Air flow meter price
KH-LUGB air flow meterAir flow meter priceIts characteristics are small pressure loss, large measurement range, high accuracy, and it is almost unaffected by parameters such as fluid density, pressure, temperature, viscosity, etc. when measuring volumetric flow rate under working conditions. No movable mechanical parts, therefore high reliability and low maintenance. The instrument parameters can remain stable for a long time. This instrument uses piezoelectric stress sensors with high reliability and can operate within a temperature range of -20 ℃ to+350 ℃. It has both analog standard signals and digital pulse signal outputs, making it easy to use in conjunction with digital systems such as computers. It is a relatively advanced and ideal flowmeterVortex flowmeter/air flowmeter prices.
The pulse frequency signal output by the integrated flow meter VSF is not affected by fluid properties and composition changes, that is, the instrument coefficient is only related to the shape and size of the vortex generator and pipeline within a certain Reynolds number range. However, as a flowmeter in material balance and energy measurement, it is necessary to detect mass flow rate. At this time, the output signal of the flowmeter should simultaneously monitor volume flow rate and fluid density. Fluid properties and components still have a direct impact on flow measurement.
This flowmeter is a new type of flowmeter used for measuring fluid flow in closed pipelines based on the Karman vortex principle. Due to its excellent medium adaptability, it can directly measure the volumetric flow rate of liquefied gas, air, gas, water, and liquid without temperature and pressure compensation. Equipped with temperature and pressure sensors, it can measure standard volumetric flow rate and mass flow rate, making it an ideal alternative to throttling flow meters.
To improve the high temperature resistance and vibration resistance of the flowmeter, our company has recently developed the Lugb improved flow sensor. Due to its structure and material selection, the sensor can be used in harsh working conditions such as high temperature (350 ℃) and strong vibration (≤ 1g).
In practical applications, large flow rates are often much lower than the upper limit value of the instrument, and with changes in load, small flow rates often fall below the lower limit value of the instrument. To solve this problem, it is usually necessary to reduce the diameter at the measuring point to increase the flow velocity at the measuring point, and use smaller diameter instruments to facilitate the measurement of the instrument. However, this variable diameter method requires a straight pipe section of at least 15D in length between the variable diameter pipe and the instrument for rectification, making processing and installation inconvenient. Our company has developed an LGZ variable diameter rectifier with a curved longitudinal section, which has multiple functions such as rectification, increasing flow velocity, and changing flow velocity distribution. Its structural size is small, only one-third of the inner diameter of the process pipe, and it is integrated with the flow meter. It not only does not require an additional straight pipe section, but also reduces the requirements for the straight pipe section of the process pipe, making installation very convenient.
For the convenience of use, the locally displayed flow meter powered by batteries adopts micro power consumption high-tech. It can operate continuously for more than a year using lithium battery power supply, saving the procurement and installation costs of cables and display instruments. It can display instantaneous flow, cumulative flow, etc. on site. The production selection of temperature compensated integrated industrial sludge flowmeter also includes a temperature sensor, which can directly measure the temperature of saturated liquefied gas and calculate the pressure, thereby displaying the mass flow rate of saturated liquefied gas. The temperature pressure compensation integrated type is equipped with temperature and pressure sensors, which can directly measure the temperature and pressure of the gas medium for gas flow measurement, thereby displaying the standard volume flow rate of the gas.
Vortex flowmeter/air flowmeter pricesProduct Features
- Adopting a low-power CPU central processing unit and LCD display, with low power consumption.
- Easy to install, very convenient to maintain, long calibration cycle, usually two years.
- The structure is simple and sturdy, with no movable parts, making it highly reliable for long-term operation.
- Wide range: Normal range 1∶10The range ratio can reach 1∶15.
- Low pressure loss, low operating costs, and more energy-saving significance.
- Within a certain Reynolds number range, the output signal is not affected by the physical properties and composition changes of the measured medium, and the instrument coefficient is only related to the shape and size of the vortex generator. After replacing the accessories, there is generally no need to recalibrate the instrument coefficient.
- It can be displayed on-site, transmitted over long distances, and connected to computer control systems.
- The detection probe does not directly contact the measured medium, resulting in more stable performance.
- The integrated design of temperature and voltage compensation and the current output are both of the optoelectronic isolation type, which has good resistance to common mode interference suppression capability.
