Product Features
The EX2-ZL DC power monitoring instrument is a new generation of panel mounted miniature energy meters developed by Shandong Lichuang Technology Co., Ltd. based on years of experience in energy metering product design. This energy meter adopts LCD display, which can display voltage, current, power, forward energy, reverse energy, communication address, communication verification method, communication baud rate, voltage conversion ratio, current conversion ratio and other parameters, and has the function of outputting electrical energy photoelectric pulses; RS485 communication interface can be used to exchange data with the upper computer, supporting MODBUS-RTU protocol, which greatly facilitates power automation management.
This electric energy meter has the advantages of small size, easy installation, high accuracy, and good EMC performance.
PRODUCT FUNCTION
Measure forward and reverse electrical energy
Measure voltage, current, and power
After power failure, all stored data will not be lost and can be maintained for more than 10 years
7-bit wide temperature LCD display
◆ Can achieve data loop display, with a loop display time of 2 seconds
◆ Equipped with an electrical pulse output interface and a red LED indicator
The button can be used to set the verification method, baud rate, voltage ratio, and current ratio
Communication interface: RS485 (optical isolation)
Communication protocol: MODBUS-RTU
Communication speed: 1200bps, 2400bps, 4800bps, 9600bps can be set.
PRODUCT FUNCTION
performance |
parameter |
||
Losing enter measure measure apparent show |
electricity press |
measuring range |
Directly connect to -48V (± 10%), and when measuring a larger range, a voltage divider device can be used and the voltage transformation ratio can be changed. The maximum range of indirect intervention is 500V |
transformation ratio |
1-500,Uo×Ubb<500V |
||
accuracy |
RMS measurement (voltage accuracy:0.5Grade) |
||
electricity flow |
range |
Indirect access 0-75mV, corresponding to 0-1A, the range can be expanded by changing the current ratio, indirectly connecting to a maximum measurement of 1000A |
|
transformation ratio |
1-1000,Io×Ibb<1000A |
||
accuracy |
RMS measurement (current accuracy:0.5Grade) |
||
forward power |
Active accuracy: Level 1; Maximum measurement up to 500kW |
||
reverse power |
Used to indicate the wiring direction of the splitter. If the splitter is connected in reverse, the module will display the reverse power |
||
Electricity Can Testing Quantity |
Positive electrical energy |
Accuracy: Level 1. When (Uo × Io × Ubb × Ibb)>=2515, the maximum measurement reaches 999999 kWh and then resets to zero; When<2515, the maximum measured kWh is (397.682 × Uo × Io × Ubb × Ibb), and it automatically resets to zero when the maximum value is reached. |
|
Reverse electrical energy |
Used to indicate the wiring direction of the splitter, the splitter is connected in reverse, and the module accumulates reverse electrical energy |
||
electricity source |
power supply |
Internal power supply |
|
power consumption |
<3W |
||
transport go out approve weave Cheng |
open up or clear out by poking or jabbing interrogate
|
output interface |
RS-485 interface, two-wire system+ 15kV ESD protection |
Communication Protocol |
Standard MODBUS-RTU communication protocol |
||
data format |
Can be set; 10 bits, 1 start bit 0, 8 data bits, 1 stop bit 1; Or 11 bits, which can be set by software for odd, even, or no verification; |
||
COMMUNICATION RATE |
BPS: 1200, 2400, 4800, 9600 can be set |
||
display |
LCD segment code display |
||
Electric pulse output |
Optical signal output |
||
ring area |
work environment |
Working temperature:-15~50℃ |
|
storage environment |
Storage temperature:-20~60℃ |
||
relative humidity |
Relative humidity ≤ 90%No condensation |
||
peaceful complete |
pressure resistance |
Input and output>1kV |
|
isolation |
Output, input, and power supply to casing>5M |