The DMS2/DMZ2 series dehumidifier dryer needs to be combined with the drying hopper HD, which can widely correspond to basic equipment ranging from general plastic products to high-end plastic product forming. It can be connected to the forming machine in any way, such as direct connection or centralized drying.
model |
DMZ2-40A |
DMZ2-80A |
DMZ2-120A |
DMZ2-170A |
DMZ2-240A |
DMZ2-500A |
DMZ2-700A |
DMZ2-900A |
||
rotor form |
Honeycomb rotor |
|||||||||
Average dew point of dry air |
℃ |
-40 |
||||||||
drying temperature |
℃ |
80~130(180) |
||||||||
control |
Dry temperature adjustment |
PID control |
||||||||
Regenerative temperature control |
PID control |
|||||||||
Alarm and protection circuit |
Overheating (drying regeneration) |
|||||||||
Motor overload | ||||||||||
Motor reverse prevention | ||||||||||
Cooling delay when stopping | ||||||||||
cooling water flow |
L/min |
6 |
6 |
10 |
15 |
20 |
40 | 60 | 100 | |
power supply |
power supply voltage |
V |
AC 200/380V 50Hz 3P |
|||||||
Capacity of power air switch |
200V |
20A(20A) |
32A(40A) |
40A(50A) |
60A(75A) |
100A(100A) |
125A(125A) | 175A(200A) | 225A(125A) | |
380V |
10A(16A) |
16A(20A) |
20A(32A) |
30A(40A) |
50A(60A) |
80A(80A) | 100A(100A) | 125A(125A) | ||
Product weight |
kg |
120 |
160 |
200 |
345 |
362 |
690 | 900 | 1100 | |
equipment |
W |
mm |
440 |
500 |
786 |
820 | 1425 | |||
D |
mm |
570 |
704 |
885 |
1285 | 1695 | 1477 | |||
H |
mm |
1410 |
1410 |
1817 |
2226 |
|||||
| model | DMS2-40A |
DMS2-80A |
DMS2-120A |
DMS2-170A |
DMS2-240A |
DMS2-350A |
DMS2-500A |
| Rotor form, average dew point of dry air, ℃ drying temperature, ℃ control drying temperature, regeneration temperature control alarm, protection circuit cooling water volume, L/min power supply voltage, V power supply air switch capacity, 200V, 380V product weight, kg equipment size, WmmDmmHmm | Honeycomb rotor |
||||||
-20 | |||||||
80~130(180) | |||||||
PID control | |||||||
PID control | |||||||
Overheating (drying regeneration) | |||||||
Motor overload | |||||||
Motor reverse prevention | |||||||
Cooling delay when stopping | |||||||
6 |
10 |
15 |
20 |
30 |
40 |
||
AC 200/380V 50Hz 3P | |||||||
20A(20A) |
20A(32A) |
32A(40A) |
40A(50A) |
50A(63A) |
100A(125A) |
125A(150A) |
|
10A(10A) |
10A(16A) |
16A(20A) |
20A(32A) |
32A(40A) |
50A(75A) |
60A(100A) |
|
120 |
120 |
130 |
160 |
200 |
368 |
398 |
|
440 |
500 |
786 |
|||||
570 |
704 |
885 |
|||||
1410 |
1410 |
1817 |
|||||
Key Features:
Provide continuous low dew point dehumidification air at -40 ℃, which avoids non drying time and provides continuous and efficient drying air compared to the 1-tower system.
No need for compressed air from the outside, let alone any other special equipment.

stable performance
Using honeycomb rotors as dehumidification sources to provide dry hot air with stable dew point.
We have adopted honeycomb rotors with over 20 years of practical experience, high technical content, and high reliability.
Save energy
Realizing energy savings and driving the trend of dehumidifiers and dryers. (Compared with the ventilated dryer, it saves about 30% of electricity consumption)
Easy maintenance/upkeep can be opened from the front, making it convenient for repairs and cleaning of filters.