The HL1803 tire airtightness testing system consists of several parts, including the HL1001T measurement and control system software platform, HL1802 data communication protocol, various testing sensors (pressure, temperature, atmosphere), and testing bench.
The design goal of this system is to enable testing engineers to easily collect, record, display, analyze, and output tire pressure on site. Simultaneously complete the synchronous collection of on-site testing environment parameters.
In addition, the system can also communicate with the calibration system, allowing engineers to quickly and conveniently detect and calibrate multiple pressure sensors.
1. Data collection function
This acquisition system can simultaneously collect 40 signals, and engineers can manually start or stop it
data acquisition,Users can freely choose the number of channels to be collected, the collection frequency, and the type of signal to be collected for each channel
Type.
2. Real time curve display
Engineers can choose to display curves of multi-channel signals simultaneously, or select multiple of them simultaneously
A line or a curve.
Engineers can choose to zoom in or out of the timeline, so that they can clearly see the long-term changes in the signal
Or short-term changes.
At the same time, engineers can also choose the starting and ending points of the collection time to review the previous data
Let it go.
3. Data storage
The data will be automatically stored in the computer's hard drive, and engineers can collect the pressure, temperature, and atmosphere
Export data to an EXCEL file.
The size of stored data depends on the size of the hard disk space.
4. Verification function (optional function)
After connecting the standard pressure sensor, the calibration system can be entered to test the sensors in the system
Perform verification. The system generally defaults to 5 points for verification (0 20%, 40%, 60%, 80%, 100%),
The system can automatically match the difference between the standard sensor and the verified sensor, and correct the verified sensor
The error of the device.
Serial number, name, technical indicators
1. Collection system name HL1803
2 Test Bench
1. Power supply voltage: 220V AC;
2. Installation dimensions (height x length x width)=120x90x100 (cm);
3. Equipped with universal wheels for easy mobility;
3 Computer Configuration
WIN7 system
I3 independent graphics card
19 inch display screen
500G hard drive
4 Collection System
1. Collection frequency: 1 second 10 seconds 60 seconds 10 minutes 15 minutes 30 minutes 1 hour can be set;
2. Collection channel: 40 channels (including 32 pressure channels, 1 atmosphere channel, 1 temperature channel, and 1 standard channel)
Pressure input, 7 backup channels) (Channels can be customized according to customer requirements, including 8 channels, 12 channels, 16 channels, 32 channels, 40 channels, 60 channels, etc.)
3. Each channel input signal type is optional (0-1.6MPa/0-0.8MPa/0-0.4MPa/Temperature/Large)Air pressure);
4. Nonlinear calibration function of pressure sensor.
HL1001T measurement and control system software platform, HL1802 data communication protocol, various testing sensors (pressure, temperature, atmosphere), testing bench