Friendly reminder:
The so-called statutory thin-layer chromatography scanner refers to a device that complies with the detailed provisions of the Thin Layer Chromatography Scanning Method in the 2005 Pharmacopoeia, the Thin Layer Chromatography Scanning Method in the Chinese Drug Inspection Standard Operating Procedures, and the Thin Layer Chromatography Scanner Verification Regulations in the Drug Inspection Instrument Verification Regulations. It consists of a deuterium tungsten lamp combination light source, a monochromator, and an X-Y mobile platform, with wavelength accuracy of ≤± 5nm and background drift of ≤± 0.5Abs; Baseline noise: ≤± 0.02Abs; Repetitive error: RSD ≤ 2.0%; The scanning direction is a non imaging type that scans from bottom to top along the unfolding direction.
Main advantages:
1. Having national metrological certification, * meeting relevant requirements, and using without risk;
2. Meets all requirements of the national "Verification Regulations" and the method is legal;
3. Having an ISO9001:2000 quality assurance system, stable performance, and minimal malfunctions;
4. All thin-layer quantitative varieties and methods in the pharmacopoeia are pre-set in the machine and can be called at any time, which is very convenient;
5. Accurate quantification, reasonable price, and high cost-effectiveness;
6. High degree of automation, simple operation, suitable for batch analysis;
Instrument composition:
1. Host (including light source, grating monochromator, mobile platform);
2. TStar-2100 Professional Thin Layer Chromatography Workstation;
Instrument accessories (optional):
1. SP-II electric thin-layer sampling instrument;
2. TS-II ultra-fine electric spray;
3. TD-II automatic thin layer laying machine;
4. TK-10 Electronic Spreader;
Instrument specifications:
1. Spectral range: 190-700nm (can be automatically set);
2. Wavelength accuracy: ≤± 1nm;
3. Repetitive error: RSD ≤ 2.0%;
4. Monochromator: holographic grating;
5. Light source: deuterium tungsten lamp combination light source;
6. Measurement methods: reflection method, fluorescence method, absorption method;
7. Software environment: WIN2000/WINXP;
8. Quantitative methods: external standard method, internal standard method, normalization method;
9. Record content: Thin layer chromatography scan chart, peak area, working curve, regression equation, correlation coefficient, measurement results;
Pre configurable thin-layer analysis methods:
1. All thin-layer scanning quantitative methods in the 2000 edition of the Chinese Pharmacopoeia;
2. All thin-layer scanning quantitative methods in the 2005 edition of the Chinese Pharmacopoeia;
3. All thin-layer scanning quantitative methods in the 2010 edition of the Chinese Pharmacopoeia;
For higher analysis requirements, please choose our company's KH-3000 full wavelength.