High quality suppliers of instruments in China's electronics industry - JETYOO Industrial&JETYOO InstrumentsSpecializing in providing services for users in ChinaESPEC ARL-0680-AE High and Low Temperature Test ChamberProduct SeriesInstrument and equipment, technical training, and after-sales maintenance services, Support、 Sales Sale and Service, 3S Company, is a technology oriented instrument comprehensive service provider in the East China region of Shanghai. We are your trusted instrument expert in the electronics industry.
ESPEC ARL-0680-AE High and Low Temperature Test ChamberProduct SeriesApplicable standards: GB/T2423.3 / IEC60068-2-78、GB/T2423.4 / IEC60068-2-30、GB/T2423.34 / IEC60068-2-38、GB/T2423.22 / IEC60068-2-14、JESD22-A100-C、JESD22-A101-C。
Product Specification for Series Products
1. Model
2. Test box capacity
3. Power supply voltage variation: ± 10% of rated value
4. Maximum load current
5. Balanced temperature and humidity control method (BTHC method)
6. Operating conditions: Environmental temperature: 0~+40 ℃
Environmental humidity: maximum 75% RH (below dew point at 30 ℃ and 75% RH)
7. The performance temperature chamber shall comply with IEC 60068-3-5:2001 JTM K07: 2007 is the standard, and the humidity chamber follows IEC 60068-3-6:2001
JTM K09: 2009 is the standard. Depending on the surrounding environmental conditions, there may be situations where the specifications and performance cannot be met.
The performance under rated voltage and without samples at an ambient temperature of+20 ℃.
7.1 Temperature performance
ARL-0680-AE ,ARL-1100-AE
Temperature range -45 to+180 ℃ -45 to+180 ℃
Temperature fluctuation ± 0.3K ± 0.3K
Temperature slope 3.0K 3.0K
Test box capacity 680L 1100L
AC380V
3φ 4W
50Hz (CE specification * 1)
AC400V
3φ 4W
50Hz (CE specification * 1)
0680 23A 22A
1100 25A 23A
*1. CE marking in accordance with the European Union (EU) directives. The following are referred to as CE specifications.
7.1.4 Space temperature deviation
3.0K 3.0K
7.1.5 Temperature change rate
Excluding the top and bottom 10% between high and low temperatures, and the temperature change rate within the temperature range.
Rising speed (average) -22.5 ℃ →+157.5 ℃
6.3K/minute 4.7K/minute
Descent rate (average)+157.5 ℃ → -22.5 ℃
4.8K/minute 4.4K/minute
Descent rate (average) at ambient temperature+25 ℃
4.1K/minute 4.1K/minute
According to the changes in ambient temperature, the rate of temperature change (decrease) varies as shown in the following figure.
ARL-0680
ARL-1100
Temperature change rate [K/min]
Environmental temperature [℃]
Temperature decay rate [K/min]
Environmental temperature [℃]
7.1.6 Time for reaching extreme temperature
The arrival time of high/low temperature
Rise time+20 ℃ →+180 ℃
Within 30 minutes and 40 minutes
Descent time+20 ℃ → -45 ℃
Within 50 minutes
When the descent time is+20 ℃ → -45 ℃ and the ambient temperature is+25 ℃
Within 62 minutes
According to the variation of environmental temperature, the time for reaching the extreme temperature (decrease) changes as shown in the following figure.
7.1.7 Allowable heating load
Temperature inside the box:+20 ℃
4500W 4500W
7.2 Temperature and humidity performance
7.2.1 Temperature Range
10~95℃ 10~95℃
7.2.2 Humidity Range
10~98%rh 10~98%rh
Environmental temperature [℃]
Time to reach extreme temperature [minutes]
Note: When the temperature inside the box is below 40 ℃, the cooler (also serving as a dehumidifier) will frost and continuous operation will be limited.
7.2.3 Humidity fluctuations
±2.5%rh ±2.5%rh
7.2.4 Humidity Slope
10%rh 10%rh
7.2.5 Spatial humidity deviation
10%rh 10%rh
7.2.6 Allowable heating load
Temperature and humidity inside the box:+ At 85 ℃ and 85% RH
500W 500W
7.3 Noise
The measurement of noise is carried out indoors without sound, and the value is measured at a height of 1.2m and 1m from the front of the test box (JIS-Z-8731:1999 A standard)
Sex). Due to the influence of the installation environment, surrounding noises may increase the noise level, so attention should be paid to the installation environment.
61dB 62dB
8 Structure
8.1 Composition Materials
8.1.1 Shell stainless steel plate (SUS430 CP, surface brushed treatment)
8.1.2 Inner box stainless steel plate (SUS304 CP, # 400 surface treatment)
8.1.3 Insulating material glass wool+phenolic foam
8.2 Laboratory temperature and humidity control room+test chamber
8.2.1 Temperature and humidity control room air guide plate, air supply fan, heater, cooler (also dehumidifier), humidifier, air burning prevention device
Humidifier supply and discharge ports, suction grille
8.2.2 Test box dry bulb temperature detection terminal, wet bulb temperature detection terminal, gauze disc, cable hole
Test box drainage outlet, cover for drainage outlet, top panel
shelf bracket
The maximum load-bearing capacity of the ground (the sum of the load-bearing capacity of the bracket and the load-bearing capacity of the ground in the test box)
0680 80 ㎏
(including shelf weight)
80 ㎏
(Uniform distribution) 80kg
1100 100 ㎏
(including shelf weight)
150 ㎏
(Uniform distribution) 150kg
8.3 Door handle (right handle, left hinge, with key), one door, door lock release device, box door water pan
Temperature and humidity program indicator regulator (color LCD display, set through touch screen)
Operation switch, temperature rise prevention device
8.4 Control panel main power switch (load switch or leakage switch), sample power control terminal
Time signal terminal, communication port, sample temperature input terminal
8.5 Pump for humidifying water in the water circuit room, pump for supplying wet ball gauze, pump for humidifying drainage
Mechanical room exhaust hole (top)
8.6 Mechanical room compressor unit, compressor exposed tray, condenser fan, condensate tray, drainage pipe
Mechanical room exhaust hole (rear), water supply tank, condenser filter
8.7 Choose either the top or back of the power cord insertion hole
8.8 Back of drainage pipe (3 pieces)
