Price of laboratory ultrapure water purifierintroduce
In the field of scientific research and detection analysis technology, the purity of water has a significant impact on its results, especially when it comes to trace and trace analysis. It is necessary to avoid serious interference between ions and have stricter requirements for water purity. Therefore, in order to meet the water requirements of different technologies and effectively remove impurities such as electrolytes, organic matter, microorganisms, and various gases from tap water, it is necessary to prepare high-quality pure water and ultrapure water.
Beijing Ying'an Meicheng Scientific Instrument Co., Ltd1998Dedicated to the development, research, and production of ultrapure water purifiersMWThe series of laboratory grade pure water purifiers adopt advanced reverse osmosis technology and comprehensively utilize various water treatment technologies to directly treat urban tap water. They use dual flow channels to obtain both pure water and ultrapure water. Yield10—50rise/Hour by hour, the prepared ultrapure water meets the requirements of China's national laboratory waterGB6682Standard.
Price of laboratory ultrapure water purifier application area
This instrument is suitable for atomic absorption spectroscopy, atomic emission spectroscopy, high-performance liquid chromatography, ion chromatography, mass spectrometry analysisICPThe application of trace analysis and dilution analysis reagents such as plasma emission spectroscopy in general chemical laboratories is also suitable for pure water and ultrapure water used in industries such as precision optical lenses and photosensitive film processing.
characteristic
★ Zui has always used a stainless steel spray coated shell, which is compact and beautiful, does not take up a lot of space, and can be moved freely according to different water usage points, making it convenient and flexible.
★ The key components are made of high-quality imported accessories to ensure high-quality water output.
★ Sealed design to avoid secondary pollution.
★ Real time monitoring of water quality,Alarm for conductivity and resistivity set values; Automatic conversion between pure water and high-purity water; Dual output, capable of simultaneously producing pure water and ultrapure water.
★ Low noise, low energy consumption, energy-saving compared to traditional distilled water machines90%Above, reduce operating costs.
★ Extremely easy to install and use, no special installation or pipeline connection required; Simply plug in the power socket, connect the water source, and press the button to produce ultrapure water.
Technical characteristics of laboratory ultrapure water purifier
★ The quality of raw water only needs to meet the urban tap water standards, and the conductivity should be less than550μs/cmIt can meet the requirements and is significantly higher than the applicable range of other instruments.
★ Equipped with a dual outlet system, achieving high water output and low outlet resistivity in one machineTOCMultiple functions, including indicators and low bacterial count indicators, meet the water requirements of different customers and levels.
The instrument adopts a precision six stage filtration system, effectively ensuring high-quality effluent water quality. After institutional testing, the effluent from each channel is higher than the laboratory water standard and meets the requirements of the United StatesASTM,NCCLS,CAPWait for pure water indicators, and the resistivity of high-purity water can be maintained for a long time18.25MΩ·cmAnd it has an upgrade function.
★ All components are made of high-quality accessories from Dow and Kevlar in the United States, which comply with American standardsNSFAccording to the standards of the Water Quality Association* The anti scaling design not only achieves high-quality water quality, but also greatly shortens the replacement time of consumables and minimizes maintenance costs in the later stage.
Equipped with a UV lamp system, it can strictly ensure the total number of bacteria andTOCIndicator, our company is based in the United StatesOIon line24Hour by hour testing, confirmedTOCThe indicators have been consistently stable5-10ppbfollowing.
The instrument is equipped with a real-time detection system, touch sensitive buttons, and a LCD screen display for easy observation, allowing for real-time monitoring of indicators such as effluent quality and water temperature.
Easy installation, simple control, and powerful functionality. It has functions such as automatic alarm, consumable replacement reminder, etc. When the raw water is short or the water tank is full, it can automatically stop running and achieve unmanned supervision.
Technical Parameter
model | MW-D10 | MW-D20 | MW-D30 | MW-D50 |
Water production rate | 10L/H | 20L/H | 30L/H | 50L/H |
Requirements for inlet water quality | Urban tap water TDS<360ppb Inlet pressure>0.2MPa | Urban tap water TDS<360ppb Inlet pressure>0.2MPa | Urban tap water TDS<360ppb Inlet pressure>0.2MPa | Urban tap water TDS<360ppb Inlet pressure>0.2MPa |
Produced water quality | Pure water 1-5 μ s/cm High purity water 10-18.25M Ω. cm @25℃ | Pure water 1-5 μ s/cm High purity water 10-18.25M Ω. cm @ 25℃ | Pure water 1-5 μ s/cm High purity water 10-18.25M Ω. cm @ 25 ℃ | Pure water 1-5 μ s/cm High purity water 10-18.25M Ω. cm @ 25 ℃ |
total organic carbon | ≤10ppb | ≤10ppb | ≤10ppb | ≤10ppb |
heat source | <0.001EU | <0.001EU | <0.001EU | <0.001EU |
particulate | ≤1/ml | ≤1/ml | ≤1/ml | ≤1/ml |
microorganism | ≤1cfu/ml | ≤1cfu/ml | ≤1cfu/ml | ≤1cfu/ml |
Resin cycle water production | 8 tons | 8 tons | 16 tons | 16 tons |
Pump noise | Adopting a new type of pressure pump, the noise level is less than 20 decibels | Adopting a new type of pressure pump, the noise level is less than 20 decibels | Adopting a new type of pressure pump, the noise level is less than 20 decibels | Adopting a new type of pressure pump, the noise level is less than 20 decibels |
Resistivity detector | 0.01 cm-1 stainless steel electrode Temperature sensitivity: ± 0.1 degrees | 0.01 cm-1 stainless steel electrode Temperature sensitivity: ± 0.1 degrees | 0.01 cm-1 stainless steel electrode Temperature sensitivity: ± 0.1 degrees | 0.01 cm-1 stainless steel electrode Temperature sensitivity: ± 0.1 degrees |
Terminal filtering (optional) | German Sartorius 0.22um terminal filter | German Sartorius 0.22um terminal filter | German Sartorius 0.22um terminal filter | German Sartorius 0.22um terminal filter |
Power requirements | AC 220V/50Hz 5A | AC 220V/50Hz 5A | AC 220V/50Hz 5A | AC 220V/50Hz 5A |
Equipment size W×D×H (mm) | 440×555×700 | 440×555×700 | 500×565×1040 | 560×680×1105 |