Product Name: Domestic Drinking Water(CCD)Spectral analyzer Product Model:GNSSZ-DW12NN
Product brand: Zhong'anAolxafe Product Code:
Appearance dimensions:375 mm *400 mm *140mm Net weight:7.4kg
²Test items:pHTurbidity, chromaticityCOD MnPotassium permanganate index, zinc, fluoride, volatile phenols, nitrite, nitrate, cyanide, hexavalent chromium, copper, low concentration manganese, mercury, barium, nickel, lead, cadmium, silver, cleaning agents (anionic surfactants), total iron, calcium, magnesiumwaitMeasurement of indicators.
²Scope of application:Drinking water, etc.
²Application fields:The instrument can be widely used in daily testing of natural mineral water quality for drinking water processing and packaging enterprises, disease prevention and control centers, health supervision departments, and other fields.

Different packages, flexible choices
You can choose packages or customize items according to your needs
²Package 1: Regular8projectpHResidual chlorine, total chlorine, turbidity, chlorine dioxide, ozone, chromaticityCOD MnPotassium permanganate
Index).)
²Package 2: Regular20projectpHResidual chlorine, total chlorine, turbidity, chlorine dioxide, ozone, chromaticityCOD Mn(Potassium permanganate)
Potassium index, nitrate, fluoride, sulfate, volatile phenol, cyanide, hexavalent chromium, low concentration manganese, total iron, mercury, lead
Cadmium, chloride (titration).)
²Package 3: Regular35projectpHResidual chlorine, total chlorine, turbidity, chlorine dioxide, ozone, chromaticityCOD Mn(Potassium permanganate)
Potassium index, nitrate, fluoride, sulfate, volatile phenol, cyanide, hexavalent chromium, low concentration manganese, total iron, mercury, lead
Cadmium, chloride (titration), nitrite, copper, barium, zinc, ammonia nitrogen, nickel, aluminum, formaldehyde, sulfide, molybdenum, cyanide chloride
Beryllium, total hardness, silver, cleaning agent (anionic surfactant).)
Note: For customized selection of items by customers, please contact our customer service staff for consultation!
|
Test Item |
unit |
measurement range |
detection limit |
|
nitrite |
mg/L |
0.01~0.4 |
0.01 |
|
nitrate |
mg/L |
0.2~5 |
0.2 |
|
fluoride |
mg/L |
0.01~1.2 |
0.01 |
|
sulfate |
mg/L |
2~60 |
2 |
|
volatile phenol |
mg/L |
0.05~6 |
0.05 |
|
pH |
— |
6.5~8.5 |
— |
|
cyanide |
mg/L |
0.01~0.4 |
0.01 |
|
hexavalent chromium |
mg/L |
0.01~1 |
0.01 |
|
copper |
mg/L |
0.05~6 |
0.05 |
|
Low concentration manganese |
mg/L |
0.02~1 |
0.02 |
|
total iron |
mg/L |
0.02~4 |
0.02 |
|
mercury |
mg/L |
0.01~0.6 |
0.01 |
|
barium |
mg/L |
0.2~80 |
0.2 |
|
zinc |
mg/L |
0.02~2 |
0.02 |
|
ammonia nitrogen |
mg/L |
0.05~4 |
0.05 |
|
nickel |
mg/L |
0.01~2 |
0.01 |
|
residual chlorine |
mg/L |
0.01~4 |
0.01 |
|
Total Chlorine |
mg/L |
0.01~4 |
0.01 |
|
turbidity |
NTU |
0.5~200 |
0.5 |
|
aluminium |
mg/L |
0.001~0.2 |
0.001 |
|
lead |
mg/L |
0.1~3 |
0.1 |
|
Chloride (titration) |
mg/L |
10~500 |
10 |
|
Chlorine dioxide |
mg/L |
0.02~5 |
0.02 |
|
formaldehyde |
mg/L |
0.02~1.5 |
0.02 |
|
sulfide |
mg/L |
0.01~1 |
0.01 |
|
ozone |
mg/L |
0.01~2.5 |
0.01 |
|
chroma |
PCU |
5~500 |
5 |
|
molybdenum |
mg/L |
0.2~10 |
0.2 |
|
Cyanide chloride |
mg/L |
0.01~1 |
0.01 |
|
铍 |
mg/L |
0.001~0.1 |
0.001 |
|
Total hardness (titration) |
mg/L |
10~500 |
10 |
|
CODMn(Potassium permanganate index) |
mg/L |
0.1~10 |
0.1 |
|
cadmium |
mg/L |
0.01~1 |
0.01 |
|
silver |
mg/L |
0.01~1 |
0.01 |
|
detergent |
mg/L |
0.1~10 |
0.1 |

Keyboard+Touch Dual Input Mode
Beautiful, convenient, and practical

8Inch color touch screen, fully Chinese display interface
Humanized interface design, easy to operate

equipUSB/RS232/vehicle power supply/network/audio interface
Strong scalability, convenient for equipping mobile detection vehicles

Embedded micro printer
Direct printing, clear handwriting

|
²Transmittance accuracy |
±1.0% |
|
²Transmission density repeatability |
≤0.5% |
|
²Number of measurement channels |
12a |
|
²light source |
Tungsten halogen lamp |
|
²optical system |
Beam, diffraction grating |
|
²Spectral bandwidth |
4nm |
|
²detector |
ImportCCD |
|
²wavelength range |
360-900nm |
|
²Wavelength accuracy |
±1nm |
|
²baseline flatness |
±0.005Abs |
|
²RS232/audio/network/VGA/HDMIinterface |
one each |
|
²Car power cord interface |
1 piece |
|
²USBinterface |
6 of them |
|
²WIFIfunction |
support |
|
²Instrument dimensions |
375 mm×400 mm×140mm |
|
²Net weight |
7.4kg |
|
²power supply |
AC:220V±10%,50Hz/60Hz; DC: 12V, 2.5A (optional) |
|
serial number |
name |
Specifications/model |
unit |
quantity |
|
1 |
Drinking Water(CCD)spectrum analyzer |
GNSSZ-DPW12NN |
Taiwan |
1 |
|
2 |
power adapter |
19V/10A |
a |
1 |
|
3 |
data cable |
USB |
item |
1 |
|
4 |
optical disc |
Online software |
Zhang |
1 |
|
5 |
Instrument User Manual |
—— |
copy |
1 |
|
6 |
Warranty Card/Certificate of Conformity |
—— |
Zhang |
1 |
|
7 |
hostbox |
desktop |
a |
1 |
Note: One set of experimental equipment is included as a gift. Different models of experimental equipment may vary when purchased. Please contact customer service for more information on the related complimentary equipment.