Mine rescue, industrial cooling, farmland irrigation, seawater lifting, ship loading, and also used for fountain landscapes. Hot water submersible pumps are used for hot spring bathing,
It can also be used to extract groundwater from deep wells, as well as for water extraction projects such as rivers, reservoirs, and canals. Mainly used for farmland irrigation and people in high mountain areas
Livestock water can also be used for central air conditioning cooling, heat pump units, cold pump units, urban, factory, railway, mining, and construction site drainage. general flow
The quantity can reach
(5m3~150m3)
Hourly, the lift can reach 10-240 meters
| model |
internet traffic (m3/h) |
pressure (Mpa) |
allow number of rotations (r/min) |
electrical machinery power (kw) |
Necessary gas Corrosion allowance (m) |
Import Law |
Export Law Lantong diameter (mm) |
Allow particles Particle diameter (mm) |
Allow fiber Dimension length (mm) |
| G20-1 | 0.8 | 0.6 | 960 | 0.75 | 4 | 25 | 25 | 1.5 | 25 |
| G20-2 | 1.2 | 1.5 | |||||||
| G25-1 | 2 | 0.6 | 960 | 1.5 | 40 | 32 | 2 | 30 | |
| G25-2 | 1.2 | 2.2 | |||||||
| G30-1 | 5 | 0.6 | 960 | 2.2 | 50 | 40 | 2.5 | 35 | |
| G30-2 | 1.2 | 3 | |||||||
| G35-1 | 8 | 0.6 | 960 | 3 | 65 | 50 | 3 | 40 | |
| G35-2 | 1.2 | 4 | |||||||
| G40-1 | 12 | 0.6 | 960 | 4 | 80 | 65 | 3.8 | 45 | |
| G40-2 | 1.2 | 5.5 | |||||||
| G50-1 | 14 | 0.6 | 720 | 5.5 | 4.5 | 100 | 80 | 5 | 50 |
| G50-2 | 1.2 | 7.5 | |||||||
| G60-1 | 22 | 0.6 | 720 | 11 | 5 | 125 | 100 | 6 | 60 |
| G60-2 | 1.2 | 15 | |||||||
| G70-1 | 38 | 0.6 | 720 | 11 | 150 | 125 | 8 | 70 | |
| G70-2 | 1.2 | 18.5 | |||||||
| G85-1 | 56 | 0.6 | 630 | 15 | 150 | 150 | 10 | 80 | |
| G85-2 | 1.2 | 30 | |||||||
| G105-1 | 100 | 0.6 | 500 | 30 | 200 | 200 | 15 | 110 | |
| G105-2 | 1.2 | 55 | |||||||
| G135-1 | 150 | 0.6 | 400 | 45 | 250 | 250 | 20 | 150 | |
| G135-2 | 1.2 | 90 |
Single stage, performance parameters for gear shifting, electromagnetic speed regulation motor with gear shifting, or continuously variable speed motor with gear shifting
| model | Pressure 0.3Mpa | Pressure 0.6Mpa | Adjustable RPM | ||||||
|
number of rotations (r/min) |
internet traffic (m3/h) |
motor power (kw) |
number of rotations (r/min) |
internet traffic (m3/h) |
motor power (kw) |
number of rotations (r/min) |
internet traffic (m3/h) |
motor power (kw) |
|
| G20-1 | 960 | 0.96 | 0.75-6 levels | 960 | 0.8 | 0.75-6 levels | 125~1250 | 0.1~1.5 | 1.1 |
| 720 | 0.8 | 0.55-8 levels | 720 | 0.5 | 0.75-8 levels | ||||
| 510 | 0.4 | 0.55-4 levels/gearbox | 510 | 0.3 | 0.75-4 levels/gearbox | ||||
| G25-1 | 960 | 2.4 | 0.75-6 levels | 960 | 2 | Levels 1.5-6 | 125~1250 | 0.1~3 | 1.5 |
| 720 | 1.5 | 0.55-8 levels | 720 | 1.27 | Levels 1.1-8 | ||||
| 510 | 1.08 | 0.55-4 levels/gearbox | 510 | 0.9 | 1.1-4 levels/gearbox | ||||
| G30-1 | 960 | 3.6 | Levels 1.5-6 | 960 | 3 | Level 2.2-6 | 125~1250 | 0.2~4 | 2.2 |
| 720 | 2.28 | Levels 1.1-8 | 720 | 1.9 | Levels 1.5-8 | ||||
| 510 | 1.63 | 1.1-4 levels/gearbox | 510 | 1.35 | 1.5-4 levels/gearbox | ||||
| G35-1 | 720 | 4.8 | Level 2.2-8 | 720 | 4.04 | Level 3-8 | 125~890 | 0.3~5 | 3 |
