Shanghai Huile Electric Co., Ltd
Home>Products>Programmable intelligent digital display combination meter
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    1881753568318321031365
  • Address
    No. 95 Shihuxin Road, Shihudang Town, Songjiang District, Shanghai
Contact Now
Programmable intelligent digital display combination meter
Programmable intelligent digital display combination meter
Product details
  • Programmable intelligent digital display combination meter



Detailed Introduction

overview
The programmable digital voltmeter has the following functions and features:
The full-scale display value, upper and lower limit alarm values, and communication address can be freely set through the buttons on the panel, making it very flexible and convenient to use.
● Optional analog transmission output, 4-20mA, 0-20mA, 4-12-20mA, 0-5V, 1-5V optional.
● Optional 2-channel alarm output for monitoring the upper and lower limits of the measured parameters.
Optional RS485 digital interface, using standard MODBUS-RTU protocol.
Adopting direct communication RMS effective value measurement, digital zero calibration, digital tuning, high accuracy, and extremely high cost-effectiveness.
TECHNICAL INDEX
transport
enter
measure
measure
apparent
show
electricity
press
RATING AC100V, 400V (please specify when ordering)
overload Duration: 1.2 times Instantaneous: 2 times/10 seconds
power consumption < 1VA (per phase)
accuracy RMS measurement, accuracy level 0.5
electricity
flow
RATING AC 1A, 5A (please specify when ordering)
overload Duration: 1.2 times Instantaneous: 10 times/10 seconds
power consumption < 1VA (per phase)
accuracy RMS measurement, accuracy level 0.5
Power factor Active power accuracy level 0.5, reactive power accuracy level 1.0
power supply scope of work AC 220V ± 20% Special requirements can be customized
power consumption <5VA
output Digital Interface RS-485, MODBUS-RTU protocol (optional)
Switching Output Switch output, relay passive contact mode (optional)
analog output Analog transmission output, 4-20mA/0-20mA/4-12-20mA/0-5V/1-5V (optional)
environment work environment -10-55 ℃, relative humidity<85%. Non corrosive gas environment, altitude<2000m
Environment -55-85 ℃, relative humidity<85%
secure pressure resistance Power supply/output>1KV
isolation Input, output, and power supply to the chassis>100M Ω


List of Series Models and Sizes for Voltage, Current, and Frequency Combination Tables
model measure display Appearance and installation dimensions Peripheral functions (optional, to be specified when ordering)
A B C D E digital communication Switch Module Transmission output
HL-42KUIHz Voltage, current, frequency

LED

120 120 83 112 112 RS-485 4DI/4DO 4-channel transmission
HL-96KUIHz Voltage, current, frequency LED 98 98 83 90 90 RS-485 4DI/4DO 4-channel transmission
HL-80KUIHz Voltage, current, frequency

LED

84 84 83 76 76 RS-485 2DO 4-channel transmission
HL-72KUIHz Voltage, current, frequency

LED

75 75 90 67 67 RS-485 2DO 4-channel transmission
HL-45KUIHz Voltage, current, frequency LED 50 50 83 45 45 RS-485 or 2-channel transmission 2DO RS-485 or 2-channel transmission
HL-48KUIHz Voltage, current, frequency LED 51 99 83 45 45 RS-485 or 2-channel transmission 2DO RS-485 or 2-channel transmission


List of Series Models and Sizes of Single phase Voltage and Current Combination Meters
model measure display Appearance and installation dimensions Peripheral functions (optional, to be specified when ordering)
A B C D E digital communication Switch Module Transmission output
HL-42KUI Voltage and current

LED

120 120 83 112 112 RS-485 4DI/4DO 4-channel transmission
HL-96KUI Voltage and current LED 98 98 83 90 90 RS-485 4DI/4DO 4-channel transmission
HL-80KUI Voltage and current

LED

84 84 83 76 76 RS-485 2DO 4-channel transmission
HL-72KUI Voltage and current

LED

75 75 90 67 67 RS-485 2DO 4-channel transmission
HL-45KUI Voltage and current LED 50 50 83 45 45 RS-485 or 2-channel transmission 2DO RS-485 or 2-channel transmission
HL-48KUI Voltage and current LED 51 99 83 91 45 RS-485 or 2-channel transmission 2DO RS-485 or 2-channel transmission


List of Series Models and Sizes of Single phase Voltage Current Active Power Combination Tables
model measure display Appearance and installation dimensions Peripheral functions (optional, to be specified when ordering)
A B C D E digital communication Switch Module Transmission output
HL-42KUIP Voltage, current, active power

LED

120 120 83 112 112 RS-485 4DI/4DO 4-channel transmission
HL-96KUIP Voltage, current, active power LED 98 98 83 90 90 RS-485 4DI/4DO 4-channel transmission
HL-80KUIP Voltage, current, active power

LED

84 84 83 76 76 RS-485 2DO 4-channel transmission
HL-72KUIP Voltage, current, active power

LED

75 75 90 67 67 RS-485 2DO 4-channel transmission
HL-45KUIP Voltage, current, active power LED 50 50 83 45 45 RS-485 or 2-channel transmission 2DO RS-485 or 2-channel transmission
HL-48KUIP Voltage, current, active power

LED

51 99 83 91 45 RS-485 or 2-channel transmission 2DO RS-485 or 2-channel transmission


List of Series Models and Sizes of Single phase Voltage Current Power Factor Combination Tables
model measure display Appearance and installation dimensions Peripheral functions (optional, to be specified when ordering)
A B C D E digital communication Switch Module Transmission output
HL-42KUIPF Voltage, current, power factor

LED

120 120 83 112 112 RS-485 4DI/4DO 4-channel transmission
HL-96KUIPF Voltage, current, power factor LED 98 98 83 90 90 RS-485 4DI/4DO 4-channel transmission
HL-80KUIPF Voltage, current, power factor

LED

84 84 83 76 76 RS-485 2DO 4-channel transmission
HL-72KUIPF Voltage, current, power factor

LED

75 75 90 67 67 RS-485 2DO 4-channel transmission
HL-45KUIPF Voltage, current, power factor LED 50 50 83 45 45 RS-485 or 2-channel transmission 2DO RS-485 or 2-channel transmission
HL-48KUIPF Voltage, current, power factor

LED

51 99 83 91 45 RS-485 or 2-channel transmission 2DO RS-485 or 2-channel transmission

Wiring example diagram

Order List
When placing an order, please specify in detail the required model, input signal ratio, and expansion function module.
Example 1: Model: HL-96KUIHz Power Supply: AC220V Input: 10KV/100V 200A/5A
Communication: RS485/MODBUA-RTU Function Expansion: 4DI/4DO Quantity: 88 units


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!