Working principle
This product is a boiler drum level gauge based on the principle of time travel. The probe emits high-frequency pulses and propagates along the rod probe. When the pulse
When encountering the surface of the material, it is reflected back and received by the receiver inside the instrument, and the distance signal is converted into a level signal. Adopting a special approach
The relevant demodulation technology can ensure the identification of the time interval between the transmitted pulse and the received pulse, thereby further developing the technology from the antenna to the measured signal
The distance between the surface of the medium.
Product Features
The intelligent boiler drum level gauge adopts new generation technology and has the following advantages
·Adopting highly accurate compact contact sensors with no movable parts, the structure is sturdy and durable.
·The detachable design of the bypass pipe and instrument body provides significant economic advantages for replacement and maintenance.
·Using manufacturers with welding qualifications for pressure vessels to provide bypass pipes, conducting pressure tests one by one, ensuring safety and reliability.
·Energy concentration and stronger anti-interference ability greatly improve measurement accuracy and stability.
·Small size, easy to install on site, and better adaptability for measuring small and special tanks.
·Small size, easy to install on site, and better adaptability for measuring small and special tanks.
·The measurement blind spot is small, which maximizes the measurement range.
·The signal remains stable when measuring surface fluctuations.
·The first radar in China to add LCD backlight function, making debugging more convenient under low light conditions.
Support on-site adjustment, customers can adjust the range, blind spot, language, damping time according to the situation, with a full Chinese menu and waveform display,
The functions of false echo and learning belong to the leading level in China.
Technical Parameter
·Shell
die-casting aluminum
·Sealing of the connection of the shell cover
silicon rubber
·Shell window
polycarbonate
Power supply parameters
·Two wire system
Standard (16~36) VDc, intrinsic safety type (21.6~26.4) vDc
·Allow ripples
-<100HZ USS<1V, - (less than 100~100K) HZ USS<10mV
·Four wire system, two bedroom
Intrinsic safety+explosion-proof (21.6-26.4) VDC. (19.8-24.2) VA
·Power consumption
max. 1VA .1W
·Cable entry/plug
M20x15 cable entry, blind M20x1.5
·Applicable cables
Diameter (5-9) mm shielded cable, user wire cross-section 2.5mn
Output parameters
·Output signal
4 ~20Ma/HART
·Resolution
1. 6ua
·Fault signal
The current remains unchanged; 20.5mA; 22mA; 3.9mA
·Integral time
(0-40)s, adjustable
characteristic parameter
·Blind spot
Antenna end
·Ripple frequency converter
The frequency is 500MHz-1.8GHz
·Measurement interval
Approximately 1 second (depending on parameter settings)
·Adjust time
Large 1 second (depending on parameter settings)
·Display resolution
1mm
·Accuracy
± 3mm/± 5mm (see enterprise standard accuracy diagram)
·Relative humidity
95%
·Vibration resistance
Mechanical vibration 10m/s2, (10~150)Hz
·Remarks Information
The standard flange size refers to GB/T9119-2000
Exterior structure
Order Selection Table