Features |
- Applicable standards include GB31485-2015, UN38.3, IEC62133-2012, GB31467.3-2015, etc;
- Adopting customized arc extinguishing short-circuit switches to ensure the safety and reliability of short-circuit circuits;
- Customized resistor cabinet to meet the matching needs of different resistors;
- PC based short-circuit control system, convenient for operation and collection of test data, capable of video surveillance;
- Design multi-channel wiring blocks for different sizes of short-circuit currents and resistors;
- Simultaneously design a battery surface temperature measurement device, which can record the testing current and voltage;
- Select high-quality electrical components with the ability to switch between local and remote operations;
Technical Specifications | |
power supply |
Voltage three-phase 380VAC ± 10%, frequency 50Hz, power 8KW |
Usage environment |
Suggested ambient temperature 25 ± 3 ℃, humidity 30~90RH (%), no vibration and electromagnetic interference |
test project |
Short circuit testing of lithium-ion batteries, battery modules, and external packaging |
Applicable standard |
GB31485-2015、 UN38.3, IEC62133-2012, GB31467.3-2015, etc |
short-circuit voltage |
Max.600V, 精度 ±0.1%,4 通道 |
short-circuit current |
Max. 12000A, 精度 ±0.2%,1 通道 |
Battery temperature measurement |
Max. 200℃, accuracy ± 1 ℃, 4 channels |
Short circuit resistance |
Three options are available: 2-4 m Ω, 15-20 m Ω, and 80 ± 20m Ω |
Console installation dimensions |
W1600mm*D700mm*H1100mm |
Installation dimensions of short-circuit machine |
W800mm*D700mm*H1000mm |
Installation dimensions of resistance cabinet |
W1600mm*D700mm*H2000mm |