Axis transmitter KINAX 3W2
▶Product Introduction
The KINAX 3W2 angular position axis transmitter can be installed.
Convert the axis position into a load independent DC signal and correspond it proportionally to the angular axis position.
▶Product Features
•Compact angular position transmitter can be installed on other devices
•The capacitance scanning system provides absolute position immediately after activation
•No wear and tear, low annual maintenance costs, and can be installed in any location
•Zero point and measurement range adjustable
•Small starting torque < 0.001Ncm
•The impact of small bearing operation is less than 0.1%
•Explosion proof protection "intrinsic safety" Ex ia IIC T6 is available
•Can be installed in hazardous areas
•Suitable for ocean going vessels that comply with GL standards
▶technical data
•Measurement range: 0... 10 °, 0 … 30°, 0 … 60°, 0 … 90°, 0 … 180°,0 … 270°
•Measurement output: 0... 1 mA, 0 … 5 mA, 0 … 10 mA, 0... 20 mA, 4... 20 mA, each with 3 or 4-wire connection, 4... 20mA with 2-wire connection
•Power supply: 12... 33V DC (/non intrinsic safety version), 12... 30V DC (/intrinsic safety version)
•Remaining ripple of output current:< 0.3% p.p.
•Maximum residual ripple: 10% p.p. (must be below 12V)
•Accuracy: Error limit ≤ 0.5% for range 0... ≤ 150 ° to 0... 270 °, error limit ≤ 1.5% for range 0...>150 °
•Repeatability:< 0.2%
•Electrical connection: Solder pads (protection level IP00 compliant with EN60529), with spiral terminal connection printing, AMP connection printing, and pad connection printing Printing with trans type U-wave diode connection
▶Range
•Starting torque: < 0.001Ncm with 2mm axis,<0.03Ncm with 6mm axis 1/4 respectively“
•Gap influence: ± 0.1%
•Drive shaft diameter: 2mm, 6mm or 1/4“
•Allow static load on the shaft:
•Installation location: Any
•Material: Chromium aluminum
•Axis: Rust proof hardened steel
•Weight: Approximately 100g,About 3.9kg (with additional gear)
•Climate grade: Standard (Non Ex): Temperature -25...+70 ° C, relative humidity ≤ 95%, non condensing.
•With improved climate rating (Non Ex): temperature -40...+70 ° C, relative humidity ≤ 95%, non condensing.
•Explosion proof protection: Temperature range from T6 to 40...+55 ° C, temperature range from T5 to 40...+70 ° C, temperature range from T4 to 40...+75 ° C
•Shell protection: IP50 meets EN60529 standard
•Jitter: IEC 60 068-2-6, 50 m/s2/10... 200 Hz (in 3 directions every 2 hours)
•Vibration: IEC 60 068-2-27, ≤ 500 m/s2 (10 pulses per axis and direction)
•Electromagnetic adaptability: The standard is applicable to the anti-interference degree EN61000-6-2 and the observation of interference emission EN61000-6-4
•Explosion protection: Intrinsic safety Ex II 2G/Ex ia IIC T6 complies with EN 60 079-0:2006 and EN 60 079-11: two thousand and seven
▶Explosion proof protection data (protection type 'intrinsic safety')
▶Auxiliary transmission
The best auxiliary transmission device KINAX WT707 is suitable for multi circle applications. Choosing the correct gear rotation ratio can achieve 1600 revolutions per minute. Users can choose auxiliary transmission with gear speed ratios ranging from 2:1 to 1600:1.
Using a special seawater resistant design, the KINAX WT707 can be applied in extreme environmental conditions. The special steel casing makes the KINAX WT707 particularly suitable for corrosive media such as seawater, alkaline solutions, acids, and cleaning agents.
▶files recording
▶authentication
▶ External dimensions