Japanese Sony Magnescale Controller MJ100/MJ110
High response speed interpolator for controlling position
Product Introduction:
High response speed controllerMJ100It can generate A/B 90 degree phase difference output signals with a resolution of 2-125 microns. Matching products: PL25,PL60.

model |
MJ100 |
MJ110 |
|
Power Supply |
5V(4.5V-6V) |
12V-30V(11V-31V) |
|
Power consumption |
4W |
3W |
|
Output interface |
Line driver (compliant with EIA-422) |
Open collector (1OL=50 mA max) |
|
output signal |
A/B 90 degree phase difference signal, Z-phase output signal, U/V/W phase output signal, and warning signal |
A/B 90 degree phase difference signal, Z-phase output signal, and warning signal |
|
Number of divisions |
1000960800512500480400256240200128120100, 80, 64, 40 and half of the above data when the collaborative reference point specification cannot be achieved |
||
Maximum response frequency |
1000 electrical partitions |
6KHz (1800m/min when connected to PL25, 720m/min when connected to PL60) |
600KHz (180m/min when connected to PL25, 72m/min when connected to PL60) * 1 |
500 electrical partitions |
15KHz (4500m/min when connected to PL25, 1800m/min when connected to PL60) |
1.5KHz (450m/min when connected to PL25, 180m/min when connected to PL60) |
|
200 electrical partitions |
42KHz (12600m/min when connected to PL25, 5000m/min when connected to PL60) |
4.0KHz (1200m/min when connected to PL25, and 480m/min when connected to PL60) |
|
120 electrical partitions |
40KHz (21000m/min when connected to PL25, 8400m/min when connected to PL60) |
7.4KHz (2220m/min when connected to PL25, 888m/min when connected to PL60) |
|
Maximum phase difference |
100ns |
1μs |
|
Warning * 2 |
Speed warning (minimum phase difference time or maximum response frequency) Level warning (0.4Vp-p or lower; Minimum warning time: approximately 400ms) |
||
System startup time |
Within 0.5 seconds after connecting to the power supply |
||
external diameter |
138 * 93 * 26 (mm) including protrusions |
||
Compatible read head group |
PL25/PL60 |
||
Operating temperature |
0℃-45℃ |
||
Storage temperature |
-20℃~60℃ |
||
weight |
350g |
||
The attachments provided |
User manual, output connector, connector cover, fixing screws |
||
option |
SET-P16-1 (for external reference point use) ruler extension line, external reference point extension line, output connector with cable attached |
*1: The values of the minimum phase difference of 1 μ s may vary depending on the length of the output line.
*2: The warning function cannot operate when abnormal cancellation occurs due to coil breakage.
Magnescale (formerly SONY) related products
Grating ruler|Magnetic scale
Scale SR127
SR128(GB-A)
SR138(GB-ER)
SL130/SL110
SL331/PL60
SL700/SL710/SL720
SR74/SR75
SR77
SR84/SR85
SR87
PL20C
PL25-3
PL81/PL82
PL60-3
PL101
Digital Gauge
DG10B/DG10N/DG10P
DG25B/DG25P/DG25S
DG50B/DG50P
DG100B/DG100P/DG100N
DG110B/DZ531/DZ581
DG155BP/DG155P/DG205BP/DG205P
DG805/DG810
DK830S
DK110NLR5
DK155/DK205
DK50/DK100
DK10/DK25
DK802A/DK802B
DK805A/DK805B
DK812A/DK812B
DT12N/DT12P
DT32N/DT32P,DT32NV/DT32PV
DT512N/DT512P
DL310B/DL330B
DE12BR/DE30BR
U60B-F
U30B-F
U12B-F
Digital Display Control Unit Displays
LG20
LT10A
LT11A
LT20A
LT30
LH70
LH71
LH72
LY71
LY72
Signal processing unit Detector
MG10/MG20/MG30
MG40/MG41/MG42/MG43
MT12/MT13/MT14
MJ100/MJ110
MJ620
MJ820/MJ821
MJ830/MJ831
Roll detection system
MD20B
MD50-2N/MD50-4N
MSS-976R
HA-705LK
MK3
Related Accessories
SET-B3/SET-K2
SET-P15
SET-P16
DZ/LZ/SZ/CE
PH-100/PH-500
PG-104