8.9 One water supply (direct connection) port on the back
9. Size and weight
9.1 Dimensions
Internal dimensions 850 × 1000 × 800 1100 × 1000 × 1000
External dimensions 1050 × 1955 × 1955 × 2005
Excluding protruding parts (W × H × D mm)
9.2 Weight
510 ㎏ 600 ㎏
10. Nickel chromium alloy electric heating wire heater: 6kW (3kW x 2 pieces)
11 humidifier SUS316 armored heater (surface evaporation type)
4kW (2kW x 2) 5kW (2.5kW x 2)
12 cooler plate fin cooler (also dehumidifier) 1 unit
13 Freezing Methods Mechanical single-stage compression freezing method
13.1 Compressor Vortex Compressor
13.2 Condenser Air cooled Condenser
13.3 Expansion Mechanism Electronic Automatic Expansion Valve
13.4 Compressor Capacity
3.0kW 3.75kW
13.5 Refrigerant R404A
14. Calculation and installation
Name: N Installation P-310
Composition of user interface, host I/O
Display function
Equipped with touch screen
7.0-inch color LCD
Backlight LED (with a lifespan of 50000 hours)
Driving method TFT
Display pixels 800x480 (WVGA)
Status display LED external storage indicator light, communication indicator light, scheduled reservation indicator light
Power indicator light
Hardware switch with power indicator light (button type)
Control Function Temperature and Humidity Control Function
control mode
PID control (corresponding to sample temperature control)
Temperature input
Test chamber temperature (JIS T-type thermocouple)
Sample temperature control (JIS T-type thermocouple)
Humidity input
Test box dry wet bulb temperature input method (JIS T thermocouple)
Input function
100ms high-speed sampling function, wire breakage detection function
Adjust function
Temperature deviation setting function
Adjustment range ± 5.0 ℃
Set the minimum resolution to 1 decimal place
Running mode: Fixed value running, program running, remote running, stop
Run settings
Fixed value setting
Can be set to 3 modes
Set range and resolution
Temperature -50.0 ℃ to+185.0 ℃, measured in 0.1 ℃ units
Humidity range from 0% RH to 100% RH, measured in units of 1% RH
Set Function
Sample temperature control setting, humidity control OFF setting, compressor setting, time signal
Setting, upper and lower limit absolute alarm setting, upper limit deviation alarm setting, fixed value mode name
setting
programming
Can set up 40 modes (with up to 99 steps per mode)
Set range and resolution
Temperature -50.0 ℃ to+185.0 ℃, measured in 0.1 ℃ units
Humidity range from 0% RH to 100% RH, measured in units of 1% RH
Time 0 hours 1 minute to 9999 hours 59 minutes, measured in 1 minute units
Setting function (in addition to the setting function of fixed values, it also includes the following setting functions)
Temperature slope setting, humidity slope setting, exposure time setting, pause setting, start
Condition setting, end condition setting (program can be linked), count setting (A, B), program
Name setting, program list display
Languages: Japanese, English, Chinese (simplified and traditional characters), Korean
(No need to restart, switch through screen settings)
Name: N Installation P-310
Auxiliary functions
standard function
basic function
Operation function, alarm function, information function, accessory function (time accumulator, drainage setting), help function, box monitoring function (temperature and humidity, external output, trend chart), traceability function
Management setting function
Timer setting (start timing, end timing, fast timing), sampling setting, protection setting, alarm history display, version information, periodic inspection and maintenance list display, notification function, timer with reset function, add on/system update history display
Maintain the setting function
Communication settings (LAN settings), device operation action settings (power outage reset action settings, backup operation settings, door opening action settings), setting criteria for determining arrival, time signal name settings, screen settings, sound settings, date settings? Screen settings, user password
Code login, deviation adjustment, detailed device settings (power frequency, continuous supply of gauze), sample temperature control environment settings
Select communication function (RS485, RS232C, GPIB), recorder setting function (output item setting), external alarm output setting function, humidification delay function
External storage function
interface
USB 2.0 standard
(Type A socket)
500mA (largest)
Corresponding device USB large capacity flash card
Corresponding file formats FAT16/FAT32
Corresponding functions
Sampling and Writing Settings
Program mode writing/reading
Traceable data writing
Add on/System Update
Corresponding to PC application mode Manager Lite
The Mode Manager Lite can be downloaded exclusively for Test Navi product members.
Network function
interface
Ethernet interface
(100baseTX)
Communication Protocol TCP/IP (HTTP, SMTP, IPv4)
WEB application
Monitoring function, setting function, operation function
Data collection function and management settings? Maintain the setting function
E-Mail Notification
Corresponding browser
Windows Internet Explorer10
PC communication function Ethernet interface and PC1-to-1 connection
Action environment
Performance guarantee: ambient temperature+23 ℃± 5 ℃, humidity 30% RH~90% RH (no condensation)
Ensure that the ambient temperature is between 0 ℃ and+60 ℃, and the humidity is between 30% RH and 90% RH (without condensation)
Storage environment temperature -20 ℃~+70 ℃, humidity 20% RH~95% RH (no condensation)
Display Accuracy
Temperature (T-type thermocouple)
(When the ambient temperature is+23 ℃± 1 ℃)
Measurement accuracy ± 0.3 ℃
Display accuracy (full range) ± (0.07% FS+1 digit)
Time difference within 60 seconds+23.0 ℃± 5 ℃
9 Aspec Corporation
15. Main power switch
Load switch (AC380V/AC400V)
Used for turning on/off the main power supply
(1) Rated voltage AC380V/AC400V 3 φ N/PE 50Hz
The main power supply is not equipped with a circuit breaker.
A circuit breaker (32A SLOW) must be installed.
