Miccra online circulating (homogeneous) working chamber
Miccra (formerly ART) online circulation (homogenization) working chamber DFK, the circulation system makes rapid and efficient product development po
Product details

Miccra (formerly ART) online circulating (homogeneous) working chamber DFK

The circulatory system enables rapid and efficient product development. Similarly, modular rotors for all batch series/All stator components can be applied here.

This is the first time, it can be usedMICCRABatch structure of laboratory series.

Flexible use of quick clamps to connect various types of pipes, gaskets, containers (single-layer, double-layer, sealed, open), and valves to the system, and simulate production with small sample experiments.

Mechanical systems can also be utilized to obtain the precision of nanoscale samples. What has been accumulated is only applicable to future pilot or mass production.

This is a flexible solution provided for short-term continuous work. Our standard laboratory homogenizerMICCRA D-15orMICCRA D-9The host can achieve it.

This is a circulating chamber system suitable for continuous operation in laboratories or intermediate laboratories. givehostMICCRA D-27The connection, you will receiveNano level results.


“MICCRA DFK Lab'Easy and fast cleaning, it is an efficient circulation chamber system for laboratory processing of small samples.

Based on superior modular design, all batches and series of rotors/Stator components can be applied to circulatory systems. Due to the extraordinary high rotational speed, the precision of the sample can reach40nm(depending on the characteristics and application of the sample).

So far, no other system has achieved such an effect with such a small system.



DFK'The working chamber system can be processed online in the laboratory or laboratory experiments/Large capacity of circulation. The high-quality stainless steel solid components and wear-resistant sealing materials ensure its various applications in the industrial field.

n chemistry/Flow ability due to changes in physical properties

n Prescription creation

n Cost savings in handling small samples in the research field

Transitioning from laboratory to future mass production

Sealing type

You can choose a single mechanical seal andFDACertified lip seal.

The suspended box structure makes the lip seal easy to clean and convenient for users to replace. Repair work saves money and time.



Flexible combination of stators of different sizes/rotor

Innovative box seal structure allows for quick replacement of lip seals

Easy cleaning and maintenance

Highly polished blade components


Attachment: Stainless steel cups with different capacities(13perhaps5There are single-layer and double-layer structures available; Hose fittings, gaskets, and three-way valves, etc

Technical Parameter


DFK 1.0


Knife head kit

20mm

30mm

Circulation volume (water):

15ml/min

26ml/min

Maximum cutting speed:

30 m/s

41 m/s

Rotor diameter:

15mm

23mm

Stator diameter:

20mm

30mm

Moh hardness:

Maximum 6

Maximum 6

Maximum pressure:

8 Bar

8 Bar

Vacuum degree:

1 mbar

1 mbar

Sterilization and decontamination:

CIP

CIP



DFK 1.4


Knife head kit

20mm

30mm

40mm

Circulation volume (water):

10ml/min

26ml/min

45ml/min

Maximum cutting speed:

30 m/s

41 m/s

46 m/s

Rotor diameter:

15mm

23mm

36.3mm

Stator diameter:

20mm

30mm

40mm

Moh hardness:

Maximum 6

Maximum 6

Maximum 6

Maximum pressure:

16 Bar

16 Bar

16 Bar

Vacuum degree:

1 mbar

1 mbar

1 mbar

Sterilization and decontamination:

CIP

CIP

CIP


Product optimization

DFK 1.4 is a solution for developing a small-scale cyclic system. The host based on MICCRA D-27 has a power of 2.7W and a speed of 36000 revolutions per minute, which can more efficiently obtain higher quality samples.

The experimental results can be obtained repeatedly at any time and can be extended to larger processing capacities in the future

The refinement of mixing and samples is obtained by optimizing the combination of different rotors/stators.

Due to the bearingless rotating shaft between the circulation chamber and the motor drive, the system is very smooth and particularly easy to clean and maintain.

The ideal solution for short-term continuous work

The DFK 1.0 cycle system enables rapid and efficient product development. Similarly, modular rotor/stator components from all batch series can be applied here.

This is the first time that the batch structure of the MICCRA laboratory series can be used

Flexible use of quick clamps to connect various types of pipes, gaskets, containers (single-layer, double-layer, sealed, open type), valves to the system, and simulate production with small sample experiments.

Mechanical systems can also be utilized to obtain the precision of nanoscale samples. The accumulated knowledge can be applied to future pilot or mass production


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!