Low nitrogen FGR gas hot water boiler - integrated condensing type
The independent FGR technology has tested that NOX meets the emission standards of first tier cities. Multiple heating units in Beijing have selected
Product details

3.jpg



Autonomous FGR technology truly low nitrogen products

4.jpg

Beautiful appearance and long-lasting lifespan

The Fangkuai FGR boiler perfectly combines flue gas recirculation technology with various furnace types to create truly low nitrogen products, with measured NOX<27mg/m3.

Surface spray coating treatment, beautiful and novel; No scaling, long lifespan

5.jpg Quick and easy installation, simple maintenance in the later stage

6.jpg

Fully intelligent Chinese operation is simple and intuitive

Quick loading furnace body design, no special requirements for the siteDon't demand, AnQuick and easy installation;

Real time dynamic display, real-time performance calculation, touch screen interface, multi-layer password setting, intuitive and fast operation.

Performance advantages

Truly low nitrogen and environmentally friendly products that meet the emission standards of first tier cities, mainly selected for coal to gas conversion in multiple regions


方快低氮FGR燃气热水锅炉


Fangkuai FGR TechnologyIt is a technology that uses the flue gas at the outlet of the boiler to enter the boiler again as inlet air through equipment, reducing the flame temperature and thus suppressing the production of NOx. In order to perfectly apply this technology to gas boilers, the technical R&D personnel of Fangkuai Boiler conducted multiple experiments and records on the boiler structure and design, and finally optimized it continuously to control NOX emissions within the standard range.


方快低氮FGR燃气锅炉结构


Original FGR technology tested NOX<27mg/m3


  • Independent innovation of FGR technology for low nitrogen, energy saving and environmental protection

  • Adopting new combustion technology to configure the condenser

  • Improve thermal energy utilization efficiency by over 8%

  • Save nearly 10% of natural gas fuel


方快FGR燃气锅炉结构特点



Special structural design significantly improves product performance


  • Adopting a conical furnace structure (partially) to avoid the accumulation of high-temperature flue gas and ensure low nitrogen emissions;

  • The diameter of the large furnace chamber ensures sufficient space for flue gas recirculation and recirculation;

  • Large water volume design, the boiler is not sensitive to load fluctuations;

方快承压热水锅炉控制面板



The operation interface is intuitive and simple, and the running status is clear at a glance


  • Adopting high-resolution color touch screen

  • Real time dynamic display of the operating status and flame changes of burners, circulation pumps, etc., at a glance.

  • A multi-level pop-up menu in Chinese simplifies, organizes, and intelligentizes boiler monitoring

  • Chinese troubleshooting guide, easy to operate


方快燃气热水锅炉防护装置


Multiple intelligent warning functions ensure safe and efficient operation


  • Multiple safety protections such as electric contact pressure gauges and safety valves;

  • Equipped with high pressure protection: When the pressure inside the boiler exceeds the maximum pressure set by the user, the overpressure indicator light will turn on, the inspection light will flash, an alarm will sound, and the burner will be prohibited from working (to prevent further pressure increase).

  • Equipped with scale alarm function: Real time monitoring of the formation of scale on the heating surface, and automatic alarm prompt once exceeding the standard.

  • It has the ability to promptly prohibit the operation of the burner and sound an alarm in case of power outage, undervoltage, overcurrent, short circuit, phase loss, over burning prevention, and other sudden faults.

  • Equipped with over temperature protection function: When the boiler outlet water temperature is higher than the set value, the controller (electric contact bimetallic thermometer sends a command) prohibits the burner from working and emits an alarm sound.