(2) Rated current 32A
16. Multi blade fan for circulating inside the box
16.1 Drive mode: Direct connection mode of electric motor
16.2 Two 100W electric motors
17. Low noise pressure ventilation fan for condenser
100W 2 pieces
18. Equipment
18.1 One cable hole with a diameter of 100mm on the right side
One left side with a diameter of 100mm
18.2 Caster Free Caster 4
18.3 Adjust 4 feet
18.4 Time signal terminal
Test status report * Contact capacity AC250V 1A 2-point
18.5 Sample power control terminal
Test protection contact capacity AC250V 3A 1
18.6 Sample temperature input terminal 1
18.7 The power cord is not included.
19. Attachment
19.1 Cable hole rubber plug, 2 pieces of 100mm silicone sponge rubber
19.2 Bracket
19.2.1 Shelving strip stainless steel plate (SUS304 CP) 1 set
19.2.2 Shelf Stainless Steel Wire (SUS304) 1 piece
Outer dimensions, shelf weight, shelf load-bearing capacity
(Uniform distribution)
0680 817×27×750 6 ㎏ 40 ㎏
×28×950 12 ㎏ 50 ㎏
(W×H×D ㎜)
Number 4412001007021
19.3 Glass tube fuse B type 250V 0.4A, 5A, 8A 1 each
19.4 Wet ball gauze, 24 sheets, 1 straw, 1 box
19.5 Thermocouple for sample temperature measurement
T-type thermocouple (3m) (IEC 60584-1:1995) 1 piece
19.6 Sample temperature input interface 1
19.7 User Operation Manual CD, 1 set of Setting Guidelines
19.8 Use 2 key doors
20. Safety features
Functional purpose Action content
1 Control circuit 1 Overcurrent protection device a
2 System abnormality protection device b
3 Reversion prevention relay protection equipment b
4 Temperature fuse protection equipment b
5. Temperature switch protection equipment for air supply fan b
6. Short circuit protection for air supply fan, glass tube fuse protection equipment b
7. Temperature Overrise Protector for Sample B
8 room temperature compensation disconnection detection circuit protection device b
9. Dry bulb temperature disconnection detection circuit protection device B
10 sample temperature disconnection detection circuit (only in sample temperature control) protection device B
11 Condenser fan short circuit protection device B
12 Condenser fan overload protection device B
13 Compressor 1 Temperature sensor disconnection detection circuit protection equipment b
14 Compressor 1 Short Circuit Protection Equipment b
15 Compressor 1 Overcurrent protection device b
16 Compressor 1 Discharge Pipe Temperature Switch Protection Equipment B
17 Compressor 1 High and Low Pressure Switch Protection Equipment B
18 compressor 1 frost detection circuit protection equipment b
19 Compressor 1 circuit temperature range outside protection equipment b
20 heaters? Humidifier overcurrent protection device b
21 control circuit 2 overcurrent protection device b
22 Control circuit short circuit protection glass tube fuse protection equipment b
23 Temperature upper and lower limit absolute alarm function (built-in in temperature and humidity regulator) to protect sample b
24 Wet bulb temperature disconnection detection circuit protection device c
25 humidifier air burning prevention device protection equipment c
26 humidifier water level detection and protection equipment c
27 Temperature upper limit deviation alarm function (built-in in temperature and humidity regulator) to protect sample d
28 humidity upper and lower limit absolute alarm function (built-in in temperature and humidity regulator) to protect sample d
29 Water supply tank water shortage switch protection equipment e
30 door switch protection personnel f
Functional purpose Action content
31 Gauze drying detection and protection equipment g
32 Water supply tank low water level switch protection equipment g
33 sample power control terminal protection sample h
a : The entire device stops.
b : Display an alarm and the alarm buzzer will sound. The device stops running.
c : Display an alarm and the alarm buzzer will sound.
When the backup is turned off, the device stops running.
When the backup operation is turned on, the device continues to run at temperature.
d : Display an alarm and the alarm buzzer will sound. The device performs the designated safety actions.
e : Display an alarm and the alarm buzzer will sound. The device continues to operate at high temperature.
f : Display an alarm and the alarm buzzer will sound.
When the pause action is OFF, the device continues to operate.
When the pause action is turned on, the device pauses operation.
The alarm display and alarm buzzer can be turned on/off.
g : Display an alarm and the alarm buzzer will sound. The device continues to operate.
h : When the equipment stops running or the safety device stops running, the power supply to the sample is stopped.
21. Water supply
21.1 Water supply method Water supply pump
21.2 Installation position of water tank
Front of the mechanical room
21.3 Water tank capacity 40L (fixed water tank 20L x 2)
21.4 Automatic water supply port diameter: Rc3/8 (rear)
21.5 Water conductivity: 0.1-10 μ S/cm
Pure water at 6-7 pH
21.6 Water supply pressure 0.01MPa~0.05MPa
22. Limitations of the sample: The following substances are not allowed to be used for testing.
Explosive substances, flammable substances, and substances containing such substances
Substances with corrosiveness
biology
Substances that exceed the allowable heating load
23. Excluded Projects
Moving in? Preparation project for installation site
A power engineering project
Water supply and drainage engineering
Series product technical specifications, parameters, and indicators
ESPEC High and Low Temperature Damp Heat Test Chamber ARL-0680-AE, ARL-1100-AE Model ARL−0680 ARL−1100 Model ARS−0220 ARS−0390 ARS−0680 ARS−1100 Model ARU−0680 ARU−1100 Model ARG−0220 ARG−0390 ARG−0680 ARG−1100 (ARS-0680/1100, ARG-0680/1100)
AR series has big allowable heat loads generated by the specimen,
and achieves improved temperature change rate in an expanded temperature and humidity range.
The new N-instrumentation allows AR series chambers to support easy-to-use networking system.
ESPEC offers two temperature control ranges: −75℃ to +180℃ or −45℃ to +180℃ ,
with or without humidity control (10 to 98%rh).
These models incorporate the most desirable features in temperature and humidity chambers.
ARS−0220
*Viewing window is optional.
ARS−1100
Advanced reliability
Environmental Stress Chambers
1
2
Superior temperature heating
and cooling control
at 3℃ /min. with specimen load
Temperat ure heating and cooling
performance at 4 to 6℃ /min. (no load),
and can handle temperature cycle tests at
3℃ /min. (with load*)
* ARS-1100 specimen: aluminum 38kg
(including shelf 12kg)
Highly uniform temperature
distribution
Highly uniform temperature distribution
minimizes variations in test results.
Reduced temperature and
humidity stabilization time
Temperature and humidity stabilization
time is greatly reduced by minimizing
hunting as the chamber approaches setpoint. (under testing operation from RT
to 85℃ /85% rh).
Wider control range for
temperature and humidity
Features a wider control range of
temperature and humidity, including
stable control at 95℃ /98% rh.
Meets international standards
D e sig ne d t o c omply w it h m ajor
environmental test standards such as
IEC60068-2, or ISO16750-4 (5.3).
(Refer to compatible test standards)
International safety standard
compliance
Complies with Safety of Machinery
(ISO 12100), Low Voltage (IEC 60204),
EMC (IEC 61000-6-2, IEC 61000-6-4).
Temperature (℃)
100
90
98
80
70
60
50
40
30
20
10
10 20 30 40 50 60 70 80
95
90 100
0
Relative
Humidity
(%rh)
ARS? ARL
PR?PL? PSL
*Continuous operation at or below +40℃ is limited because of frost formation on the cooler
and dehumidifier.
Temperature & Humidity Control Range
(ambient temperature at +20℃ with no load)
Characteristics
● Compatible Test Standards
?IEC60068-2-1: Cold
?IEC60068-2-2: Dry heat
?IEC60068-2-3: Damp heat, steady state
?IEC60068-2-14 Nb: Change of temperature with
specified rate of change *
?IEC60068-2-38: Composite temperature/ humidity
cyclic test *
?IEC60068-2-78: Damp heat, steady state
?ISO16750-4 5.3: Temperature cycling
Model Heat up (K/min.) Pull down (K/min.)
ARL/ARU−0680 6.3 4.8
ARL/ARU−1100 4.7 4.4
ARS/ARG−0220 6.0 5.2
ARS/ARG−0390 5.0 4.0
ARS/ARG−0680 6.0 4.2
ARS/ARG−1100 4.7 4.1
Temperature change rate
*At ambient temperature, + 20℃ no specimen.
