Drug Trace Moisture Analyzer
Hengteya Pharmaceutical Trace Moisture Analyzer is a high-performance Karl Fischer volumetric method moisture analyzer newly launched by Hengxin Instr
Product details






Hengte YaDrug Trace Moisture AnalyzerIt is a high-performance Karl Fischer volumetric water analyzer newly launched by Hengxin Instrument. After several optimization upgrades, the accuracy and automation level of the product have been greatly improved. The instrument adopts the Karl Fischer volumetric titration principle, contains rich calculation formulas, and corresponding analysis methods. It can quickly and accurately test the moisture content from 10ppm to 100%. It has the function of storing data and can be connected to a printer to print test data. Fully automatic mode, automatic testing, automatic calculation, automatic reagent suction, automatic blank filling, automatic waste liquid discharge, and automatic cleaning. During the titration process, real-time display of the remaining reagent amount and real-time display of potential changes can intuitively reflect the analysis status of the instrument. HTY-C10 complies with multiple national and international moisture determination standards, conforms to pharmacopoeias, and is widely used in industries such as pharmaceuticals, petroleum, power, chemical, pharmaceutical, food, batteries, and testing.



Hengteya Pharmaceutical Trace Moisture AnalyzerTechnical parameters:

model: HTY-C10
Measurement method: Karl Fischer titration method (permanent stop titration)
Moisture range: 10ug—550mg H2O
Measurement range: 0.001%(10ppm)—100%
resolving power: 1ppm
Display mode: 4.3-inch ultra large LCD display screen
Liquid inlet division value: 1ul
Polarization current: ±1000uA
burette: 20ml
Accuracy of burette: 1/20000
Titration linear correlation coefficient: ≥0.999
Mixing speed: Infinitely variable speed
Error range: <1%
Electrode: Double platinum needle electrode, sensitive and faster response
Data storage: 40 items
Printing function: Optional printer
Print content: Ug/ppm/mg/L/sample number/experimenter/date
Drift value blank value deduction: Real time drift measurement function, can be set to deduct or not
Data interface: RS232 interface, capable of connecting peripheral devices such as printers
Special Features: Custom endpoint delay and titration delay; Real time display of current; One click cleaning
Calendar/Clock: Analyze time and date display and print output (without losing power)
External dimensions: 495*330*325mm
Using power supply: Voltage 110-220V, frequency 50HZ
Usage environment: Temperature 2-55 ℃, humidity<90%
Weight: About 8KG



Hengteya Pharmaceutical Trace Moisture AnalyzerConfiguration List:
Serial Number name quantity
1 Karl Fischer moisture analyzer host 1 unit
2 Titration reaction cup component 1 set
3 reagent bottle 3 of them
4 drying bottle 4 of them
5 Connecting lines 13 pieces
6 Burette component 1 set


Hengteya Pharmaceutical Trace Moisture AnalyzerScope of application:

liquid Pharmaceutical industry: raw materials for traditional Chinese and Western medicine, etc
Pesticide industry: soluble powders, emulsions, emulsions, creams, pastes, oils, etc
Petroleum and power industry: insulation oil, transformer oil, hydraulic oil, coal tar, etc
Chemical industry: acids, alcohols, benzenes, phenols, ethers, organic solvents, etc
Other industries: lithium batteries, electrolytes, cosmetics, etc
solid Various solid substances with good solubility, such as inorganic salts, citric acid, freeze-dried powder, and soluble powder
gas Natural gas, liquefied gas, fluorocarbons, butadiene and other gases
Special industries require the use of Karl Fischer heating furnaces
insoluble solid Insoluble solids such as lithium batteries, plastic, metal powders, chemical raw materials, etc., which are prone to contamination and cross contamination of samples (lubricating oils, aldehydes and ketones), samples that are prone to react with Karl Fischer reagent, and samples with slow water release


Hengteya Pharmaceutical Trace Moisture AnalyzerProduct specifications:

