Magnetic sensitive electric contact pressure gauge YXH-100/YXH-150
Anti vibration magnetic sensitive electric contact pressure gauge YXH-100-Z YXH-150-Z
Stainless steel anti vibration magnetic sensitive electric contact pressure gauge YXH-100B-Z/YXH-150B-Z
Magnetic sensitive electric contact pressure gauge has characteristics of resistance to environmental vibration, medium pulsation, and impact load. The instrument indication is clear and stable, and the electrical signal switching is reliable.
Magnetic sensitive electric contact pressure gauge is suitable for pressure measurement of liquids, gases and other media that have no corrosive effect on copper or copper alloys. In addition to its indication function, it also has a two position adjustable signal control with upper and lower limits.
The liquid material of the stainless steel magnetic sensitive electric contact pressure gauge is stainless steel 316SS, which can be used to measure corrosive media. Simultaneously equipped with two adjustable signal controls for upper and lower limits.
The magnetic sensitive electric contact pressure gauge has extremely high sensitivity, fast response, and no hysteresis or jumping phenomenon. When working at low voltage, the contact type device is generally immersed in damping fluid, and its contacts attach an oil film,
The increase in contact resistance makes the contacts ineffective. The YXH instrument's contacts are vacuum sealed, ensuring reliable signal switching, no arcing, long service life, and excellent switching characteristics.
Magnetic sensitive electric contact pressure gauge is suitable for low voltage and low current operation, especially for computer users with 24V DC voltage for control signal switching.
Technical parameters:
measuring range MPa |
0~0.1;0~0.16;0~0.25;0~0.4;0~0.6;0~1;0~2.5;0~4.0;0~6.0;0~10; 0~16;0~25;0~40;0~60;0~100;0~160;0-250;-0.1~0;-0.1~0.15;-0.1~0.3; -0.1~0.5;-0.1~0.9;-0.1~1.5;-0.1~2.4; |
accuracy |
±1.6% |
Using working temperature |
-10℃~55℃ |
Use pressure upper limit |
2/3 |
Anti working environment vibration |
V.H.4level |
Protection level |
IP64 |
Large working voltage |
DC 24V |
Large switch current |
0.1A |
High power (no inductive load) |
1W |
Instrument execution standard: JB/T9273-1999;
Wiring diagram:
External dimensions:
model |
External dimensionsmm |
|||||||
D1 |
D2 |
L2 |
L1 |
H |
d |
d0 |
M |
|
YXH-100ZQ-Z |
100 |
98 |
23 |
78 |
38 |
118 |
5.5 |
20×1.5 |
YXH-100Z-Z |
100 |
98 |
28.5 |
78 |
38 |
/ |
/ |
20×1.5 |
YXH-100-Z |
100 |
98 |
28.5 |
78 |
38 |
/ |
/ |
20×1.5 |
YXH-150-Z |
150 |
161 |
35 |
90 |
42 |
/ |
/ |
20×1.5 |
Usage and ordering instructions:
The working environment should be free of corrosive gases.
After installation, please cut off the protruding rubber plug on the top of the instrument case to allow the instrument cavity to communicate with the atmosphere, in order to ensure the accuracy of the instrument.
Please specify the name, model, and measurement range when placing an order.
Please specify the corrosive environment or corrosive medium separately.