Safety precautions
● Do not use specimens which are explosive or flammable, or which
contain such substances.
Supports heat loads
up to 4500W*
(During temperature testing)
Supports electrically-charged specimens,
and can compensate up to 4500W of
heat load during temperature testing,
depending on the chamber model (500W
during temperature and humidity
testing).
* Test area temperature:+ 20℃
User-friendly features
Standard features include cable ports on
both sides which allow free access of
the test area. Antirust and oil proof 18-8
Cr-Ni stainless steel plate is used as
external panels. It is possible to select
water supply via water tank or direct
water coupling alliteratively all the
time.
Chamber restricted to
lock the door
It is now possible to lock the chamber
door to prevent accidental operation of
the chamber during testing.
The handle part design has also been
improved so the door closing is easier
and safer.
New refrigeration circuit and
condenser filter improves
reliability
Thanks to newly designed refrigeration
circuit, reliability is improved. And
further more condenser filter, prevents a
condenser fan from clogging becomes
standard equipment.
Cable ports on both walls
Water tank Key
Characteristics
4
Controller N-instrumentation
N-instrumentation equipped
with a color LCD touch panel
Wide 7-inch screen with LED backlight
is clearer and provides faster display
speed.
Interior light button
It is able to switch ON/OFF from the
interior light button any time.
Information button
When there are some things need to be
notified to the operator, information
button will alart to the operator. By
pressing the button, you will find
notifications such as 'Check Humidity
Tray'.
Trend graph output on
USB memory
Trend graphs can be displayed on the
web application or downloaded on USB
m e m o r y. I t i s a l s o p o s s i b l e t o
continuously register data on USB
memory if numerous data records are
needed.
N-instrumentation
USB memory port
Touch icon to show
navigation bar.
Touch navigation
Interior light
Display TFT Color LCD (7.0inch)
Operating mode Constant operation, Program operation, Remote operation, Stop
Setting range
● Constant setup: 3 patterns
Setting range: Temp.: −80.0℃ to +185.0℃ , 0.1℃ unit (ARS, ARG)
Temp.: −50.0℃ to +185.0℃ , 0.1℃ unit (ARL, ARU)
Humidity: 0 to 100% rh, 1% unit (ARS, ARL)
● Program setup: 40 patterns (99 steps)
Setting range: Temp.: −80.0℃ to +185.0℃ , 0.1℃ unit (ARS, ARG)
−50.0℃ to +185.0℃ , 0.1℃ unit (ARL, ARU)
Humidity: 0 to 100% rh, 1% unit
Time: 0 hour and 1 min. to
9999 hours and 59 min. 1 min. unit
Language Japanese, English, Chinese (simplified, traditional), Korean
Interface USB 2.0 standard compliant (A-type connector)
External memory
function
Write sampling data, Read/ Write program, Backtrace output,
Add-on/system updates
Network function Interface: Ethernet port (100base-TX)
Web function Monitoring, setting, operation, Data Record Function,
maintenance setting, alert
Browser Windows Internet Explorer10
Application of USB MEMORY
Continous record test data
Data transfer
Copy test program
5
Network
Remote monitoring and control
(Ethernet connection)
A unique web application allows the
user to monitor the chamber, set
programs, and start and stop operation
from a PC connected to the chamber
Ethernet port (LAN’s port). No software
required, the chamber can be accessed
and controlled from PC via a web
browser (Smartphone, tablets and the
like can also be used).
Wireless connection and multiple units
connection are also possible.
alert
When an alarm is triggered, an is
sent to the registered PC or
address. A notification can also be sent
at the time of test completion.
*Requires an intranet environment capable of
sending s.
Multilingual display
The language available for the Web
application (Japanese/ English/ Simplified
Chinese/ Traditional Chinese/ Korean)
can be changed without affecting the
N-instrumentation language display.
Remote monitoring and control thanks to a Web application
Ethernet
Example of Wireless LAN Connection
Example of Connection within the Interior
Program copy and computer editing
Carrying the line
スマートフォン
タブレットコントローラー
(オプション)
PC
Edit
Copy
Small environmental tester
(Equipped with Wi Fi function)
Wi-Fiルーター
(オプション)
スマートフォン
スマートフォン
Small environmental tester
Small environmental tester
ワイヤレスダイレクト
(オプション)
Program copy and computer editing
Edit
Copy
AR series
Ethernet
Network
Wi-Fi router
Smartphone Tablet controller
PC
Ethernet
phone
Smartphone
Mail server
Intranet
(company LAN)
alert
PC
AR series
Environmental
Stress Chamber
● Program editing ● Graph display
Image
Screen
Privileges Chamber monitor Constant Mode/ Program Setup Run/ Stop configuration Device
Administrator ○ ○ ○ ○
Operator ○ ○ ○ ×
User ○ × × ×
Login information
○= available; ×= Not available
6
Network
エスプクイトーワーク Search
Search for エスプスクオンライン
Test Building
Centralized Management System (formerly: Web Integrated Management System) (alternative)
Confirm the status of 100 testers on one screen
It is possible to connect with a centralized management system.
Ethernet
Ha イパワー Constant Temperature (Humidity) Device
ネットワークアダプター
Old: RS-485
LANコンバーター
Ethernet
プラチナスKシリーズ
Office Building
Ethernet
Ethernet
Centralized management system
クライアントPC
イントラネット
Scheduled for March 2015
Lab
Web Integrated Network (Sold separay)
Maximum 100units of connected chambers and other peripherals necessary
for environmental testing are manned via Internet.
Ethernet
AR series
LAN converter
Ethernet
Platinous K Series
Office
Ethernet
Ethernet
Web integrated
network system
Client PC
Intranet
Access to video
Copy and reproduce testing
Thanks to the USB memory you can
copy the same test program in multiple
chambers, provided that they have the
same operation range. No need to
program each chamber, just connect the
USB and the test can start.
Download edit programs online
Via the Pattern Manager Lite software
installed on your PC, edit programs
according to your testing needs, and
upload them with a USB.
Edit programs
Through our online website Test Navi,
dedicated to reliability and testing
information, you can find most of the
recognized international standard,
available for download.
Charge them as is on your USB memory,
or edit them and transfer to your chamber.
* Test Navi is a website dedicated to reliability
testing information and technologies. http://
www.test-navi。。 com/eng/index.html
The Pattern Manager Lite software allows
you to edit programs for your chamber,
view and edit data as graph, etc.
The software can be downloaded from the
Test Navi website.
Product Membership App
Information from ターンルージャー
WEB Information Development
Environmental testing specification one
パターンマーネージャーLite
Trial Conditions Summary グラーンタンウンラータンウンラーターンタンタンウンラータンタンタン
ダウンロード
Test Specifications Brochure パターン
Methods of using Febrile
Here are some useful methods. ムービー
Product registration
membership Website
Download Pattern Manager and
WEB Manager information.
