VIP member
Korean Eilin Acme 9000 HPLC
Young Lin Acme 9000 HPLC is a third-generation Young LIn HPLC developed based on 13 years of experience and technology in providing over 2000 HPLC uni
Product details
Gradient solvent transfer pump
Excellent flow velocity accuracy (less than ± 0.1%)
Wide range flow rate (standard: 0.001~16ml/min)
Automatic cleaning function
Multiple applications (analysis, semi preparation of narrow aperture)
Built in Gradient Controller
RS-232 digital control and frequency control for pumps from other manufacturers
Up to 3 units can be connected in parallel to form a high-voltage gradient mode
Excellent flow velocity accuracy (less than ± 0.1%)
Wide range flow rate (standard: 0.001~16ml/min)
Automatic cleaning function
Multiple applications (analysis, semi preparation of narrow aperture)
Built in Gradient Controller
RS-232 digital control and frequency control for pumps from other manufacturers
Up to 3 units can be connected in parallel to form a high-voltage gradient mode
*Gradient pump
Stable flow rate and operating pressure
Pump head volume: 64ul
Automatic cleaning function
Wide range flow rate: 0.001ml/min-10ml/min
Flow accuracy: 2% (1ml/min)
Flow accuracy: 0.2% (RSD)
*Vacuum degassing mixer
Using Double Degassing technology for complete vacuum degassing
4+1 channels, capable of degassing the mixed liquid again
Can be connected to gradient pumps and can use up to 4 solvents
Maximum flow rate: 5ml/min/channel
Stable flow rate and operating pressure
Pump head volume: 64ul
Automatic cleaning function
Wide range flow rate: 0.001ml/min-10ml/min
Flow accuracy: 2% (1ml/min)
Flow accuracy: 0.2% (RSD)
*Vacuum degassing mixer
Using Double Degassing technology for complete vacuum degassing
4+1 channels, capable of degassing the mixed liquid again
Can be connected to gradient pumps and can use up to 4 solvents
Maximum flow rate: 5ml/min/channel
*UV/VIS dual wavelength detector
Simultaneously detecting dual wavelengths
Multiple applications (analysis, semi preparation, and narrow aperture)
RS-232 digital control
Front end installation of lights and flow pool, easy to install and maintain.
Simultaneously detecting dual wavelengths
Multiple applications (analysis, semi preparation, and narrow aperture)
RS-232 digital control
Front end installation of lights and flow pool, easy to install and maintain.
*UV detector
Wavelength range: 190-600nm
High wavelength reproducibility: 0.1nm
Wavelength accuracy: ± 1.0nm
RS-232 digital control
Wavelength range: 190-600nm
High wavelength reproducibility: 0.1nm
Wavelength accuracy: ± 1.0nm
RS-232 digital control
*Column temperature box
Provide reliable HPLC analysis results
Reduce analysis time, wide range ground division control (5~85 ℃)
High security
Easy to install chromatography column (maximum 30 cm)
RS-232 digital control
*Autochro-2000 Data Workstation SystemProvide reliable HPLC analysis results
Reduce analysis time, wide range ground division control (5~85 ℃)
High security
Easy to install chromatography column (maximum 30 cm)
RS-232 digital control
Compatible with MS Windows XP
Designed to comply with GMP, International standards such as GLP
Modular design, high stability
Reverse control gradient pump, equal gradient pump, UV/visible light detector, single wavelength detector, column temperature box and data acquisition
Collect data from differential detectors and other manufacturers' detectors using A/D data modules
Online inquiry