1. GB/T 6283-2008 Determination of moisture content in chemical products Karl Fischer method
2. ASTM E1064-2008 Karl Fischer Coulombic Titration for Determination of Water Content in Organic Liquids
3. GB/T 7600-1987 Determination of Moisture Content in Operating Transformer Oil (Coulombic Method)
4. ASTM D4928-00 (2010) Karl Fischer Coulombic Titration for Determination of Water Content in Crude Oil
5. ASTM D6304-2007 Karl Fischer coulometric titration method for determining water content in petroleum products, lubricants, and additives
6. ISO 10337-1997 Determination of Moisture in Crude Oil Karl Fischer Coulombic Titration Method
7. GB/T 11146-2009 Determination of Crude Oil Water Content Karl Fischer Coulombic Titration Method
8. GB/T 3727-2003 Determination of Trace Water in Ethylene and Propylene for Industrial Use
9. GB/T 5074-1985 Method for determination of moisture content in coking products by microcoulometry
10. GB/T 6023-2008 Determination of Trace Water in Butadiene for Industrial Use Karl Fischer Coulombic Method
11. GB/T 7376-2008 Determination of Trace Moisture in Fluoroalkanes for Industrial Use Karl Fischer Method
12. GB/T 18619.1-2002 Determination of Water Content in Natural Gas Karl Fischer Coulombic Method
13. SH/T 0246-1992 Determination of Water Content in Light Petroleum Products (Electricity Method)
14. SH/T 0255-1992 Method for determination of moisture content in additives and lubricating oils containing additives (electric method)
15. ASTM E1064-2008 Karl Fischer Coulombic Titration for Determination of Water Content in Organic Liquids
16. ASTM D4928-00 (2010) Karl Fischer Coulombic Titration for Determination of Water Content in Crude Oil
17. ASTM D6304-2007 Standard for Determination of Water Content in Petroleum Products, Lubricants, and Additives by Karl Fischer Coulombic Titration


Hengteya Pharmaceutical Trace Moisture AnalyzerFunctional features:
1. LCD large screen display, convenient and fast operation interface, eliminating tedious settings, allowing quick access to function pages, and making usage simpler;
2. Imported electromagnetic three-way valve reduces the dead volume rate inside the three-way valve, and the liquid circuit switching speed only takes 0.01 seconds, ensuring testing efficiency;
3. Imported electromagnetic three-way valves avoid the problem of traditional three-way valve leakage, and can withstand pressures up to 100kPa. Even if the pipeline is blocked, there is no need to worry about three-way valve leakage;
4. High precision titration system, with a titration accuracy of up to 1ul;
5. The measurement results and output results comply with GLP standards, can store 40 sets of data, and can be printed with an external printer to obtain test results;
6. The instrument has 5 built-in measurement methods, which can be customized according to different testing requirements for titration speed, titration delay, etc., to meet the testing needs of any sample.
7. Real time display of titration reaction cup current changes, ultra wide current display, allowing for a more intuitive observation of the entire reaction process;
8. Real time drift measurement function, which can monitor drift according to environmental and climate changes at any time, and can set whether to deduct it as needed in the setting method;
9. Automatic solvent suction, automatic blank filling, automatic reagent suction, automatic titration, automatic waste liquid discharge, automatic liquid return, and automatic cleaning functions, simple operation, and no environmental pollution;
10. One click cleaning functions such as startup cleaning and shutdown cleaning, no need for complicated settings, and easier operation;
11. The precision solvent suction pump eliminates the siphon phenomenon caused by air pressure, which stops immediately and accurately controls the volume of solvent;
12. Customize personalized settings: date, sample number, operator number, burette type, measurement method, endpoint current, etc;
13. The fully sealed titration system, corrosion-resistant high borosilicate glass titration cell, and PTFE bottle cap pipeline ensure the personal health of users;
14. A large capacity drying bottle effectively filters moisture from the air, reduces the impact of the environment on test results, and is easy to replace;
15. Under solvent level titration, unique anti reflux device ensures the stability of titration;
16. Low operating noise, almost no sound of mechanical operation during titration process, away from noise troubles;
17. Streamlined appearance design, surface electrostatic spray treatment, anti-corrosion, easy to clean;
18. RS232 interface connects with computers and other devices to achieve networked management.



Hengteya Pharmaceutical Trace Moisture AnalyzerOperation steps:

First assemble the moisture analyzer and connect it to the power supply, then turn on the power switch
Reagent debugging steps:
1. Suck methanol (other co solvents) until the liquid level covers the platinum tip of the electrode
2. Let the instrument perform a blank operation to deduct excess water from methanol (other solvents)
3. Perform multiple calibrations on the Karl Fischer reagent we use (more than 3 times, it is recommended to use deionized water or standard samples for calibration, or standard water samples for calibration)
4. After calibration, sample measurement can be carried out
Sample determination steps:
1. After sampling with an injector, place it on an analytical balance and weigh it. Click to remove the skin
2. Inject the sample into the titration cell
3. Take out the sampler and place it on the analytical balance for weighing. The weight displayed on the balance at this time is the weight of the sample
4. Enter the weight of the sample into the instrument and click to start the measurement
5. The measurement is completed, and the instrument displays the measurement results and automatically stores them


Enjoy a one-year free warranty and lifetime maintenance from the date of purchase;
7-day no reason return and exchange, 24-hour instant response;
One on one technical guidance, allowing you to have no worries after purchasing;
National free consultation hotline: 400-8821-087.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!