PLC control of hot deformation Vicat temperature measuring instrument
Product details

1、 Purpose and Function:

Suitable for the determination of thermal deformation and Vicat softening point temperature of various non-metallic materials. This model is controlled by Taiwan's Delta PLC (Programmable Logic Controller), with high temperature control accuracy, small temperature gradient, and functions such as temperature upper limit protection.

2、 Applicable standards:

GB/T1633、GB/T1634、GB/T8802、ISO75、IS0306

3、 Instrument features:

1. The sample holder is an integrated structure with a small coefficient of expansion, and the experimental data is true and accurate.

2Adopting Taiwan's Delta PLC modular independent control system, different product components can be interchanged for easy operation, stable performance, high precision, long service life, and low maintenance and repair costs.

3. The three station high-precision displacement sensor is integrated with the PLC electronic control system. Compared to low-end machines (measuring deformation with a dial gauge and controlled by a microcontroller), this machine does not require manual intervention during the testing process. After each station completes the test, the LCD screen records the deformation amount and temperature of the sample at that station. Other station tests are not affected until all tests are completed, and the system automatically stops heating up, indicating that the test has been completed and automatically storing the test results.

4. The heating medium box is made of 304 stainless steel, and the interlayer is filled with asbestos for insulation. Compared with ordinary galvanized plate medium box, it has the characteristics of aging resistance, corrosion resistance, and no peeling under high temperature.

4、 Main technical parameters:

1. Temperature control range: room temperature -300 ℃

2. Heating rate: 50 ℃/h with an error of ± 0.5 ℃/6min

120 ℃/h error ± 1.0 ℃/6min

3. Temperature resolution: 0.1 ℃

4. Deformation measurement method: displacement sensor

5. Deformation measurement range: 0-1mm (standard configuration)

0-3mm (non-standard configuration)

6. Deformation resolution: 0.001mm

7. Number of sample racks: Three

8. Sample span: 64-100mm

9. Heating medium: Methyl silicone oil

10. Power supply: AC220V ± 10%, 50Hz

11. Cooling method: circulating water cooling

12. Model: Floor standing

5、 Configuration List:

Serial Number

name

specifications

unit

quantity

notes

1

host


tower

1


2

sample holder


cover

3


3

weight

2000g

individual

3


1000g

individual

6


500g

individual

3


200g

individual

6


100g

individual

3


50g

individual

3


Basic weights

individual

3

Installed on the sample rack

4

Vicat test needle


individual

3


5

Pressure head for hot deformation test


individual

3


6

Displacement sensor


only

3


7

power line


root

1


8

operation instructions


share

1


9

packing list


share

1


10

certificate of conformity


share

1