For detailed information about Fangkuai Boiler products, please call our customer service hotline or click on the online consultation button on the right

Customer service hotline: 400-100-9030


Technical Parameter

Parameters of integrated condensing low nitrogen pressure hot water boiler

Project model WNS0.7-1.0/95/70-Y.Q WNS1.4-1.0/95/70-Y.Q WNS2.1-1.0/95/70-Y.Q WNS2.8-1.0/95/70-Y.Q WNS4.2-1.0/115/70-Y.Q WNS5.6-1.0/115/70-Y.Q WNS7.0-1.0/115/70-Y.Q WNS10.5-1.25/115/70-Y.Q WNS14.0-1.25/115/70-Y.Q
Rated thermal power kcal/h 60X10^4 120X10^4 180X10^4 240X10^4 360X10^4 480X10^4 600X10^4 900X10^4 1200X10^4
Heating area 6000 12000 18000 24000 36000 48000 60000 90000 120000
Circulating water volume
m^3/h 24 48 72 96 80 107 133 200 267
Rated inlet/outlet temperature °C 95/70
115/70
Hot water output of bath furnace kg/h 15000 30000 45000 60000 90000 120000 150000 225000 300000
Fuel Consumption diesel oil Kg/h 61.0 122.0 182.9 243.9 365.9 487.8 609.8 914.6 1219.5
natural gas Nm^3/h 67.0 134.0 201.0 267.9 410.9 535.9 669.9 1004.8 1339.7
coal gas Nm^3/h 136.1 272.1 408.2 544.2 816.3 1088.4 1360.5 2040.8 2721.1
Thermal power
%
94-96

Power requirements

V/Hz 380/50
Rated outlet pressure
MPa
1.0
1.25
weight

t

4.18 6.1 7.8 10.8 15.9 18.7 19.9 30.3 43.7
External dimensions

long

mm 3857 4600 4772 5472 6560 7030 7630
8450 9040
wide mm 2310
4600 2573 2573 3200 3290 3390 3800 4260
tall mm
2600 3600 4100 4100 4400 4700 4700 4900 5400
Transport dimensions long mm 3020 3750 3672 4272 5240 5950 6550 6800 7490
wide mm 1880 2195 2140 2325 2580 2680 2900 3100 3560
tall mm 2150
2390 2560 2844 3090 3230 3230 3375 3780
Diameter of sewage outlet mm 50
50 50 50 50 50 50 50 50
Inlet/outlet diameter mm 100 100 125 125 150 200 200 250 250
Outer diameter of brine outlet mm 300 350 450 450 550 550 700 900 900
remarks
Two round trips

Integrated condensing low nitrogen atmospheric hot water boiler parameters



Project model

CWNSL0.7-95/70-YQ CWNSL1.4-95/70-YQ CWNSL2.1-95/70-YQ CWNSL2.8-95/70-YQ
Rated thermal power kcal/h 60X10^4 120X10^4 180X10^4 240X10^4
Heating area 6000 12000 18000 24000
Circulating water volume
m^3/h 24 48 72 96
Rated inlet/outlet temperature °C 95/70
Hot water output of bath furnace kg/h
Fuel Consumption diesel oil Kg/h 61 122 182.9 243.9
natural gas Nm^3/h 67 134 210 267.9
gas Nm^3/h 136.1 272.1 408.2 544.2
Thermal power
%
94-96

Power requirements

V/Hz 380/50
Rated outlet pressure
MPa
0
weight

t

3.2 5.3 74 8.3
External dimensions

long

mm 3460 4690 5350 5650
wide mm 1820
2195 2125 2125
tall mm
2110 2418 3426 3426
Transport dimensions long mm 2620 3860 4250 4550
wide mm 1820 2195 2125 2125
tall mm 2110
2110 2558 2558
Diameter of sewage outlet mm 50
50 50 50
Inlet/outlet diameter mm 100 100 125 125
Outer diameter of brine outlet mm 300 350 450 450
notes
Two round trips



The above parameters do not have contractual nature and should be subject to the specific terms of the contract

The fuel consumption is the value after installing the condenser; Fuel calorific value: heavy oil 9860kcal/kg, diesel 10250kcal/kg, natural gas 9140kcal/Nm3, liquefied petroleum gas 24998kcal/Nm3, city gas 4500kcal/Nm3; Due to the continuous improvement of technology, any changes will not be notified; Please request detailed parameters from Fangkuai headquarters.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!