Environmental Test
Standards
For Pattern Manager Lite
Test methods download
Download
Product Registration
Membership Website
Product Membership App
Information from ターンルージャー
WEB Information Development
Environmental testing specification one
パターンマーネージャーLite
Trial Conditions Summary グラーンタンウンラータンウンラーターンタンタンウンラータンタンタン
ダウンロード
Test Specifications Brochure パターン
Methods of using Febrile
Here are some useful methods. ムービー
Product registration
membership Website
Download Pattern Manager and
WEB Manager information.
Environmental Test
Standards
For Pattern Manager Lite
Test methods download
Download
Product Registration
Membership Website
● Test Navi
( http://www.test-navi .. com/eng/index.html)
This website provides practical knowledge on environmental testing
that ESPEC has acquired through years of experience, as well as
covering everything from the fundamentals to the latest information on
environmental and reliability testing.
? Updates for chamber controller software
? Search for environmental test standards
? Download test profiles from a list of environmental test standards
Ethernet
Example of Wireless LAN Connection
Example of Connection within the Interior
Program copy and computer editing
Carrying the line
スマートフォン
タブレットコントローラー
(オプション)
PC
Edit
Copy
Small environmental tester
(Equipped with Wi Fi function)
Wi-Fiルーター
(オプション)
スマートフォン
スマートフォン
Small environmental tester
Small environmental tester
ワイヤレスダイレクト
(オプション)
Program copy and computer editing
Edit
Copy
AR series
Ethernet
Network
Wi-Fi router
Smartphone Tablet controller
PC
Ethernet
phone
Smartphone
Mail server
Intranet
(company LAN)
alert
PC
AR series
Environmental
Stress Chamber
7
TEMPERATURE & HUMIDITY CHAMBER
ARL −45 to +180℃? 10 to 98%rh
ESPEC High and Low Temperature Damp Heat Test Chamber Model ARL-0680 ARL-1100
System Balanced Temperature & Humidity Control (BTHC) system
Temp. performance *1
Temp. range −45 to +180℃ (−49 to +356℉ )
Temp. fluctuation ±0.3K
Temp. variation in space 3.0K
Temp. rate
of change *2
Heat up rate 6.3 K/min. 4.7 K/min.
Pull down rate 4.8 K/min. 4.4 K/min.
Max. allowable heat load 4500 W Test area temperature: +20℃
Temp. & humid.
performance *1
Temp. & humid. range +10 to +95℃ / 10 to 98%rh
Humid. fluctuation ±2.5%rh
Max. allowable heat load 500 W Test area conditions: +85℃ /85%rh
Construction
Exterior material 18 Cr-stainless steel plate (Hairline finish)
Test area material 18-8 Cr-Ni Stainless steel plate (BA finish)
Insulation Foamed phenol, glass wool
Heater Nichrome strip wire heater (3 kW×2)
Humidifier Sheathed heater
Cooler Plate fin cooler and dehumidifier
Refrigeration unit
System Mechanical single-stage refrigeration system
Refrigerator Scroll-type compressor
Refrigerator capacity 3.0 kw 3.75 kw
Expansion mechanism Electronic expansion valve
Refrigerant R404A
Air circulator Sirocco fan
Interface Ethernet
Fittings 100mm cable port (×2), specimen power supply control terminal, condenser filter,
specimen temperature input terminal, time signal (×2), casters with levelling feet (×4)
Capacity 680 L 1100 L
Chamber total load resistance 80 kg 150 kg
Inside dimensions mm (inch) *3 W850×H1000×D800 (W33.5×H39.4×D31.5) W1100×H1000×D1000 (W43.3×H39.4×D39.4)
Outside dimensions mm (inch) *3 W1050×H1955×D1805 (W41.3×H77.0×D71.1) W1300×H1955×D2005 (W51.2×H77.0×D78.9)
Weight 510 kg 600 kg
Utility requirements
Allowable ambient conditions 0 to +40℃ (+32 to +104℉ ) / 75%rh max.
Power
supply *4
200V AC 3φ50/60Hz 53 A 56 A
220V AC 3φ60Hz 49 A 52 A
380V AC 3φ50Hz 23 A 25 A
400V AC 3φ50Hz *5 22 A 23 A
Noise level *6 61 dB 62 dB
Exhaust heat quantity kJ/h (kcal/h) 32400 (7743) 39600 (9464)
*1: At ambient temperature +20℃ , no specimen. Performance shown above conforms to IEC 60068-3-5:2001 and IEC 60068-3-6:2001.
*2: Temperature rate of change in the temperature range excluding ±10% of max/min. temperature.
*3: Excluding protrusions.
*4: Power supply voltage fluctuation to be ±10% of rated value.
*5: Conforms to CE marking based on EU directives.
*6: Measurements are to be taken in an anechoic room at a height of 1.2m from the floor and a distance of 1m from the chamber front panel
(ISO 1996-1:2003 _ A-weighted sound pressure level).
8
TEMPERATURE & HUMIDITY CHAMBER
ARS −75 to +180℃? 10 to 98%rh
ESPEC High and Low Temperature Damp Heat Test Chamber Model ARS-0220 ARS-0390 ARS-0680 ARS-1100
System Balanced Temperature & Humidity Control (BTHC) system
Temp. performance *1
Temp. range −75 to +180℃ (−103 to +356℉ )
Temp. fluctuation ±0.3K
Temp. variation in space 3.0K
Temp. rate
of change *2
Heat up rate 6.0 K/min. 5.0 K/min. 6.0 K/min. 4.7K/min.
Pull down rate 5.2 K/min. 4.0 K/min. 4.2 K/min. 4.1K/min.
Max. allowable heat load Test area temperature: +20℃
3000 W 4500 W
Temp. & humid.