| 510 | 3.36 | 1.5-4 levels/gearbox | 510 | 2.8 | 2.2-4 levels/gearbox | ||||
| 380 | 1.92 | 1.1-4 levels/gearbox | 380 | 1.60 | 1.5-4 levels/gearbox | ||||
| G40-1 | 510 | 6.8 | 2.2-4 levels/gearbox | 510 | 5.6 | 3-4 levels/gearbox | 125~890 | 0.3~10 | 4 |
| 380 | 5.1 | 1.5-4 levels/gearbox | 380 | 4 | 2.2-4 levels/gearbox | ||||
| 252 | 2.65 | 1.1-6 levels/gearbox | 252 | 2.2 | 1.5-6 levels/gearbox | ||||
| G50-1 | 510 | 13.8 | 4-4 levels/gearbox | 510 | 11.5 | 5.5-4 levels/gearbox | 80~750 | 1~18 | 5.5 |
| 380 | 10.2 | 4-4 levels/gearbox | 380 | 7.5 | 5.5-4 levels/gearbox | ||||
| 252 | 5.6 | 3-6 levels/gearbox | 252 | 4.4 | 5.5-6 levels/gearbox | ||||
| G60-1 | 510 | 20.8 | 7.5-4 levels/gearbox | 510 | 16 | 11-4 levels/gearbox | 63~630 | 1~20 | 11 |
| 380 | 15.6 | 7.5-4 levels/gearbox | 380 | 12 | 11-4 levels/gearbox | ||||
| 252 | 7.8 | 5.5-6 levels/gearbox | 252 | 6 | 7.5-6 levels/gearbox | ||||
| G70-1 | 510 | 26 | 11-4 levels/gearbox | 510 | 20 | 11-4 levels/gearbox | 56~560 | 1~22 | 11 |
| 380 | 17 | 7.5-4 levels/gearbox | 380 | 13 | 11-4 levels/gearbox | ||||
| 252 | 9.1 | 7.5-6 levels/gearbox | 252 | 7 | 7.5-6 levels/gearbox | ||||
| G85-1 | 380 | 32 | 11-4 levels/gearbox | 380 | 25 | 15-4 levels/gearbox | 37~370 | 2~24 | 15 |
| 252 | 21 | 7.5-6 levels/gearbox | 252 | 16 | 11-6 levels/gearbox | ||||
| 189 | 11 | 5.5-8 levels/gearbox | 189 | 8 | 11-8 levels/gearbox | ||||
| G105-1 | 380 | 80 | 15-4 levels/gearbox | 380 | 65 | 22-4 levels/gearbox | 29~290 | 3~50 | 22 |
| 252 | 44 | 15-6 levels/gearbox | 252 | 34 | 22-6 levels/gearbox | ||||
| 189 | 29 | 11-8 levels/gearbox | 189 | 22 | 15-8 levels/gearbox | ||||
| G135-1 | 380 | 132 | 37-4 levels/gearbox | 380 | 120 | 45-4 levels/gearbox | 18~180 | 3~56 | 45 |
| 252 | 95 | 30-6 levels/gearbox | 252 | 80 | 37-6 levels/gearbox | ||||
| 189 | 65 | 18.5-6 levels/gearbox | 189 | 53 | 30-8 levels/gearbox | ||||
Dual stage, performance parameters for gear shifting, electromagnetic speed regulation motor with gear shifting, or continuously variable speed motor with gear shifting
| model | Pressure 0.8Mpa | Pressure 1.2Mpa | Adjustable RPM | ||||||
|
number of rotations (r/min) |
internet traffic (m3/h) |
motor power (kw) |
number of rotations (r/min) |
internet traffic (m3/h) |
motor power (kw) |
number of rotations (r/min) |
internet traffic (m3/h) |
motor power (kw) |
|
| G20-2 | 960 | 0.96 | Levels 1.5-6 | 960 | 0.8 | Levels 1.5-6 | 125~1250 | 0.1~1.5 | 1.5 |
| 720 | 0.8 | Levels 1.1-8 | 720 | 0.5 | Levels 1.5-8 | ||||
| 510 | 0.4 | 1.1-4 levels/gearbox | 510 | 0.3 | 1.1-4 levels/gearbox | ||||
| G25-2 | 960 | 2.4 | Levels 1.5-6 | 960 | 2 | Level 2.2-6 | 125~1250 | 0.1~3 | 2.2 |
| 720 | 1.5 | Levels 1.1-8 | 720 | 1.27 | Levels 1.5-8 | ||||
| 510 | 1.08 | 1.1-4 levels/gearbox | 510 | 0.9 | 1.5-4 levels/gearbox | ||||
| G30-2 | 960 | 3.6 | Levels 3-6 | 960 | 3 | Levels 3-6 | 125~1250 | 0.2~4 | 3 |
| 720 | 2.28 | Levels 1.5-8 | 720 | 1.9 | Level 2.2-8 | ||||
| 510 | 1.63 | 1.5-4 levels/gearbox | 510 | 1.35 | 2.2-4 levels/gearbox | ||||
| G35-2 | 720 | 4.8 | Level 3-8 | 720 | 4.04 | Level 4-8 | 125~890 | 0.3~5 | 4 |
