Beckman Coulter HIAC 9703+Laboratory Liquid Particle Counter
The HIAC 9703+liquid particle counter is a leader in quality control and research applications in the pharmaceutical industry under USP<788>. HIAC9703+is designed specifically for your liquid particle counting application needs, highly configurable, and easy to use. PharmSpec software makes data management more convenient and ensures that the security of the environment complies with the requirements of 21 CFR Part 11 regulations.
Advantages of choosing HIAC 9703+for liquid particle counter
The smallest sample in the industry: a complete set of tests can be completed with only 1mL of product.
Manage all your application requirements: can handle a full range of sample volumes, from 1 milliliter to over 1000 milliliters, based on pre configured USP, EP, JP, and KP testing routines.
Eliminate uncertainty based on data anomalies: When bubbles or sensors are contaminated and may affect particle counting results, an alarm notification will be issued.
The handling of samples is safe and reliable: small bottle holders are used to ensure that expensive samples are not wasted.
Easy to configure for maximum flexibility: Choose an optimal flow rate and use interchangeable sensors to detect particle sizes ranging from 0.5 to 600 μ m.
Avoiding high cost downtime: On site service can effectively reduce downtime - there is no need to transport your instrument, and it will automatically notify when your instrument needs routine maintenance.
Eliminating your concerns about data loss: The recovery function for lost data can protect test data in the event of an unexpected power outage. PharmSpec allows operators to schedule the time for backing up the database to a secure network site.
Verification services for HIAC particle counters: SOP assistance and IQ/QQ verification services, utilizing our professional skills to make your system usable once it is removed from the packaging box.
Product parameters
weight
|
10.7 kg kg
|
size
|
343mm (length) x 337mm (width) x 482mm (height)
|
Operating temperature
|
5 to 40 ° C; Relative humidity ranging from 0 to 80%, no condensation
|
sample temperature
|
5 to 40 ° C
|
power supply
|
100/230 VAC, 50/60 Hz, 67 W at 115/230 VAC
|
Viscosity limit
|
<50 CP
|
Gap in sampling bottle
|
153 mm
|
Volume accuracy
|
> 95%
|
Flow velocity accuracy
|
> 95%
|
Sample flow rate
|
10 to 100 milliliters per minute; The actual flow rate of the system is determined by the flow rate of the sensor
|
Pre extraction volume of probe
|
For a probe of 81 L × 1.2I. D mm, the volume is 0.091 ml For a probe of 154 L × 1.2 mm I.D., the volume is 0.172 ml For 140 L × 6.35I The D mm probe is 1.57mL (5.5 x 0.25 inches) - large caliber
|
PharmSpec 3 software for HIAC 9703+liquid particle counter
Processor
|
Pentium ® 1.0 GHz
|
Operating System
|
Windows ® XP, Windows Vista with Service Pack 3 or higher ® Windows 7 with Service Pack 2 or higher (32-bit)
|
Memory
|
512MB RAM
|
Hard drive
|
2GB hard drive space
|
Optical drive
|
CD drive, DVD drive, USB port or network connection, used for installing software
|
Display
|
High quality VGA video adapter and monitor, 1024 x 768 or higher resolution
|
Power supply
|
Continuous power supply (UPS)
|
Detachable optical drive
|
A detachable optical drive can back up data, such as a recordable CD or a network server, which can back up data from a computer's hard drive
|
Printer
|
Color printer, capable of printing at a resolution of 300dpi
|
COM port
|
The USD port can be connected to the particle counting system
|
Software
|
Internet Explorer 6.0 or higher and Microsoft ® Excel ®, Word ® Or Adobe ® Acrobat ® (Access PharmSpec report)
|
application area
USP<788>/Insoluble particles in injections and injection liquids
HIAC 9703+Liquid Particle Counting System
HIAC PharmSpec Liquid Particle Counting Software
HIAC HRLD Liquid Particle Counting Sensor
HIAC MC05 Liquid Particle Counting Sensor (Submicron Scale)
Regulatory link
USP <788>
USP <789>
USP <797>
USP<789>Insoluble particles in ophthalmic solutions
HIAC 9703+Liquid Particle Counting System
HIAC PharmSpec Liquid Particle Counting Software
HIAC HRLD Liquid Particle Counting Sensor
HIAC MC05 Liquid Particle Counting Sensor (Submicron Scale)
USP<797>Drug Preparation - Sterile Formulations
HIAC 9703+Liquid Particle Counting System
HIAC PharmSpec Liquid Particle Counting Software
HIAC HRLD Liquid Particle Counting Sensor
HIAC MC05 Liquid Particle Counting Sensor (Submicron Scale)
Liquid particle counting release test standard
USP<788>Insoluble particles in injections and injectable liquids
USP<789>Insoluble particles in ophthalmic solutions
USP<7897>Pharmaceutical Preparation - Aseptic Preparations
www.uspnf.com
www.usp.org
Society for Extraintestinal Drugs
EDQM
PharmSpec software for HIAC 9703+liquid particle counter
Test setup is simple and easy to use
Pressing the button will reveal the pharmacopoeial testing methods for USP, EP, JP, and KP
Customize testing methods using PharmSpec program generator
Everything is safe and the data is reliable
The database can be securely migrated from the old Windows operating system to the new Windows 7 and higher versions
Network backup and archiving can be configured
Fully comply with the requirements of 21 CFR Part 11 regulations
The software is pre configured - no professional knowledge required
Authorized users are free to update USP<788>, USP<789>, EP, JP, or KP pharmacopoeias annually
There are intuitive settings for new users - invalid configurations will trigger an alarm, and calibration expiration will be notified in advance
Early detection of abnormal data
Can use bubble detection and centralized alarm sensors to stop tracking abnormal data
Can confirm all particle counting results; Partial results of incomplete testing will also be recorded
PharmSpec software/firmware update
PharmSpec Update USP 38 787 (Zip) - Upgrades existing USP functionality to the current pharmacopoeia level. This update is only applicable to PharmSpec V3.3.
PharmSpec Update USP 38 788 (Zip) - Upgrades existing USP functionality to the current pharmacopoeia level.
PharmSpec Update USP 38 789 (Zip) - Upgrades existing USP functionality to the current pharmacopoeia level.
PharmSpec Update JP XVI (Zip) - Upgrade the existing JP functionality to the current pharmacopoeia level.
PharmSpec Update EP 7 (Zip) - Updates existing EP functionality to current compendial level.
PharmSpec Update EP8 (Zip) - Upgrade existing EP functionality to the current pharmacopoeia level.
PharmSpec Update KP 11 (Zip) - Upgrade the existing EP functionality to the current pharmacopoeia level.
PharmSpec Update V3.1.4 (Zip) - PharmSpec Update V3.1.4 (Zip) - Updated PharmSpec V3.1.1, The updates on this website are only valid for PharmSpec V3.1.1, V3.1.2, and V3.1.3. Please refer to readme.exe for information on V3.1.2 and V3.1.3