performance *1
Temp. & humid. range +10 to +95℃ / 10 to 98%rh
Humid. fluctuation ±2.5%rh
Max. allowable heat load Test area conditions: +25 to +95℃ /90%rh Test area conditions: + 85℃ /85%rh
350 W 300 W 500 W
Construction
Exterior material 18 Cr-stainless steel plate (Hairline finish)
Test area material 18-8 Cr-Ni Stainless steel plate (BA finish)
Insulation Foamed phenol, glass wool
Heater Nichrome strip wire heater
(1.75 kW×2) (3 kW×2)
Humidifier Sheathed heater
Cooler Plate fin cooler and dehumidifier
Refrigeration unit
System Mechanical cascade and compression refrigeration system
Refrigerator Rotary compressor Scroll compressor
Refrigerator capacity Unit 1: 2.2 kw ×1,
Unit 2: 2.2 kw ×1
Unit 1: 3.0 kw ×1,
Unit 2: 3.0 kw ×1
Unit 1: 3.75 kw ×1,
Unit 2: 3.75 kw ×1
Expansion mechanism Electronic expansion valve
Refrigerant R404A, R508A R404A, R23
Air circulator Sirocco fan
Interface Ethernet
Fittings 100mm cable port (×2), specimen power supply control terminal, condenser filter,
specimen temperature input terminal, time signal (×2), casters with levelling feet (×4)
Capacity 220 L 390 L 680 L 1100 L
Chamber total load resistance 50 kg 80 kg 80 kg 150 kg
Inside dimensions mm (inch) *3 W700×H800×D400
(W27.6×H31.5×D15.8)
W700×H800×D700
(W27.6×H31.5×D27.6)
W850×H1000×D800
(W33.5×H39.4×D31.5)
W1100×H1000×D1000
(W43.3×H39.4×D39.4)
Outside dimensions mm (inch) *3 W900×H1742×D1455
(W35.4×H68.6×D57.3)
W900×H1742×D1705
(W35.4×H68.6×D67.1)
W1050×H1955×D1805
(W41.3×H77.0×D71.1)
W1300×H1955×D2005
(W51.2×H77.0×D78.9)
Weight 390 kg 405 kg 615 kg 700 kg
Utility requirements
Allowable ambient conditions 0 to +40℃ (+32 to +104℉ ) / 75%rh max.
Power
supply *4
200V AC 3φ50/60Hz ─ ─ 63 A 70 A
220V AC 3φ60Hz 38 A *5 38 A *5 58 A 64 A
380V AC 3φ50Hz 24 A *5 24 A *5 28 A 32 A
400V AC 3φ50Hz *5 23 A 23 A 27 A 29 A
Noise level *6 57 dB 58 dB 62 dB 63 dB
Exhaust heat quantity kJ/h (kcal/h) 26600 (6357) 26600 (6357) 39600 (9464) 46800 (11185)
*1: At ambient temperature +20℃ , no specimen. Performance shown above conforms to IEC 60068-3-5:2001 and IEC 60068-3-6:2001.
*2: Temperature rate of change in the temperature range excluding ±10% of max/min. temperature.
*3: Excluding protrusions.
*4: Power supply voltage fluctuation to be ±10% of rated value.
*5: Conforms to CE marking based on EU directives.
*6: Measurements are to be taken in an anechoic room at a height of 1.2m from the floor and a distance of 1m from the chamber front panel
(ISO 1996-1:2003 _ A-weighted sound pressure level).
9
ESPEC High and Low Temperature Damp Heat Test Chamber Model ARU-0680 ARU-1100
System Balanced Temperature Control (BTC) system
Temp. performance *1
Temp. range −45 to +180℃ (−49 to +356℉ )
Temp. fluctuation ±0.3 K
Temp. variation in space 3.0 K
Temp. rate
of change *2
Heat up rate 6.3 K/min. 4.7 K/min.
Pull down rate 4.8 K/min. 4.4 K/min.
Max. allowable heat load 4500 W Test area temperature: +20℃
Construction
Exterior material 18 Cr-stainless steel plate (Hairline finish)
Test area material 18-8 Cr-Ni Stainless steel plate (BA finish)
Insulation Foamed phenol, glass wool
Heater Nichrome strip wire heater (3kW ×2)
Cooler Plate fin cooler
Refrigeration unit
System Mechanical single-stage refrigeration system
Refrigerator Scroll-type compressor
Refrigerator capacity 3.0 kw 3.75 kw
Expansion mechanism Electronic expansion valve
Refrigerant R404A
Air circulator Sirocco fan
Interface Ethernet
Fittings 100mm cable port (×2), specimen power supply control terminal, condenser filter,
specimen temperature input terminal, time signal (×2), casters with levelling feet (×4)
Capacity 680 L 1100 L
Chamber total load resistance 80 kg 150 kg
Inside dimensions mm (inch) *3 W850×H1000×D800 (W33.5×H39.4×D31.5) W1100×H1000×D1000 (W43.3×H39.4×D39.4)
Outside dimensions mm (inch) *3 W1050×H1955×D1805 (W41.3×H77.0×D71.1) W1300×H1955×D2005 (W51.2×H77.0×D78.9)
Weight 505 kg 595 kg
Utility requirements
Allowable ambient conditions 0 to +40℃ (+32 to +104℉ ) / 75%rh max.
Power
supply *4
200V AC 3φ50/60Hz 53 A 56 A
220V AC 3φ60Hz 49 A 52 A
380V AC 3φ50Hz 23 A 25 A
400V AC 3φ50Hz *5 22 A 23 A
Noise level *6 61 dB 62 dB
Exhaust heat quantity kJ/h (kcal/h) 32400 (7743) 39600 (9464)
TEMPERATURE CHAMBER
ARU −45 to +180℃
*1: At ambient temperature +20℃ , no specimen. Performance shown above conforms to IEC 60068-3-5:2001.
*2: Temperature rate of change in the temperature range excluding ±10% of max/min. temperature.
*3: Excluding protrusions.
*4: Power supply voltage fluctuation to be ±10% of rated value.
*5: Conforms to CE marking based on EU directives.
*6: Measurements are to be taken in an anechoic room at a height of 1.2m from the floor and a distance of 1m from the chamber front panel
(ISO 1996-1:2003 _ A-weighted sound pressure level).
10
ESPEC High and Low Temperature Damp Heat Test Chamber Model ARG-0220 ARG-0390 ARG-0680 ARG-1100
System Balanced Temperature Control (BTC) system
Temp. performance *1
Temp. range −75 to +180℃ (−103 to +356℉ )
Temp. fluctuation ±0.3 K
Temp. variation in space 3.0 K
Temp. rate
of change *2
Heat up rate 6.0 K/min. 5.0 K/min. 6.0 K/min. 4.7K/min.
Pull down rate 5.2 K/min. 4.0 K/min. 4.2 K/min. 4.1K/min.