Air flow meter, air flow meter priceTechnical Specifications
- Temperature range: Piezoelectric type: -25 ℃~+350 ℃
- Capacitive: -40 ℃ to+450 ℃
- Connection method: DN15 to DN300 are flange clamp type or flange connection type
DN300DN1000 is a plug-in type
DN1000The above can be specially ordered
- Flow rate range: Steam: 7m/s to 70m/s
液体: 0.7m/s~7m/s
Gas: 5-35m/s
- Pressure specification: PN1.6MPa; PN2.5MPa; PN4.0MPa
Higher pressure specifications can be specially customized
- Pressure loss coefficient: Cd ≤ 2.6
- Accuracy: Flange mounted, flange connected: Level 0.5, Level 1.0, Level 1.5
Insertion type: Level 1.5, Level 2.5
- Supply voltage: Sensor: DC12V or DC24V Transmitter: DC24V
On site display type: DC24V, DC12V or 3.6V lithium battery
- Output signal: Sensor: Pulse frequency signal 2-3000Hz
Low level ≤ 1V High level ≥ 6V
Transmitter: two-wire 4-20mA DC current signal
- Seismic performance: piezoelectric type ≤ 0.2g
Capacitive ≤ 2.0g
- Environmental temperature: Sensor: -30 ℃~+65 ℃
Transmitter: On site display -10 ℃~+50 ℃
- Environmental humidity: Relative humidity of 5-85% RH
- Signal transmission distance: ≤ 500m
- Length of straight pipe section: upstream ≥ 10D
Downstream ≥ 5D
- Explosion proof grade: Exia IICT2-T5 intrinsically safe explosion-proof
- Protection level: Regular IP65
Submersible type IP68
- Instrument material: The instrument shell is made of aluminum alloy, and the body part is made of stainless steel 304 material. Special materials can also be used according to user requirements
selection
- Clearly define the inner diameter of the pipeline, the name of the measuring medium, the state of the medium, the working pressure, the working temperature, and the process flow range (small, normal, and large operating flow rates m ³/h). Non operating flow rates can be customized according to the parameters provided by the user.
- According to the above parameters, refer to the flow range reference table and select the size of the pipe diameter. The large flow rate used should not be less than 50% of the rated large flow rate of the flowmeter
Air flow meter price, air flow meter selection
brand |
dividing line |
Structural method |
Path code |
Model Number |
temperature and pressure compensation |
output signal |
measuring medium |
Installation method |
Table body material |
power supply |
pressure |
fluid temperature |
precision |
Instructions |
|
KH-LUGB |
|
|
|
|
|
|
|
|
|
|
|
|
|
brand |
|
|
- |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Y |
|
|
|
|
|
|
|
|
|
|
|
integrated |
||
F |
|
|
|
|
|
|
|
|
|
|
|
split-type |
|||
|
XX |
|
|
|
|
|
|
|
|
|
|
50Representing DN50 |
|||
|
|
B |
|
|
|
|
|
|
|
|
|
piezoelectric |
|||
|
E |
|
|
|
|
|
|
|
|
|
capacitance |
||||
|
Y |
|
|
|
|
|
|
|
|
have |
|||||
|
N |
|
|
|
|
|
|
|
|
none |
|||||
|
F1 |
|
|
|
|
|
|
|
Isolation 4-20mA |
||||||
|
F2 |
|
|
|
|
|
|
|
pulse |
||||||
F3 |
|
|
|
|
|
|
|
RS-485/232 |
|||||||
F4 |
|
|
|
|
|
|
|
other |
|||||||
|
J1 |
|
|
|
|
|
|
liquid |
|||||||
|
J2 |
|
|
|
|
|
|
gas |
|||||||
J3 |
|
|
|
|
|
|
saturated steam |
||||||||
J4 |
|
|
|
|
|
|
superheated steam |
||||||||
|
L1 |
|
|
|
|
|
Flange card installation |
||||||||
|
L2 |
|
|
|
|
|
flange connection |
||||||||
L3 |
|
|
|
|
|
Simple insertion type |
|||||||||
L4 |
|
|
|
|
|
Ball valve plug-in type |
|||||||||
|
C |
|
|
|
|
carbon steel |
|||||||||
|
F |
|
|
|
|
stainless steel |
|||||||||
|
D1 |
|
|
|
DC12V |
||||||||||
|
D2 |
|
|
|
DC24V |
||||||||||
D3 |
|
|
|
Internal 3.6V power supply |
|||||||||||
|
P1 |
|
|
1.6MPa |
|||||||||||
|
P2 |
|
|
2.5MPa |
Please note for other pressures: P plus pressure parameters are sufficient |
||||||||||
P3 |
|
|
4.0MPa |
||||||||||||
|
T1 |
|
Normal: -20 to+250 ℃ |
||||||||||||
|
T2 |
|
High temperature: 100~+380 ℃ |
||||||||||||
|
E-xx |
E0.5Indicating an accuracy level of 0.5 |
|||||||||||||
