculation of wake frequency
​​​​​​​​​​
temperature range -50 ° C to 450 ° C or -196 ° C to 600 ° C, depending on the model
self-heating 0.15 K/mW, Measure according to the method defined in DIN EN 60751:1996
thermal response time When tested in flowing water according to IEC 751, it takes up to 9 seconds to achieve 50% sensor response
Immersion error When tested according to IEC 751, the minimum usable immersion depth is 60 mm
insulation resistance The minimum insulation resistance tested at 500 Vdc at room temperature is 1000 M Ω
armoring material 316 stainless steel/321 stainless steel, with mineral insulated cable construction
wire PTFE insulation layer with silver plated copper wire.