| 510 | 3.36 | 2.2-4 levels/gearbox | 510 | 2.8 | 3-4 levels/gearbox | ||||
| 380 | 1.92 | 1.5-4 levels/gearbox | 380 | 1.60 | 2.2-4 levels/gearbox | ||||
| G40-2 | 510 | 6.8 | 4-4 levels/gearbox | 510 | 5.6 | 5.5-4 levels/gearbox | 125~890 | 0.3~10 | 5.5 |
| 380 | 5.1 | 3-4 levels/gearbox | 380 | 4 | 4-4 levels/gearbox | ||||
| 252 | 2.65 | 2.2-6 levels/gearbox | 252 | 2.2 | 3-6 levels/gearbox | ||||
| G50-2 | 510 | 13.8 | 5.5-4 levels/gearbox | 510 | 11.5 | 7.5-4 levels/gearbox | 80~750 | 1~18 | 7.5 |
| 380 | 10.2 | 4-4 levels/gearbox | 380 | 7.5 | 5.5-4 levels/gearbox | ||||
| 252 | 5.6 | 3-6 levels/gearbox | 252 | 4.4 | 5.5-6 levels/gearbox | ||||
| G60-2 | 510 | 20.8 | 15-4 levels/gearbox | 510 | 16 | 15-4 levels/gearbox | 63~630 | 1~20 | 15 |
| 380 | 15.6 | 11-4 levels/gearbox | 380 | 12 | 15-4 levels/gearbox | ||||
| 252 | 7.8 | 7.5-6 levels/gearbox | 252 | 6 | 11-6 levels/gearbox | ||||
| G70-2 | 510 | 26 | 15-4 levels/gearbox | 510 | 20 | 18.5-4 levels/gearbox | 56~560 | 1~22 | 18.5 |
| 380 | 17 | 11-4 levels/gearbox | 380 | 13 | 15-4 levels/gearbox | ||||
| 252 | 9.1 | 11-6 levels/gearbox | 252 | 7 | 11-6 levels/gearbox | ||||
| G85-2 | 380 | 32 | 18.5-4 levels/gearbox | 380 | 25 | 22-4 levels/gearbox | 37~370 | 2~24 | 22 |
| 252 | 21 | 15-6 levels/gearbox | 252 | 16 | 18.5-6 levels/gearbox | ||||
| 189 | 11 | 15-8 levels/gearbox | 189 | 8 | 15-8 levels/gearbox | ||||
| G105-2 | 380 | 80 | 30-4 levels/gearbox | 380 | 65 | 37-4 levels/gearbox | 29~290 | 3~50 | 37 |
| 252 | 44 | 30-6 levels/gearbox | 252 | 34 | 30-6 levels/gearbox | ||||
| 189 | 29 | 22-8 levels/gearbox | 189 | 22 | 22-8 levels/gearbox | ||||
| G135-2 | 380 | 132 | 55-4 levels/gearbox | 380 | 120 | 75-4 levels/gearbox | 18~180 | 3~56 | 75 |
| 252 | 95 | 55-6 levels/gearbox | 252 | 80 | 75-6 levels/gearbox | ||||
| 189 | 65 | 37-8 levels/gearbox | 189 | 53 | 45-8 levels/gearbox | ||||
Performance parameters of single-stage and two-stage coal water slurry working pumps
| Pump type |
internet traffic (m3/h) |
Working pressure (Mpa) |
number of rotations (r/min) |
Gear reduction matching speed regulating motor (kw) |
| G30-2 | ~1 | 1.2 | 30~300 | YCT160/4A-2.2 |
| G35-2 | ~2 | 1.2 | 30~300 | YCT160/4A-2.2 |
| G40-2 | ~3 | 1.2 | 30~280 | YCT160/4A-3 |
| G50-1 | ~4.5 | 0.6 | 28~280 | YCT180/4A-4 |
| G50-2 | ~4.5 | 1.2 | 28~280 | YCT200/4A-5.5 |
| G60-1 | ~6.5 | 0.6 | 25~250 | YCT200/4A-5.5 |
| G60-2 | ~6.5 | 1.2 | 25~250 | YCT200/4B-7.5 |
| G70-1 | ~8 | 0.6 | 25~250 | YCT200/4B-7.5 |
| G85-1 | ~12.5 | 0.6 | 18~180 | YCT225/4A-11 |
| G105-1 | ~20 | 0.6 | 14~140 | YCT225/4B-15 |
| G135-1 | ~35 | 0.6 | 10~100 | YCT250/4B-22 |
explain:
1. The above performance parameters are experimental data obtained during the room temperature water test;
2. For different media and speeds, performance parameters will vary, with flow rate values inversely proportional to concentration and viscosity, and directly proportional to speed;
3. Users must choose the type of pump based on usage requirements, the condition of the conveying medium, and selection principles, or consult with our company's technical department to determine the type of pump.