technical parameter |
LS 487 |
LS 477 |
||||||
Measurement benchmark Linear expansion coefficient
|
DIADUR glass grating, grid spacing of 20µm
αtherm ≈8 x 10-⁶ K-¹(Installation method)I/II);With mounting plate:αtherm9 x10-⁶ K-¹(Installation method)III)
|
|||||||
Accuracy level* |
±5 µm; ±3 µm |
|||||||
Measurement length ML*Unit mm |
For grating rulers up to ML 1240, the installation board * is optional, while for grating rulers above ML 1340, it is mandatory 70 120 170 220 270 320 370 420 470 520 570 620 670 720 770 820 920 1240 1540 1840 2040 |
|||||||
Reference point* LS 4x7 LS 4x7 C |
Distance encoding |
|||||||
Interface |
1 VPP |
TTL |
||||||
Internal subdivision multiple* Signal cycle |
– 20 µm |
5-fold – |
10-fold – |
20-fold – |
||||
Diagnostic interface |
simulation |
– |
||||||
Deadline frequency –3 dB |
≥160 kHz |
– |
– |
– |
||||
Scanning frequency* Edge spacing a |
– |
100 kHz ≥0.5 µs |
50 kHz ≥1 µs |
100 kHz ≥0.25 µs |
50 kHz ≥0.5 µs |
25 kHz ≥1 µs |
50 kHz ≥0.25 µs |
25 kHz ≥0.5 µs |
Measure step distance |
Depends on the subdivision magnification |
1 µm1) |
0.5 µm1) |
0.25 µm1) |
||||
Electrical connection |
A separate adapter cable (1 m/3 m/6 m/9 m) can be connected to the installation block |
|||||||
Cable length2) |
≤150 m |
≤100 m |
||||||
No load power supply voltage |
DC 5 V ±0.25 V/< 120 mA |
DC 5 V ±0.25 V/< 140 mA |
||||||
Movement speed |
≤120 m/min |
≤ 120 m/min |
≤ 60 m/min |
≤ 120 m/min |
≤ 60 m/min |
≤ 30 m/min |
≤ 60 m/min |
≤ 30 m/min |
Required motion force |
≤5 N |
|||||||
Vibration55 Hz to 2000 Hz
to attack11 ms
acceleration
|
No installation board:≤100 m/s²(EN 60068-2-6)
With installation plate, the cable outlet is on the right side:≤200 m/s²,left:100 m/s² (EN 60068-2-6)
≤300 m/s²(EN 60068-2-27)
Along the measurement direction≤100 m/s²
|
|||||||
working temperature |
0 °C to 50 °C |
|||||||
Protection levelEN 60 529 |
If it meets the installation instructions in the sample, it should be IP 53. If the sealed air connected to DA 400 is IP 64 |
|||||||
weight |
0.4 kg+0.5 kg/m measuring length |
|||||||
* Please select when placing an order
1)After 4th harmonic subdivision in subsequent electronic circuits
2)Heidenhain Cable
|