PH/ION 7320 multi parameter water quality analyzer (capable of measuring ions)Product Introduction:
1. Dual channel input, capable of simultaneously testing pH/ORP and ion concentration;
2. Embedded CMC measurement range monitoring to improve the accuracy of test results;
3. Large size graphic display screen with rich content;
4. Optional 2-7-point linear measurement and multiple built-in measurement algorithms;
5. Comes with USB output interface and optional built-in printer;
6. Multiple concentration units to choose from;
7. PH calibration from 1 to 5 points;
8. ISE calibration from 2 to 7 o'clock, and various non-linear calibration methods can also be used;
9. Multiple ion concentration units are available for selection.
PH/ION 7320 multi parameter water quality analyzer (capable of measuring ions)Technical parameters:
model |
inoLab pH/ION 7320 |
Test range/Accuracy (±)1Position) |
-2.0-20.0±0.1pH -2.00-20.00±0.01pH -2.000-19.999±0.005pH ±1200.0mV±0.3mV ±2500 ±1mV 0.000-9.999 mg/lion concentration 10.00-99.99 mol/lion concentration 100.0-999.9 mg/kgion concentration 1000-999999 ppm%ion concentration |
temperature |
-5.0-+105℃ ±0.1℃ |
CMC |
have |
correct |
1to5droppH 2to7dropISE |
Correction record |
10group |
temperature correction |
automatic/hand movement |
display |
Black and white graphics and text |
memory |
hand movement200group/automatic5000group |
interface |
microUSBinterface |
power supply |
alkaline battery/universal power supply |
size |
190*240*80(High)*long*Wide) |
weight |
0.8kg/1.0kg(including printer) |
3、 Ion selective electrode
1、ISEelectrode800series
Detecting ions |
film |
Built in reference electrode |
Bridge electrolyte |
Ionic strength calibration solution |
Standard solution(conc.10g/l) |
pHrange |
bromine |
S |
Br 800 |
ELY/BR/503 |
ISA/FK |
ES/Br |
1-12 |
Calcium, magnesium③ |
L |
Ca 800① |
ELY/BR/503 |
ISA/Ca |
ES/Ca |
2.5-11 |
chlorine |
S |
Cl 800 |
ELY/BR/503 |
ISA/FK |
ES/Cl |
2-12 |
cyanogen |
S |
CN 800 |
ELY/BR/503 |
MZ/NH3/CN |
- |
0-14 |
Fluorine, aluminum, phosphorus ③, lithium ③ |
S |
F 800 |
ELY/BR/503 |
TISAB |
ES/F |
5-7 |
potassium |
L |
K 800① |
ELY/BR/503/K |
ISA/K |
ES/K |
2-12 |
copper |
S |
Cu 800 |
ELY/BR/503 |
ISA/FK |
ES/Cu |
2-6 |
nitrate |
L |
NO 800① |
ELY/BR/503/N |
TISAB/NO3 |
ES/NO3 |
2.5-11 |
silver |
S |
Ag/S 800 |
ELY/BR/503 |
ISA/FK |
- |
2-12 |
sulfur |
S |
Ag/S 800 |
ELY/BR/503 |
④ |
- |
2-12 |
2ISEelectrode500Series(500Electrode series except for the following2Outside of the species, possessing all800The half electrodes corresponding to the composite electrode series have the same parameters, exceptNH 500/2Each external device requires a separate reference electrode
Ammonia nitrogen |
- |
NH500/2 |
- |
MZ/NH3/CN |
ES/NH4 |
4-12 |
sodium |
G |
DX 223 NA |
- |
ISA/Na |
ES/Na |
>10 |
① Exchange measuring head ②S=Solid state electrodes,L=Matrix electrode,G=Glass electrode ③ Titration method ④ Use according to the operating instructions ⑤ Formula of other required reagents in the application program and operating instructions