Widely used | Full membrane water-cooled wall sealing structure | |
To provide production steam for food, printing and dyeing, pharmaceutical, chemical and other enterprises, to provide steam for heating other enterprises, hotels, and also to provide domestic hot water through water tank heating. |
The boiler adopts a full membrane water-cooled wall structure, which has good sealing, low heat dissipation loss, and low thermal inertia, and can achieve rapid start-up and shutdown of the boiler. |
||
![]() |
Excellent matching of combustion system ensures boiler operation status | 9 major safety protection devices ensure safe operation | |
We use well-known brands of burners and gas valve groups as auxiliary equipment and components, providing a complete gas valve group and accessories including filters, pressure regulating valves, solenoid valves, etc., to ensure the safety of gas. At the same time, it can keep the boiler operating in a combustion state, achieving the dual effects of energy conservation and environmental protection. |
Nine safety protection devices, including automatic flame regulation and detection, high pressure protection, gas valve group and protection system, flue gas overheating protection, power-off protection, motor phase loss and overload protection, and burner limit opening protection, ensure the safe operation of the boiler. |
Performance advantages
Fangkuai fuel oil gas water pipe hot water boiler,Provide heating and domestic water for various enterprises, institutions, and heating companies.
|
Compact D-type layout structure Small footprint, fast installation
|
![]() |
Advanced membrane wall production equipment The qualification rate of automatic welding flaw detection is 100%
|
|
Ladder waste heat recovery improves thermal efficiency and reduces pollutants
|
|
Convenient and fast transportation, installation, and maintenance
|
Multiple protection functions ensure safe and stable operation of the boiler
|
|
![]() |
Chinese large screen control with simple operation
|
For detailed information about Fangkuai Boiler products, please call our customer service hotline or click on the online consultation button on the right
Customer service hotline: 400-100-9030
Technical Parameter
Project model | unit | SZS10.5-1.25/130/70-Y(Q) | SZS14-1.25/130/70-Y(Q) | SZS17.5-1.6/130/70-Y(Q) | SZS21-1.6/130/70-Y(Q) | SZS24.5-1.6/130/70-Y(Q) | SZS29-1.6/130/70-Y(Q) | ||
Rated thermal power | MW | 10.5 | 14 | 17.5 | 21 | 24.5 | 29 | ||
Rated outlet pressure | MPa | 1.25 |
1.25 | 1.6 | 1.6 | 1.6 | 1.6 | ||
Wind turbine power | KW | 37 |
55 | 75 | 90 | 90 | 110 | ||
Fuel | diesel oil | Kg/h | 914.5 | 1245.5 | 1524.4 | 1829.3 | 2134.1 | 2540.7 | |
heavy oil | Kg/h | 950.8 |
1267.7 | 1584.7 | 1901.6 | 2218.6 | 2641.1 | ||
natural gas | Nm^3/h | 1004.8 | 1388.3 | 1674.6 | 2009.6 | 2344.5 | 2791.1 | ||
city gas | Nm^3/h | 2040.8 | 2721.1 | 3401.4 | 4081.6 | 4761.9 | 5668.9 | ||
liquefied petroleum gas | Nm^3/h | 367.4 | 489.8 | 612.3 | 734.8 | 857.2 | 1020.5 | ||
air supplypressure |
natural gas | mmH2O | 2000-3000 | 2000-3000 | 3000-20000 | 3000-20000 | 15000-20000 | 15000-20000 | |
Urban gas | mmH2O | 2000-3000 | 2000-3000 | 3000-20000 | 3000-20000 | 15000-20000 | 15000-20000 | ||
Liquefied petroleum gas | mmH2O | 3000-4000 | 3000-4000 | 5000-20000 | 5000-20000 | 15000-20000 | 15000-20000 | ||
Transport dimensions | long | mm | 8300 | 8416 | 9640 | 10120 |
10360 | 10760 | |
wide | mm | 3385 |
3385 | 3830 | 3800 | 4200 | 4200 | ||
high | mm |
3800 | 4016 | 4070 | 4070 | 4332 | 4332 | ||
Installation size |
long | mm | 10230 | 11100 | 12634 | 12755 | 13300 | 13705 | |
wide | mm | 7645 | 7645 | 6213 | 7740 | 8330 | 8330 | ||
tall | mm |
5000 | 5205 | 5150 | 5300 | 5476 | 5476 | ||
Transport weight |
T | 30 | 31 | 40 | 43 | 47 | 50 | ||
Water inlet | PN | MPa | 1.6 |
2.5 | 2.5 | ||||
DN | mm | 200 | 200 | 200 | 250 | 250 | 250 | ||
outlet | PN | MPa | 1.6 |
2.5 | 2.5 | ||||
DN | mm |
200 | 200 | 200 | 250 | 250 | 250 | ||
Oil supply import | DN | mm | 22 | 22 | 22 | 25 | 25 | 25 | |
Oil supply outlet | DN | mm |
22 | 22 | 22 | 25 | 25 | 25 | |
Gas supply port |
DN | mm |
According to the gas supply pressure |
||||||
Manual sewage outlet | PN | MPa | 1.6 |
2.5 | |||||
DN | mm |
50 |
|||||||
safety valve |
interface | DN | mm | 100 | 125 | 125 | 150 | 150 | 150 |
PN | MPa | 1.6 |
2.5 | ||||||
bleeder | DN | mm | 125 | 150 | 150 | 200 | 200 | 200 | |
Smoke exhaust interface size | mm |
800*500 | 1400*1050 | 1400*1050 | 1400*1050 | 1800*1050 | 2050*1050 | ||
general | supply water temperature | ℃ | 130 | thermal efficiency | % | 95-98 | combustion method | MPa | Micro positive pressure chamber combustion |
Rated inlet water temperature | ℃ | 70 | Use power supply | V/Hz | 380/50 | Combustion regulation method | MPa | Fully automatic proportional adjustment |
The above parameters do not have contractual nature and should be subject to the specific terms of the contract
The fuel consumption is the value after installing the condenser; Fuel calorific value: heavy oil 9860kcal/kg, diesel 10250kcal/kg, natural gas 9140kcal/Nm3, liquefied petroleum gas 24998kcal/Nm3, city gas 4500kcal/Nm3; Due to the continuous improvement of technology, any changes will not be notified; Please request detailed parameters from Fangkuai headquarters.