★ Overview
The FB3351T intelligent pressure transmitter is a high-performance and highly reliable standard pressure transmitter that uses a silicon material sensor combined with a single-chip microcomputer. At the same time, the FB3351T pressure transmitter is based on the fieldbus HART protocol technology, which superimposes high-frequency signals on a 4-20mA DC output for remote communication, making it convenient for users to configure and set up on site.
The FB3351T pressure transmitter adopts a threaded direct installation method, which is easy to install and use. It is suitable for various occasions and media in industrial measurement and is an ideal pressure measuring instrument in the field of industrial automation.
★ Features
Low temperature impact
Good long-term stability
Stainless steel 1Cr18Ni9Ti process connector
Featuring standard, intrinsic safety, and explosion-proof products
★ Technical parameters
|
● Target audience |
Liquid, gas, steam |
|
● Measurement range |
Gauge pressure: 0-10kPa~60MPa, absolute pressure: 0-100kPa~10MPa |
|
● Output |
4~20mADC |
|
● Power supply |
12~30VDC |
|
● Load characteristics |
4-20mADC two-wire load R ≤ 50 (V-12) Ω |
|
● Temperature range |
Environmental temperature -20 ℃~+70 ℃; Standard medium temperature -20 ℃~+80 ℃ |
|
● Shell protection |
IP66 |
|
Explosion proof type |
Explosion proof Exd Ⅱ CT6; The intrinsic safety Exia Ⅱ CT6 should be equipped with an external safety barrier |
※performance metrics
|
● Accuracy |
±0.2% |
|
● Stability |
Better than ± 0.1% FS/year |
|
● Response time |
0.1 seconds |
|
● Temperature impact |
Within the range of -20 ℃ to+70 ℃, the variation is less than ± 0.18%/10 ℃ |
|
● Vibration impact |
When the vibration frequency is 20-200Hz in any direction, the change is less than ± 0.02% FS |
|
● Impact impact |
After a 100G impact in any direction for 11ms, the change is less than ± 0.02% FS |
|
● Load impact |
As long as the terminal voltage of the input transmitter is higher than 12V, there will be no load impact. |
|
● Location impact |
The installation position does not affect the zero point |
※Structural indicators
|
● Structural materials |
Shell: Polyurethane baked paint low copper cast aluminum alloy O-ring sealing structure: Fluororubber |
|
● Process connection |
Standard M20 × 1.5 external thread provided |
|
● Electrical connection |
It can be led out from any outlet as needed, suitable for industrial cables with diameters ranging from φ 8.5 to φ 10.0 as leads for sealing The universal cable connector PG16 or M20 × 1.5 can be used for the lead out joint, and the non lead end should be sealed with an end cap |
★ Selection Table
※Selection Table for FB3351T Pressure Transmitter
|
FB3351T |
Pressure transmitter |
||||||
|
┆ |
code name |
pressure type |
|||||
|
┆ |
G |
Gauge pressure measurement |
|||||
|
┆ |
A |
Absolute pressure measurement (customized according to user agreement) |
|||||
|
┆ |
┆ |
code name |
Measurement range (please specify the factory range when ordering; if not specified, the highest rated range shall be used for factory delivery) |
||||
|
┆ |
┆ |
04 |
0~7kPa~20kPa |
||||
|
┆ |
┆ |
05 |
0~10kPa~35kPa |
||||
|
┆ |
┆ |
06 |
0~20kPa~70kPa |
||||
|
┆ |
┆ |
07 |
0~35kPa~100kPa |
||||
|
┆ |
┆ |
08 |
0~70kPa~200kPa |
||||
|
┆ |
┆ |
09 |
0~100kPa~350kPa |
||||
|
┆ |
┆ |
10 |
0~200kPa~700kPa |
||||
|
┆ |
┆ |
11 |
0~350kPa~1.0MPa |
||||
|
┆ |
┆ |
12 |
0~700kPa~2.0MPa |
||||
|
┆ |
┆ |
13 |
0~1.0MPa~3.5MPa |
||||
|
┆ |
┆ |
14 |
0~2.0MPa~7.0MPa |
||||
|
┆ |
┆ |
15 |
0~3.5MPa~10MPa |
||||
|
┆ |
┆ |
16 |
0~7.0MPa~20MPa |
||||
|
┆ |
┆ |
17 |
0~10MPa~35MPa |
||||
|
┆ |
┆ |
18 |
0~20MPa~60MPa |
||||
|
┆ |
┆ |
┆ |
code name |
output signal |
|||
|
┆ |
┆ |
┆ |
E |
4~20mADC |
|||
|
┆ |
┆ |
┆ |
S |
Intelligent 4-20mADC two-wire system+fieldbus HART protocol |
|||
|
┆ |
┆ |
┆ |
9 |
Special requirements |
|||
|
┆ |
┆ |
┆ |
┆ |
code name |
process connection |
||
|
┆ |
┆ |
┆ |
┆ |
R |
Standard M20 × 1.5 external thread |
||
|
┆ |
┆ |
┆ |
┆ |
T1 |
G1/2A external thread |
||
|
┆ |
┆ |
┆ |
┆ |
O |
Process according to the size provided by the user |
||
|
┆ |
┆ |
┆ |
┆ |
┆ |
code name |
option |
|
|
┆ |
┆ |
┆ |
┆ |
┆ |
d |
Explosion proof ExdII CT6 |
|
|
┆ |
┆ |
┆ |
┆ |
┆ |
i |
Intrinsic safety ExiaICT6 |
|
|
┆ |
┆ |
┆ |
┆ |
┆ |
M3 |
3 1/2LCD digital display header |
|
|
┆ |
┆ |
┆ |
┆ |
┆ |
S |
Radiators and process connectors |
|
|
┆ |
┆ |
┆ |
┆ |
┆ |
Y |
User agreement |
|
|
FB3351T G 05(0~30kPa) S |
R |
i |
|
Example of transmitter selection |
|||