Max. allowable heat load
Test area temperature: +20℃
3000 W 4500 W
Construction
Exterior material 18 Cr-stainless steel plate (Hairline finish)
Test area material 18-8 Cr-Ni Stainless steel plate (BA finish)
Insulation Foamed phenol, glass wool
Heater
Nichrome strip wire heater
(1.75 kW×2) (3 kW×2)
Cooler Plate fin cooler
Refrigeration unit
System Mechanical cascade refrigeration system
Refrigerator Scroll-type compressor
Refrigerator capacity Unit 1: 2.2 kw ×1,
Unit 2: 2.2 kw ×1
Unit 1: 3.0 kw ×1,
Unit 2: 3.0 kw ×1
Unit 1: 3.75 kw ×1,
Unit 2: 3.75 kw ×1
Expansion mechanism Electronic expansion valve
Refrigerant R404A, R508A R404A, R23
Air circulator Sirocco fan
Interface Ethernet
Fittings 100mm cable port (×2), specimen power supply control terminal, condenser filter,
specimen temperature input terminal, time signal (×2), casters with levelling feet (×4)
Capacity 220 L 390 L 680 L 1100 L
Chamber total load resistance 50 kg 80 kg 80 kg 150 kg
Inside dimensions mm (inch) *3 W700×H800×D400
(W27.6×H31.5×D15.8)
W700×H800×D700
(W27.6×H31.5×D27.6)
W850×H1000×D800
(W33.5×H39.4×D31.5)
W1100×H1000×D1000
(W43.3×H39.4×D39.4)
Outside dimensions mm (inch) *3 W900×H1742×D1455
(W35.4×H68.6×D57.3)
W900×H1742×D1705
(W35.4×H68.6×D67.1)
W1050×H1955×D1805
(W41.3×H77.0×D71.1)
W1300×H1955×D2005
(W51.2×H77.0×D78.9)
Weight 385 kg 400 kg 615 kg 700 kg
Utility requirements
Allowable ambient conditions 0 to +40℃ (+32 to +104℉ ) / 75%rh max.
Power
supply *4
200V AC 3φ50/60Hz ─ ─ 63 A 70 A
220V AC 3φ60Hz 38 A *5 38 A *5 58 A 64 A
380V AC 3φ50Hz 24 A *5 24 A *5 28 A 32 A
400V AC 3φ50Hz *5 23 A 23 A 27 A 29 A
Noise level *6 57 dB 58 dB 62 dB 63 dB
Exhaust heat quantity kJ/h (kcal/h) 26600 (6357) 26600 (6357) 39600 (9464) 46800 (11185)
TEMPERATURE CHAMBER
ARG −75 to +180℃
*1: At ambient temperature +20℃ , no specimen. Performance shown above conforms to IEC 60068-3-5:2001.
*2: Temperature rate of change in the temperature range excluding ±10% of max/min. temperature.
*3: Excluding protrusions.
*4: Power supply voltage fluctuation to be ±10% of rated value.
*5: Conforms to CE marking based on EU directives.
*6: Measurements are to be taken in an anechoic room at a height of 1.2m from the floor and a distance of 1m from the chamber front panel
(ISO 1996-1:2003 _ A-weighted sound pressure level).
11
Model 0680 1100
Shelf size (mm) W667
D350
W667
D650
W817
D750
W1067
D950
Shelf weight 2 kg 3 kg 6 kg 12 kg
Shelf load capacity
(evenly distributed load) 30 kg 30 kg 40 kg 50 kg
Shelf support max. load
(Including shelf weight) 50 kg 80 kg 80 kg 100 kg
● Control circuit overcurrent protection
● Control circuit short circuit protection cartridge fuse
● System error
● Reverse-prevention relay
● Thermal fuse
● Temperature switch for air circulator
● Air circulator short circuit protection
● Ambient temperature input burn-out detection circuit
● Dry-bulb temperature input burn-out detection circuit
● Specimen temperature input burn-out detection circuit
(only when using specimen temperature control)
● Condenser fan short circuit protection
● Condenser fan overload protection
● Refrigerator temperature sensor burned detect circuit
● Refrigerator short circuit protection
● Refrigerator overcurrent protection
● Refrigerator discharge pipe temperature switch (0680/1100)
● Refrigerator high (low) pressure switch
● Refrigerator frost detection cicuit (0680/1100)
● Refrigerator circuit temperature range over
● Refrigerator frost trouble detection temperature switch
(ARS-0680/1100, ARG-0680/1100)
● Refrigerator discharge pipe temperature trouble detection circuit
(ARS, ARG)
● Heater (humidifier) leak current protection
● Wet bulb temperature input burnout detection circuit
(ARL, ARS)
● Humidifier boil-dry protector (ARL, ARS)
● Humidifier water level detector (ARL, ARS)
● Water tank empty switch (ARL, ARS)
● Water tank low level switch (ARL, ARS)
● Dry wick detection (ARL, ARS)
● Overheat protector
● High deviation temperature alarm
(built into temperature and humidity controller)
● High/ low absolute temperature (humidity) alarms
(built into temperature and humidity controller)
● Specimen power supply control terminal
● Chamber door switch
ACCESSORIES SAFETY DEVICES
SHELVES SIZE AND LOAD RESISTANCE
● Cable port rubber plug (φ100 mm) 2 each
● Shelf brackets 1 set
stainless steel plate (18-8 Cr-Ni stainless steel)
● Shelf 1
stainless steel wire (18-8 Cr-Ni stainless steel)
● Door key 2
● Cartridge fuse (Class B, 250 V 0.4 A, 5 A, 8 A) 1 each
● Wet-bulb wick (ARL, ARS) 1 box (24 wicks)
● Specimen temperature measuring thermocouple (type T, 3m) 1
● Specimen temperature input connector 1
● Operation manual 1
12
OPTIONS
UTILITY TEST SAMPLE SETTING OBSERVATION
Additional cable port
Provided in addition / replacement of
the standard cable ports.
?50 mm diameter
?100 mm diameter
* Each cable port is equipped with a silicone
sponge rubber plug.
Cable port rubber plug
Prevents air leakage from the cable
port.
Portable tank
Power cable
Used to refill the standard tank.
*ARS, ARL only
?2.5 m
?5 m
?10m
*The chamber does not come with a power cable.
Water purifier (WS-1)
Water purifier with reverse osmosis
membrane. Produces approx 6.6L per
hour (at primary water temp. +10℃ ).
Shelf, shelf bracket
Equivalent to standard accessory.
Heavy-duty shelf
Us e d t o hold he av y s p e c i me n s
exceeding the load capacity of the
standard shelf.
Load capacity: 50kg (max. 2 shelves)
*Standard for 1100L model
Viewing window
Used for observation of the specimens
inside the chamber.
Dimensions: W340×H440 mm
NETWORK
Communication cables
?RS-485 5m/ 10m/ 30m
?RS-232C 1.5m/ 3m/ 6m
?GPIB 2m/ 4m
Interface
Computer interface
?RS-485
?GPIB
?RS-232C
Water leak detection system and
dew tray to catch dripping water
are also available to detect and
prevent water damages.
OPTIONS
13
Temperature recorder (digital)
Portable type
−100 to +200℃ 6 dots
Temperature and humidity recorder (digital)
Portable type
−100 to +200℃ / 0 to 100%rh 6 dots
Temperature sensor terminal
Terminal board for dry-bulb temperature sensor in the chamber.
DC output terminal
Outputs temperature, humidity, and
temperature of the specimen from the
test area.
Relay contact output
Up to 8 contacts can be added to the
standard 2 relay contacts (time signals).
Paperless recorder - portable type
Records temperature of each section
such as the temperature inside the
chamber.
Data saving cycle: 5 sec.
