TP-1M Coating Thickness GaugeIntroduction:
Portable coating thickness gauge NOVOTEST TP-1M - a device for non-destructive testing of coating thickness with high measurement accuracy.
TP-1M Coating Thickness GaugeDesigned for testing:
The thickness of various protective coatings on various metals and alloys;
• Thickness of paint and other dielectrics - frankincense on steel, PTFE, plastic, radio protection, electroplated coatings;
The thickness of electroplating and paint coatings on non ferromagnetic alloys and non-ferrous metals;
The thickness of asphalt and other coatings on various metals or alloys;
And relative humidity, air temperature, surface temperature, dew point temperature, and the difference between surface temperature and dew point temperature are used to estimate groove depth and surface roughness.
TP-1M Coating Thickness Gaugeadvantage:
• Wide thickness measurement range
• Easy to operate and convenient to operate
• Low level operation: keys correspond one-to-one with functions
• Backlit graphic display
• Automatic recognition probe
• Indicate the type of probe to be connected
• Battery
TP-1M Coating Thickness GaugeStandard includes:
One coating thickness gauge host
• Probe -1 piece
• A set of reference samples
AAA batteries -2 pieces
• Charger
• Operation manual
• Packaging box
TP-1M Coating Thickness GaugeOptional Options
• Additional probes (customizable upon request)
• Battery
• Customized reference samples
• Charger
TP-1M Coating Thickness GaugeTechnical parameters:
Measurement thickness range (depending on sensor model)
0 μm ... 60 mm
Overall size, millimeters
120х60х25
Working temperature range
-5°C ... +40 °C
battery
2 AAA
Continuous working hours, not less than
20
Total weight including battery
0.2 kilograms
Probe specifications for coating thickness gauge NOVOTEST TP-1M
Ukraine NOVOTEST coating thickness gauge Ukraine NOVOTEST coating thickness gauge Ukraine NOVOTEST coating thickness gauge Ukraine NOVOTEST coating thickness gauge Ukraine NOVOTEST coating thickness gauge
Dielectric and conductive coatings on ferromagnetic metals or alloys
Probe model
Coating thickness range
measurement accuracy
Probe size, millimeters
probe F-0,3
0-300 μm
± (3% ± 1 μm)
Ø5x40
probe F-0,5
0-500 μm
± (3% ± 1 μm)
Ø 7x14
probe F-2
0-2000 μm
± (3% ± 2 μm)
Ø 9x35
probe F-5
0-5000 μm
± (3% ± 2 μm)
Ø 18x35
Coatings on non-magnetic metals (dielectric coatings on non-ferrous metals and alloys)
probe NF-0,5
0-500 μm
± (3% ± 2 μm)
Ø 12x35
probe NF-2
0-2000 μm
± (3% ± 2 μm)
Ø 12x35
Thick coating on metal (dielectric coating on metal)
probe M-12
0-12 mm
± (3% + 0.002 mm)
Ø 15x50
probe M-30
1-30 mm
± (3% + 0.003 mm)
Ø 40x50
probe M-60
1-60 mm
± (3% + 0.005 mm)
Ø 70x60
Measure surface roughness, Rz (after sandblasting pre coating work)
probe DSH
2-360 μm
± (3% ± 2 μm)
Ø 12x45
Temperature, humidity, and dew point
probe DT
-50 . .. +125 °C
+ / - 1 °C
Ø 15x45
probe DTVR
Humidity: 0-*
Temperature: -50 .. 125 °C
Dew point: -15-+40 ° C
± 5%
± 1 °C
± 2 °C
Ø 15x120