YS6080 is a domestically produced desktop grating spectrophotometer independently developed by 3nh company with complete independent intellectual property rights, TFT true color 7-inch capacitive touch screen, full light source, lighting mode: reflection D/8 °, transmission D/0 ° (including UV/exclusion UV measurement), accurate and stable color measurement, large storage capacity, powerful PC expansion function, used for accurate color analysis and transmission in the laboratory.
Technical characteristics of desktop spectrophotometer YS6080
1. High hardware configuration: 7-inch TFT pure color capacitive touch screen; Bluetooth 4.0; Concave grating;
2. Dual array 256 pixel CMOS detector; 4 pulsed xenon lamps;
3. Measure the reflection and transmission spectra of the sample, and the Lab data is accurate, which can be used for color matching and accurate color transfer;
4. Caliber automatic recognition, with four calibers of Φ 25.4/15/8/4mm to switch freely, while taking into account the special needs of customers;
5. Temperature monitoring and compensation, with built-in temperature sensors to monitor and compensate for the testing environment, ensuring more accurate measurement results;
6. The testing wavelength range is 360-780nm, with built-in 400nm cutoff/420nm cutoff/460nm for more professional UV testing;
7. Independent light source detector, constantly monitoring changes in the light source to ensure its reliability;
8. Multiple measurement modes: quality control mode, sample mode, to meet the needs of more customers;
9. Multiple optional accessories: reflective sample clamping tool, transmission fixing bracket, micro hole 4mm transmission fixture, instrument inverted testing fixture, suitable for more working conditions;
10. Large capacity storage space, capable of storing up to 40000 records;
11. Built in camera for framing and positioning;
12. PC software has powerful extension functions.
![]() |
![]() |
![]() |
![]() |
Plastic samples Reflection measurement: using D/8 structure (diffuse illumination, 8 ° direction), in accordance with IS07724/1 CIE, ASTM, DIN, and JIS standards. |
Transmission sample Transmission measurement: using D/0 structure (diffuse illumination, 0 ° direction reception), in compliance with ISO, CIE, ASTM, and DIN standards. |
Measurement of liquid, powder, and solid samples |
measuring aperture Automatic caliber recognition with four different calibers of Φ 25.4/15/8/4mn, allowing for flexible switching and meeting the special needs of customers; |
Application fields of desktop spectrophotometer
Used for accurate color analysis and transmission in the laboratory; Plastic electronics, paint and ink, textile and clothing printing and dyeing, printing, paper products, automotive, medical, cosmetics, and food industries are widely used in color transfer and quality control in scientific research institutions, laboratories, and other industries.
PRODUCT MODEL | YS6080 (Pulse Xenon Lamp) |
Illumination | Reflection: D/8 (diffuse illumination, 8 ° direction reception); SCI/SCE measurement; Including UV/exclusion UV measurement; Transmission: D/0 (diffuse illumination, 0 ° direction reception) SCI/SCE measurement; Including UV/exclusion UV measurement; Haze (ASTM D1003); Complies with the standard CIE No.15, GB/T 3978,GB 2893,GB/T 18833,ISO7724/1,ASTM E1164,DIN5033 Teil7 |
characteristic | Used for accurate color analysis and transmission in the laboratory; Color transfer and quality control of reflective and transparent samples in industries such as plastic electronics, paint and ink, textile and clothing printing and dyeing, and printing. |
Integral sphere size | Φ154mm |
lighting source | 360~780nm xenon lamp, 400nm cut-off xenon lamp, 420nm cut-off xenon lamp, 460nm cut-off xenon lamp |
Spectral method | Concave grating |
a sensor | 256 pixel dual array CMOS image sensor |
Measuring wavelength range | 360~780nm |
wavelength interval | 10nm |
Half bandwidth | 5nm |
Reflectance measurement range | 0~200% |
measuring aperture | Reflection: Φ30mm/Φ25.4mm,Φ18mm/Φ15mm,Φ10mm/Φ8mm,Φ6mm/Φ4mm; Transmission: Φ30mm/Φ25.4mm remarks: 1. Switch caliber automatic recognition 2. Customers can configure the aperture and lens position according to their needs |
Light containing method | Reflective SCI/SCE, transmissive SCI/SCE |
color space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99 |
colour-difference formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter) |
Other chromaticity indicators | WI(ASTM E313,CIE/ISO,AATCC,Hunter), YI(ASTM D1925,ASTM 313), TI(ASTM E313,CIE/ISO), The same color spectral index Mt, Stain fastness, color fastness, strength, coverage Cobalt Platinum Index, Gardner Index 8 degrees glossiness, 555 tone classification, haze (ASTM D1003) |
Observer's perspective | 2°/10° |
Observing light source | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12 |
display | Spectral chart/data, sample chromaticity value, color difference value/graph, color chart, color simulation, qualified/unqualified results, color deviation |
Time | About 2.4 seconds (testing SCI/SCE simultaneously takes about 5 seconds) |
repeatability | Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.06% (400~700nm: within 0.05%): Chromaticity value: Φ 25.4mm/SCI, Δ E * ab standard deviation within 0.012 (after preheating and calibration of the instrument, measure the average value of the whiteboard 30 times at intervals of 5 seconds) Spectral transmittance: Φ25.4mm/SCI, Standard deviation within 0.06% (400~700nm: within 0.06%): Chromaticity value: Φ 25.4mm/SCI, Δ E * ab standard deviation within 0.015 (after preheating and calibration of the instrument, measure the average value of the whiteboard 30 times at intervals of 5 seconds) |
Inter station difference | Φ 25.4mm/SCI, Δ E * ab within 0.12 (average value measured on 12 color plates of BCRA series II) |
size | Length X width X height=370X300X200mm |
weight | About 9.6kg |
Power supply mode | DC 24V, 3A power adapter for power supply |
Lighting source lifespan | More than 500000 measurements in 3 years |
display | TFT true color 7-inch, capacitive touch screen |
interface | USB, Bluetooth ® 4.0, Printing Serial Port |
Store data | 5000 standard samples and 40000 test samples (SCI/SCE count as one data point) |
language | Simplified Chinese, Traditional Chinese, English, (Customizable in German, French, Spanish) |
Operating temperature range | 0~40℃(32~104°F) |
Storage Temperature Range | -20~50℃(-4~122°F) |
Standard accessory | Power adapter, manual, quality management software (official website download), data cable, standard calibration board, transmission black baffle, black calibration box, sample holder, 25.4 caliber, 15 caliber, 8 caliber, 4 caliber, transmission testing fixture components |
Optional Accessories | Micro printer micro hole (4mm) transmission test fixture assembly, instrument inverted test fixture |
Note: | If there are any changes, no further notice will be given |