External recording media:
CF memory card (256MB)
USB port
Language support: ENG, JPN
[Temperature type]
Temperature range: −100 to +200℃
Number of inputs: Temperature 1
(5 more channels can be turned ON)
[Temperature and humidity type]
Temperature range: −100 to +200℃
Humidity range: 0 to 100%rh
Number of inputs:
Temperature 1 / Humidity 1
(4 more channels can be turned ON)
OPTION
OPTION
OPTION
OPTION
MODE
MODE
SPECIMEN
TEMPERATURE INPUT
(TYPE T)
Temperature input force of the sample
(JIS T)
POWER SUPPLY
CONTROL
FOR SPECIMEN
No.1
No.2
Control output of sample power supply
タイイシグょル output
TIME SIGNALS
ETHERNET
No.6
No.7
No.8
No.10
No.9
タイイシグょル output
TIME SIGNALS
External alarm output
EXTERNAL ALARM
SIGNAL
No.3
No.5
No.4
EXTRA OVERHEAT
PROTECTOR
Add temperature rise prevention device
OVERCOOL PROTECTOR
Temperature overcooling preventer
Temperature inside the tank
(JIS T)
Power output (DC1-5V)
CHAMBER TEMPERATURE
(TYPE T)
MONITOR OUTPUT
(1-5V DC LINEAR)
Record the calculated output
RECORDER OUTPUT
OFF
OPTION
OPTION
OPTION
OPTION
MODE
MODE
SPECIMEN
TEMPERATURE INPUT
(TYPE T)
Temperature input force of the sample
(JIS T)
POWER SUPPLY
CONTROL
FOR SPECIMEN
No.1
No.2
Control output of sample power supply
タイイシグょル output
TIME SIGNALS
ETHERNET
No.6
No.7
No.8
No.10
No.9
タイイシグょル output
TIME SIGNALS
External alarm output
EXTERNAL ALARM
SIGNAL
No.3
No.5
No.4
EXTRA OVERHEAT
PROTECTOR
Add temperature rise prevention device
OVERCOOL PROTECTOR
Temperature overcooling preventer
Temperature inside the tank
(JIS T)
Power output (DC1-5V)
CHAMBER TEMPERATURE
(TYPE T)
MONITOR OUTPUT
(1-5V DC LINEAR)
Record the calculated output
RECORDER OUTPUT
OFF
LOGGING TEST QUALITY
Humidifier delay control
To protect specimens from condensation, humidity control starts after
temperature reaches the set value.
*ARL, ARS only
OPTIONS
Operation manual
Reports & certificates
?CD
?Booklet
?Testing and inspection report
?Test data
?Temperature (& humidity) uniformity
measurement
?Calibration report
?Calibration certificate
?Traceability system chart
?Traceability certificate
Additional overheat protector
Additional preventive measures can be
taken for excessive temperature rise in
the chamber, in addition to the standard
equipped overheat protector.
Overcool protector
If the temperature inside the chamber
decreases excessively, the chamber
stops operating to prevent the specimens from being damaged.
Trouble buzzer
If a trouble occurs, the buzzer will alert
you of the situation.
Rotating signal lamp
The lamp lights up when alarm triggers.
(Available in red or yellow)
External alarm terminal
If the safety device of the chamber is
activated, the external alarm terminal
will notify it to a remote point.
Emergency stop switch
Stops the chamber immediay.
14
Safety precautions
● Do not use specimens which are explosive or flammable,
or which contain such substances.
To do so could be hazardous, as this may lead to fire or
explosion.
● Do not place corrosive materials in the chamber.
If corrosive substances or liquid is used, the life of the unit
may be significantly shortened specifically because of the
corrosion of stainless steel, resin and silicone materials.
● Do not use living organisms or items that exceed the
allowable heat load as a specimen.
● Be sure to read the operation manual before operation.
Safety precautions
● Do not use specimens which are explosive or flammable, or which contain such
substances.
To do so could be hazardous, as this may lead to fire or explosion.
● Do not place corrosive materials in the chamber.
If corrosive substances or liquid is used, the life of the unit may be significantly
shortened specifically because of the corrosion of stainless steel, resin and silicone
materials.
● Do not use living organisms or items that exceed the allowable heat load as a
specimen.
● Be sure to read the operation manual before operation.
Safety precautions
● Do not use specimens which are explosive or flammable, or which
contain such substances.
To do so could be hazardous, as this may lead to fire or explosion.
● Do not place corrosive materials in the chamber.
If corrosive substances or liquid is used, the life of the unit may be
significantly shortened specifically because of the corrosion of stainless
steel, resin and silicone materials.
● Do not use living organisms or items that exceed the allowable heat
load as a specimen.
● Be sure to read the operation manual before operation.
Please contact us for non-standard specification.
Please contact us for non-standard specification.
Please contact us for non-standard specification.
200V AC, 220V AC spec. 380V AC, 400V AC spec.
OPTION
OPTION
OPTION
OPTION
MODE
MODE
SPECIMEN
TEMPERATURE INPUT
(TYPE T)
Temperature input force of the sample
(JIS T)
POWER SUPPLY
CONTROL
FOR SPECIMEN
No.1
No.2
Control output of sample power supply
タイイシグょル output
TIME SIGNALS
ETHERNET
No.6
No.7
No.8
No.10
No.9
タイイシグょル output
TIME SIGNALS
External alarm output
EXTERNAL ALARM
SIGNAL
No.3
No.5
No.4
EXTRA OVERHEAT
PROTECTOR
Add temperature rise prevention device
OVERCOOL PROTECTOR
Temperature overcooling preventer
Temperature inside the tank
(JIS T
)
Power output (DC1)
-5V リニア)
CHAMBER TEMPERATURE
(TYPE T)
MONITOR OUTPUT
(1-5V DC LINEA
R)
Record the calculated output
RECORDER OUTPUT
OFF
OPTION
OPTION
OPTION
OPTION
MODE
MODE
SPECIMEN
TEMPERATURE INPUT
(TYPE T)
Temperature input force of the sample
(JIS T)
POWER SUPPLY
CONTROL
FOR SPECIMEN
No.1
No.2
Control output of sample power supply
タイイシグょル output
TIME SIGNALS
ETHERNET
No.6
No.7
No.8
No.10
No.9
タイイシグょル output
TIME SIGNALS
External alarm output
EXTERNAL ALARM
SIGNAL
No.3
No.5
No.4
EXTRA OVERHEAT
PROTECTOR
Add temperature rise prevention device
OVERCOOL PROTECTOR
Temperature overcooling preventer
Temperature inside the tank
(JIS T)
Power output (DC1-5V)
CHAMBER TEMPERATURE
(TYPE T)
MONITOR OUTPUT
(1-5V DC LINEAR)
Record the calculated output
RECORDER OUTPUT