English

Vikteri (Beijing) Technology Co., Ltd
Home>Products>RoHs/Halogen (Zero Halogen) Detection System x-5600
RoHs/Halogen (Zero Halogen) Detection System x-5600
RoHs/Halogen (Zero Halogen) Detection System x-5600
Product details
RoHs/halogen (halogen-free) detection system
Model X-5600
Product Overview:

The X-5600 RoHS tester is an energy dispersive X-ray fluorescence spectrometer that reflects the latest developments in X-ray fluorescence analysis technology. It uses a low-power water-cooled small X-ray tube as the excitation source,
The electrically cooled silicon semiconductor detector serves as the detection unit, coupled with our company's specially developed application software for unique analysis methods, fully leveraging the excellent performance of each component to ensure the integrity of the entire instrument
High resolution and universal adaptability. Wherever multiple elements need to be analyzed simultaneously, it is precisely where its potential lies.
Mainly used for detecting harmful elements in materials in industries such as electronics, hardware, packaging, toys, etc PVC、 Halogen (i.e. halogen-free testing) and RoHS testing in industries such as ceramics; Can also be used for
Plating analysis in the electroplating industry, glass, leather and other industries, as well as quality inspection and commercial inspection agencies.

Product features:
1Non destructive testingNo need for sample preparation, non-destructive and rapid analysis
2Dual box structure of the instrumentEffectively shielding interference, increasing the overall stability of the instrument, and ensuring the accuracy of measurement results
3.Triple radiation protection system:The sample chamber is opened, and the X-ray tube shutter automatically locks; When replacing the sample, the X-ray tube automatically cuts off the voltage and current; Multi layer shielding compartment cover of the instrument effectively prevents X-ray leakage
4.Silver copper dual peak self adjustment system:The dual peak positions of silver and copper are automatically calibrated simultaneously. When the peak position of the instrument deviates, the working curve can be corrected at any time. The software can automatically adjust and restore the instrument to normal measurement
State, avoid errors caused by system deviations, and ensure accurate measurement data at all times (the only software dual peak fully automatic adjustment system in the industry);
5.Temperature control system:Internally, a triple cooling system consisting of air cooling, water cooling, and oil cooling is used to minimize the operating temperature of the X-ray tube, effectively extend its service life, and ensure long-term stable operation of the instrument,
More accurate measurement accuracy;
6.Operating software:Open operating software allows users to conduct secondary development according to their own needs, achieving the maximum utility of the instrument and making it multifunctional;
7.Report format:The output report format can be independently designed according to user requirements, and users can also develop it themselves
8.quantitative analysis methodBasic parameter method, theoretical alpha coefficient method, empirical coefficient method, multiple regression method, etc. (the only comprehensive calculation method adopted in the same industry in China);
9.Qualitative analysis method:Automatic peak finding of elements, Kl spectral line labeling method, peak comparison method, etc
10. The calculation methods for analyzing strength include gross strength, net strength, spectral analysis, peak to back ratio, and internal standard ratio. The most appropriate strength calculation method can be selected according to different conditions.
11.Coating detection function:Multi layer detection of different metal coatings on different substrates
12.Optional:Optional mobile platform for easy object movement and multi-point detection

Technical parameters:
1Scope of elemental analysis:From aluminum (element 13) to uranium (element 92);
2Scope of Content Analysis:1mg/Kg - 10^6mg/Kg(1ppm=1 mg/Kg)
3Diverse types of measurement samplesSolid, powder, liquid;
4TimeQuick detection mode takes 2 seconds, normal detection mode takes 30-180 seconds, and can be freely selected by the user
5Analysis detection limit
The detection limit of chromium Cr is 2.1ppm;
The detection limit for mercury Hg is 3.2ppm;
The detection limit for lead Pb is 1.2ppm;
The detection limit of bromoBr is 0.3ppm;
The detection limit for cadmium Cd is 5.8ppm
The detection limit of chloroCl is 12.6ppm
According to Samsung's internal standards, antimony and Sb elements were tested with a detection limit of 4.3ppm
6excitation sourceUsing low-energy high-power X-ray tubes, with a maximum voltage of 50kV and a maximum current of 1mA;
7Filtering system+collimator10 types of filters and 5 types of collimators are automatically switched and combined to improve detection range and accuracy, and targeted detection conditions are adopted for different elements
8high voltageMaximum 50W, 50KV, 1mA;
9detectorAmptek imported X-123 SIPIN semiconductor detector with electric refrigeration from the United States;
10.Detection area: 6mm2
11resolution: The energy of 55Fe is 5.9Kev for MnK α lines, with a resolution better than 129eV; For a formation time of 12us, the full width at half maximum is 129eV
12.Thickness of silicon activation zone: 500μm
13.Detector windowBeryllium window, 12.5 μ m thick
14.Repeated measurement stabilityThe standard deviation of 10 consecutive measurements is less than 0.05%
15multi-channel analyzer2048 tracks;
16Camera: CCD optical lens;
17Sample imaging positioning systemBuilt in self sensing 5-megapixel camera and positioning software, convenient for local positioning and measurement of samples;
18Working power supplyAC 220V/50Hz
19Sample compartment size: 345×335×120(mm)
20External dimensions: 600×520×370(mm)
21Instrument weightApproximately 39 kilograms
22Working environment temperature:18℃—28℃
23Relative humidity of working environment:≤ 70%

Explanation of Safety Comparison Data:
Compare data:
Table 1. Comparison of European Standard EC681K Test Data: (Unit:) mg/Kg)
element Cadmium (Cd) Pb (lead) Mercury (Hg) Total chromium (Cr) Total Bromine (Br) Unit: mg/Kg (1ppm=1mg/Kg)
European standard EC681K 137 98 23.7 100 770
Bozhi X-5600 135.6 101.71 21.36 103.8 775.6
Error value with European standards -1.4 3.71 -2.34 3.8 5.6
Imported company instruments 146.45 121.45 31.95 75.25 882.35
Error value with European standards 9.45 23.45 8.25 -24.75 112.35


Table 2. Measurement results of EU standard samples EC681K and EC680K: (Unit:) mg/Kg)
element Cadmium (Cd) Pb (lead) Mercury (Hg) Total chromium (Cr) Total Bromine (Br) Company: mg/Kg(1ppm=1mg/Kg)
EC681K (First Time) 138.66 109.04 26.64 102.08 777.33
EC681K (second time) 138.45 108.74 25.33 109.75 775.72
EC681K (third time) 136.46 108.91 27.53 104 775.64
EC681K standard data 137 98 23.7 100 770
EC680k (first time) 18.06 13.57 7.55 18.61 101.51
EC680k (second time) 17.13 12.45 6.34 20.57 103.15
EC680k (third time) 18.56 15.97 6.69 17.67 105.75
EC680k standard data 19.6 13.6 4.64 20.2 96


Radiation Safety Report
Measurement point Measurement of Air Release Energy Rate (μ Sv/h)
5cm front surface of the instrument Less than 0.6
5cm on the back surface of the instrument Less than 0.6
5cm on the left surface of the instrument Less than 0.6
5cm on the right surface of the instrument Less than 0.6
5cm on the surface of the instrument Less than 0.6
5cm lower surface of the instrument Less than 0.6
operation bit Less than 0.6

According to the Health Protection Standard for X-ray Diffraction and Fluorescence Analyzer GBZ115-2002, an air specific energy release rate below 2.5 μ Sv/h is not harmful to the human body.